Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 4

Liczba wyników na stronie
Pierwsza strona wyników Pięć stron wyników wstecz Poprzednia strona wyników Strona / 1 Następna strona wyników Pięć stron wyników wprzód Ostatnia strona wyników

Wyniki wyszukiwania

help Sortuj według:

help Ogranicz wyniki do:
Pierwsza strona wyników Pięć stron wyników wstecz Poprzednia strona wyników Strona / 1 Następna strona wyników Pięć stron wyników wprzód Ostatnia strona wyników
Since they often inhibit abundant bacteriological populations in municipal wastewater treatment plants, alternative treatment methods should be investigated – including advanced oxidation processes. This paper studies the degradation of three representatives of phenolic compounds using the Fenton system in the presence of chlorides and sulfates: phenol, 2-chlorophenol and 2-nitrophenol. The presence of anions influenced degradation rates of all studied compounds, which is attributed to the reduction in hydroxyl radical generation due to the formation of iron-complexes as well as the formation of much less reactive inorganic radicals. Differences between degradation rates of studied compounds and their degradation products in comparison to the rates observed for pure components show higher resistance of formed intermediates in comparison to phenol or 2-nitrophenol. Additionally, it was found that present anions influence further biodegradation of phenolic compounds but not similarly for all the compounds.
Volatile fatty acids (VFAs) are present in environmental waters in the range of 1 to 5,000 ppm and different methods have been reported for their determination. In this paper we have studied and compared analytical performance parameters for the distillation method followed by potentiometric titration, spectrophotometric and gas chromatographic methods. The main disadvantage of the distillation approach was quite poor absolute recovery (53-58%) from the given matrix and rather elevated limit of quantification (LOQ) at 110 mg/L. Direct potentiometric titration was characterized by acceptable accuracy (above 97%) and precision in the range 1.8%-15%. The LOQ value was 11 mg/L. The spectrophotometric method was sensitive for hydrogen carbonate alkalinity and phosphate ions; measured concentrations of acetic acid were lower than nominal. The precision and accuracy of the spectrophotometric method were in the ranges 1.3-14% and 82.1-104.2%, respectively. Limit of quantification was 28 mg/L. However, if ion exchange bed is used prior to this method the LOQ can be reduced to 5 mg/L. The GC method is characterized by quite low LOQ (5 mg/L) and seems to be the best methodology to determine low VFA concentrations in environmental waters. The precision of the method ranged from 5.7 to 14.8% and accuracy was above 92%. Additionally, this method allows for determination of individual VFAs.
Pierwsza strona wyników Pięć stron wyników wstecz Poprzednia strona wyników Strona / 1 Następna strona wyników Pięć stron wyników wprzód Ostatnia strona wyników
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.