Ograniczanie wyników

Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 23

Liczba wyników na stronie
Pierwsza strona wyników Pięć stron wyników wstecz Poprzednia strona wyników Strona / 2 Następna strona wyników Pięć stron wyników wprzód Ostatnia strona wyników

Wyniki wyszukiwania

Wyszukiwano:
w słowach kluczowych:  relative humidity
help Sortuj według:

help Ogranicz wyniki do:
Pierwsza strona wyników Pięć stron wyników wstecz Poprzednia strona wyników Strona / 2 Następna strona wyników Pięć stron wyników wprzód Ostatnia strona wyników
1
100%
Effect of relative humidity on shear modulus of particleboard. The effect of relative humidity on the shear modulus of particleboard was presented in the paper. Panel specimens were conditioned at 55, 65, 75, 85 and 95% RH. The moisture content and shear modulus of particleboard were determined on these specimens by the twisted square piate method. The relationships between the shear modulus and the moisture content of particleboard and relative humidity were defined.
Three types of alpine plant species,Carex montis-everestii,Quercus aquifolioidesandStipa capillacea, along an altitudinal gradient of 3005–5025 m on the Tibetan Plateau, were chosen to test the generality of the hypothesis that foliar carbon isotope composition (δ¹³C) of C3 plants increases significantly with altitude and to determine climate drivers shaping its altitudinal pattern. Temperature and relative humidity showed significantly negative correlations with altitude; however, precipitation and soil water potential remained unchanged with altitude. Foliar δ¹³C of C. montis-everestii,Q. aquifolioides,S. capillaceaalone or combined together did not significantly increase with altitude, which does not support the leading hypothesis of increased foliar δ¹³C with altitude. There was no difference in foliar δ¹³C among all three species. Multi-factor correlation analyses showed that temperature, precipitation and relative humidity alone did not affect foliar δ¹³C ofC. montis-everestiiandS. capillacea, but conferred significant effects on foliar δ¹³C of Q. aquifolioides.
The effects of the growing season climatic factors (i.e., temperature, precipitation, vapor pressure and relative humidity) on the growing season maximum normalized difference vegetation index (MNDVI), which can mirror the aboveground net primary production and the vegetation maximum absorbed ability of photosynthetically active radiation, were examined during the period from 2000 to 2012 on the Tibetan Plateau. The effects of climatic factors on the MNDVI changed with vegetation types, which was probably due to the fact that the changes of climatic factors differed with the type of vegetation. There was a significant increasing trend for the spatially averaged MNDVI of the vegetation area over the entire plateau. Approximately 16 and 3% of the vegetation area demonstrated a significant MNDVI increasing and decreasing trend, respectively. The MNDVI was significantly affected by relative humidity and vapor pressure, but not affected by temperature and precipitation over the entire plateau. Our findings suggested that the environmental humidity played a predominant role in affecting the variation of MNDVI over the entire Tibetan Plateau.
The occurrence of forest fires is frequent phenomenon in Greece, especially during the warmest period of the year, the summer. Timely and reliable estimation of the meteorological risk for their onset is of crucial importance for their prevention. Thus, the purpose of our current work was firstly the estimation of the values of a suitable relevant index for Greece, meteorological forest fire risk index (MKs,t), derived from actual air temperature (T) and relative humidity data (RH) as well as from regressed T and RH, in a mountainous region (MR) of Nafpaktia, Greece, for the most dangerous period of the year (July-August) and day (11:00 h -16:00 h), for five successive years (2006-2010) and secondly the comparison of the two ways of MKs,t values estimation (from actual and regressed T and RH), based on MKs,t classes. Regressed T and RH data were estimated with the aid of simple linear regression models from T and RH data, respectively, of an urban region, 175 Km away from MR, taking into account firstly the warmest (2007) and the coldest (2006) year of the examined year period. It was confirmed that MKs,t values (based on regressed T and RH data) coincided in their classification to the respective ones resulted from actual T and RH data, that is, there was absolute success (100%). Using simple linear regression lines and applying them to estimate separately T and RH at MR, for the most dangerous period of year and day concerning the whole examined year period, it was found that almost all the estimated MKs,t values coincided, regarding their classification, with those estimated from actual T and RH data (97% success), which was considered very satisfactory. Therefore, our research methodology contributes a new perspective to a reliable estimation of MKs,t from remote T and RH data using simple statistical models.
The aim of this study is the analysis of relative humidity in timber forest and open area at Kopciowa, near Krynica Zdrój in Beskid Sądecki Mountains. The data comes from psychrometric measurements from 1971-1982, which were collected at the Phytoclimatic Research Station of the Department of Forest Climatology. The lowest values of relative humidity were spring, on average 80% on open area and 85% in timber forest. The highest values were autumn, properly 91% on open area and 94% under forest canopy. In all time periods fluctuations of relative humidity they were small in forest. In individual seasons of year and in vegetation period also, the relative humidity was greatest in forest. The biggest differences, on benefit of forest stand, were in spring months (April, May), the smallest differences were in November and December, and they were on average 4%. The differences of relative humidity for decade periods were between 8 and 15%, in pentad periods from 15 to 30% and in individual days they achieved 50% even.
The aim of this study is the analysis of multiannual changeability of air relative humidity in Forest Experimental Station in Krynica Zdrój. The data comes from measurements from 1971­2006, which were collected at the Phytoclimatic Research Station of the Department of Forest Climatology in Mochnaczka Wyzna (718 m a.s.l.) and meteorological station in Krynica Zdrój health resort (580 m a.s.l.) also Jaworzyna Krynicka summit (1113 m a.s.l.). The long-term mean annual air relative humidity was 84.9% with deviation of 2.4%. The highest long-term mean monthly sum of the air relative humidity falls to December (92.5%), and the lowest falls to May: 76.8%. The air relative humidity trend index has totaled -6.1% in multiannual 1971-2006. Five-year forecast has exerted negative trend of air relative humidity on Forest Experimental Station in Krynica Zdrój.
Celem pracy było określenie stabilności właściwości mechanicznych ciastek biszkoptowych w czasie przechowywania. Wykazano zmiany odporności ciastek biszkoptowych na działanie siły ściskającej w zależności od wilgotności względnej środowiska i czasu przechowywania. Stwierdzono znaczące zmiany właściwości mechanicznych ciastek przy niewielkich zmianach ich aktywności wody.
Celem pracy była analiza kształtowania się wilgotności względnej powietrza w łazience żelbetowego budynku prefabrykowanego podczas mycia się w umywalce, kąpieli pod natryskiem lub w wannie, prania w pralce automatycznej i suszenia odzieży. Wilgotność względną powietrza oceniano za pomocą miernika mikroklimatu MM-01 z zespołem sond zawieszonych w połowie wysokości pomieszczenia. Badany wskaźnik higrometryczny najbardziej wzrósł (to jest aż o 26,0%) podczas kąpieli pod natryskiem i wyniósł 63,3%. Nie została jednak przekroczona wartość progowa 70%, sprzyjająca namnażaniu się trudnych do likwidacji grzybów pleśniowych.
W pracy porównano warunki wilgotnościowe powietrza na terenie Obserwatorium Agro- i Hydrometeorologii Wrocław-Swojec w okresie pięcioletnim (2004-2008). Analizowano dekadowe wartości niedosytu wilgotności i wilgotności względnej powietrza. Pomiary klasyczne wykonywano za pomocą psychrometru Augusta umieszczonego w klatce meteorologicznej na wysokości 2 m nad glebą. Średnią dobową obliczano na podstawie trzech pomiarów terminowych (godz. 7, 13 i 19 CET) dla niedosytu wilgotności powietrza i czterech pomiarów (godz. 1, 7, 13 i 19) dla wilgotności względnej powietrza; wartości z godziny 1 odczytywano z termohigrografu dobowego. Automatyczna stacja meteorologiczna firmy Campbell Sci. Ltd. (model CR23X), której czujnik wilgotności umieszczony był w tej samej klatce meteorologicznej, była zaprogramowana na zapisywanie raportów godzinnych, z których to wartości obliczano średnie dobowe, a następnie dekadowe. Wartości niedosytu wilgotności powietrza uzyskane metodą klasyczną były niemal zawsze wyższe od wartości ze stacji automatycznej, a wilgotności względnej niższe. Analiza regresji liniowej potwierdziła ścisły związek wartości uzyskanych dwoma metodami (współczynnik korelacji r > 0,96), a testy statystyczne wykazały, że w przypadku niedosytu wilgotności powietrza zdecydowana większość wyników pomiarów wykonanych tymi metodami różniła się istotnie.
Pierwsza strona wyników Pięć stron wyników wstecz Poprzednia strona wyników Strona / 2 Następna strona wyników Pięć stron wyników wprzód Ostatnia strona wyników
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.