This paper presents the results of the triaxial tests performed on medium sand and sandy clay samples. The shear strength and deformation characteristics from consolidated drained (CD) tests performed in a controlled saturation state were determined. The study was conducted in a modern apparatus for triaxial testing of unsaturated samples. Test specimens with a diameter of 70 mm and height of 140 mm were prepared by compaction in a laboratory in a special form. The main aim of this study was to investigate the effect of matric suction on the shear strength and deformation characteristic of medium sand and sandy clay. The axis translation technique was used to apply matric suction to soil specimens.
Wyznaczenie geotechnicznych warunków posadowienia obiektów budowlanych obejmuje profesjonalne badania terenowe i laboratoryjne gruntu. W praktyce inżynierskiej coraz bardziej popularnym urządzeniem stosowanym do badań terenowych podłoża gruntowego jest sonda statyczna CPTU. Wytyczne i zalecenia dotyczą tylko sondy o powierzchni stożka 10 cm², ale dopuszczają też do użycia m.in. sondę o powierzchni stożka 15 cm². W przypadku wykorzystywania stożków CPTU o różnych rozmiarach pojawia się problem wpływu wielkości sondy na uzyskiwane w trakcie sondowania wyniki. W artykule przedstawiono oraz przeanalizowano wyniki uzyskane w trakcie badań dwiema końcówkami piezometrycznymi: standardową o powierzchni stożka 10 cm² oraz sondą o powierzchni stożka 15 cm².