Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 1

Liczba wyników na stronie
Pierwsza strona wyników Pięć stron wyników wstecz Poprzednia strona wyników Strona / 1 Następna strona wyników Pięć stron wyników wprzód Ostatnia strona wyników

Wyniki wyszukiwania

Wyszukiwano:
w słowach kluczowych:  3-methyl histidine
help Sortuj według:

help Ogranicz wyniki do:
Pierwsza strona wyników Pięć stron wyników wstecz Poprzednia strona wyników Strona / 1 Następna strona wyników Pięć stron wyników wprzód Ostatnia strona wyników
The present study deals with the application ofhigh-perform ancc-liquid-chromatographyl(HPLC) method for a quantitative detection of carnosine, anserine, L-histidine and 3-methyl-L-histidine in biological material with o-phthaldialdehyde (OPA) post column derivatisation at the constant temperature of 50°C. For this purpose, some mobile-phases were prepared with scalar acetonitrile concentrations. A complete separation of all molecules, particularly for carnosine and 3-methyl-L-his- tidine, was obtained with a solution of acetonitrile and 6mM hydrochloric acid with 0.48 M sodium chloride (5%:95% v/v). Post column derivatisation reaction at temperature of 50°C permitted to obtain an increase in sensibility of all molecules. This method has been utilised for detection of histidine dipeptides in boar spermatozoa and in sheep milk. Concentrations (mean ± S.E. nmol/109 spermatozoa) of carnosine (0.96 ± 0.14) and anserine (0.83 ± 0.18) in boar spermatozoa were significantly lower than those of L-histidine (52.85 ± 4.86) and 3-methyl-L-histidine (83.07 ± 7.1). Positive correlation was found between carnosine and anserine contents (r=0.740; p<0.01) and between L-histidine and 3-methyl-L-histidine (r=0.657; p<0.01). All histidine dipeptides studied were also present in 40 samples of sheep milk. In a case of samples without unit-forming colonies (UFC) of Staphylococcus coagulase-positive, carnosine concentrations (9.17 ±0.89 nmol/ml) were higher than anserine (0.51 ±0.02 nmol/ml) and both were significantly lower in respect to L-histidine (49.51 ± 6.48 nmol/ml) and 3-metyl-L-histidine (81.21 ±6.82 nmol/ml). A negative correlation was observed between carnosine milk levels (r=-0.773; p<0.01) and UFC/ml of Staphylococcus coagulase-positive. In conclusion this very simple and fast method can be used to detect histidine dipeptides in biological compartments where their concentrations are very low.
Pierwsza strona wyników Pięć stron wyników wstecz Poprzednia strona wyników Strona / 1 Następna strona wyników Pięć stron wyników wprzód Ostatnia strona wyników
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.