Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 17

Liczba wyników na stronie
Pierwsza strona wyników Pięć stron wyników wstecz Poprzednia strona wyników Strona / 1 Następna strona wyników Pięć stron wyników wprzód Ostatnia strona wyników

Wyniki wyszukiwania

help Sortuj według:

help Ogranicz wyniki do:
Pierwsza strona wyników Pięć stron wyników wstecz Poprzednia strona wyników Strona / 1 Następna strona wyników Pięć stron wyników wprzód Ostatnia strona wyników
The widespread East European millipede Brachyiulus jawlowskii is being reported from Poland for the first time, currently representing the northwesternmost record.
The purpose of this study was to examine the safety of the long-term application of QuikClot Combat Gauze, ChitoGauze PRO and Celox Gauze using a swine model. The study was conducted on nine pigs weighing approximately 30 kg, which were randomly divided into three groups. Under deep anesthesia, the pigs underwent complete transverse cutting of the femoral artery in the groin region. Hemostatic dressings were left in the wound for 24 hours. The animals were euthanized 24 hours after dressing application. In each group, macroscopic and microscopic severe changes and shock symptoms were observed in the lungs, liver, kidneys and heart. Fibrino-gaseous embolic material was found in the pulmonary artery of each group and in the lung vessels of the animals from the ChitoGauze PRO and Celox Gauze groups. In conclusion, the long-term application of the evaluated hemostatic dressings has the risk of coagulopathy and reaching the progressive stage of shock. The residues from the hemostatic dressings can ingress into the systemic circulation, thereby increasing the risk of embolus formation. Because of these harmful effects, the evaluated hemostatic dressings are not appropriate for long-term use. Future studies are needed on the consequences of the long-term application of these hemostatic agents.
The objective of this study was to determine the response of hemostatic dressings. Coagulation and fibrinolytic systems, red blood cell parameters, platelet and leukocyte counts were evaluated after the application of hemostatic dressings: QuikClot, Chitoauze and Celox gauze. The experiment was performed on ten pigs
The effectiveness of three types of hemostatic dressings, QuikClot Gauze, ChitoGauze PRO and Celox Gauze, was evaluated in nine pigs. The results indicated a strong influence of all examined dressings on porcine femoral muscle tissue evaluated 24 hours after direct contact. A histopathological analysis revealed pathological changes in muscle tissue specimens collected from all the animals.
The aim of this study was to evaluate the suitability of thromboelastometry for the analysis of blood test results in goats after the use of hemostatic dressings to control massive bleeding. The study was carried out on 12 goats, 6 animals in each of two subgroups. In all experimental animals incision of the femoral artery was performed, and bleeding was controlled with QuikClot gauze in the first group and Celox gauze in the second group. Dressings were applied for 60 minutes. Blood samples for thromboelastometry were collected from the jugular vein before the incision and 60 min after the application of a dressing. Clotting time (CT), clot formation time (CFT), maximum clot firmness (MCF) and α angle (°) were measured in three standard ROTEM assays (system with generation of reaction curve, numerical parameters and size of the blood clot): intrinsic coagulation pathway (INTEM), extrinsic coagulation pathway (EXTEM) and functional fibrinogen (FIBTEM). Complete hemostasis of the injured femoral artery was found in all goats. No significant differences between pre- and post-incision thromboelastometric parameters were found in any tests in any of the groups, which indicates that the use of dressings was not associated with blood coagulation disorders. This study is the first to describe the use of thromboelastometry in goats for the assessment of clot formation and hemostatic disorders.
Pierwsza strona wyników Pięć stron wyników wstecz Poprzednia strona wyników Strona / 1 Następna strona wyników Pięć stron wyników wprzód Ostatnia strona wyników
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.