Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 14

Liczba wyników na stronie
Pierwsza strona wyników Pięć stron wyników wstecz Poprzednia strona wyników Strona / 1 Następna strona wyników Pięć stron wyników wprzód Ostatnia strona wyników

Wyniki wyszukiwania

Wyszukiwano:
w słowach kluczowych:  radiation dose
help Sortuj według:

help Ogranicz wyniki do:
Pierwsza strona wyników Pięć stron wyników wstecz Poprzednia strona wyników Strona / 1 Następna strona wyników Pięć stron wyników wprzód Ostatnia strona wyników
Terrestrial background gamma radiation in urban surroundings depends not only on the content of radionuclides in the soil and bedrock, but also on levels of radionuclides in building materials used for the construction of roads, pavements and buildings. The aim of this study was to characterize an outdoor absorbed dose rate in air in the city of Wroclaw and to indicate factors that affect the background gamma radiation in an urban space. Gamma spectrometric measurements of the radionuclide content and absorbed dose rate in air were performed by means of portable RS-230 gamma spectrometers and at sites with various density of buildings, in the city center and in more distant districts, over pavements and roads as well as in a park, a cemetery and on four bridges. Measurements were performed at a 1-meter height. The absorbed dose rate in air ranged from 19 to 145 nGy h-1, with the mean of 73 nGy h-1. This paper implicates that terrestrial background gamma radiation depends on the type of building material used for the construction of roads and pavements and on the density of buildings shaping the geometry of the radiation source. The highest background gamma radiation was observed in the center of the city, where buildings are situated close to each other (nearly enclosed geometry) and pavements are made of granite. The lowest background gamma radiation was noticed on bridges with nearly open field geometry. Additionally, three profiles at the heights of 0.0, 0.5 and 1.0 m were arranged between two opposite walls of the hall of the Main Railway Station in Wroclaw, where the floor is made of various stone slabs. The results indicated that the absorbed dose rate in air varied, depending on the type of building material, but became averaged along with the height.
The radiation exchange drives the plant ecosystems energy balance and provides the energy for photosynthesis, transpiration and plant growth. The investigation on net radiation and its component during vegetation season in relation to the clearness index and sun elevation in a cultivated 31-year-old mountain spruce [Picea abies (L.) Karst.] stand is presented. Downward short-wave radiation – Sd (incident on the spruce stand was the main part of the short-wave radiation balance during the whole growing season (April–October) 2008. The Sd a mount i s seasonally variable factor determined by the duration of solar shine and the atmosphere transmissivity. Obtained value of net radiation (Rn) and downward short-wave radiation (Sd) ratio amounts to 0.61 on average during the growing season 2008 documenting the importance of the downward short-wave radiation in the net radiation of investigated spruce stand.
Background. X-ray examination is a popular and universally used injury and disease diagnostic method. A distinctive X ray examination feature is that it can be done quickly which is extremely important in case of the need for rapid diagnosis of patients in life threatening condition. Another advantage of the X-ray examinations is also relatively low cost of carry. However, X-ray examination involve adverse health effects. During the examination the patient is subjected to ionizing radiation that might have impact on his health. Objective. The aim of this study has been to determine and assess the size of the entrance surface doses (ESD) received by patients during selected X-ray examinations performed on the basis of the medical working procedures available in healthcare entities in Masovian Voivodeship in Poland. Materials and Method. The examinations were conducted for 71 X-ray units located in the Masovian Voivodeship. Measurements of doses received by the patients were based on our own validated test methods. Results. It was found that the range applied to the high voltage in healthcare entities does not always coincide with the values specified in the standard procedures. It was found in the skull projection radiography AP and LAT that the recorded values were from range 60 to 82 kV (the average value of 74 kV) while in accordance with a standard procedure they should be in the range from 65 to 75 kV. Only in case of cervical spine radiography in the AP projection, the LAT exposure conditions were matching with the standard obligatory procedures in Poland. The consequence of selecting exposure conditions are significant differences in the size of the doses the patient receive during the same medical procedures. The greatest range of ESD doses was found during radiography of the thoracic spine in the projection AP and LAT. The projection LAT measured values were in the range of 523 to 10550 μGy (average value 2175 μGy). Conclusions. It is necessary to update immediately the standard procedures and to develop detailed guidelines for the preparation of working procedures in X-ray rooms.
Studies were carried out to elucidate lipid peroxidation and crypt survival in the small intestinal mucosa of mice pretreated per os with either diethylnitrosamine (DENA) (0.01, 0.1, or 1.0 mg kg/b.w) or normal saline daily for 21 days, and whole-body gamma irradiated (2.5, 5.0. 7.5, or 10;0 Gy) following post-DENA and/or post-saline (control) exposures. Results show that DENA lowered the total value of mean lethal radiation dose for crypt cells, and the agent was enable to sensitize intestinal crypts to y-rays. Present data suggest that gamma radiation- and/or DENA-induced lipid peroxidation and/or pro-oxidant shift(s) is a risk factor for murine crypt survival.
Metodę radiacyjną zastosowano do odkażania substratu torfowego sztucznie zakażonego Sclerotinia sclerotiorum. Użycie dawki 4,5 kGy w 90% hamowało rozwój patogena in vitro, podczas gdy dawka 3 kGy całkowicie inaktywowała sklerocja grzyba. Na fragmentach pędów chryzantem zainokulowanych kulturami patogena traktowanymi 4 różnymi dawkami promieniowania nekroza rozwijała się istotnie szybciej na tkankach roślin zakażonych przez S. sclerotiorum poddanych niższej dawce promieniowania. W testach szklarniowych zastosowanie dawki 10 kGy całkowicie wyeliminowało omawianego patogena z zakażonego podłoża.
Oznaczono stężenie radonu Rn w powietrzu budynków mieszkalnych oraz w piwnicach miasta Olsztyna. Obliczono efektywne równoważniki dawki dla osób zamieszkujących w domach przedwojennych i powojennych zbudowanych z cegieł oraz w domach z wielkiej płyty.
W pracy zbadano plonowanie roślin czterech bardzo wczesnych odmian ziemniaka w zależności od wielkości zastosowanej dawki promieniowania mikrofalowego. Czynnikami doświadczenia były: odmiana ziemniaka (Felka Bona, Rosara, Velox i Lord), czas napromieniowania mikrofalami (5, 10 i 15 s) oraz moc generatora mikrofal (100, 200 i 300 W). Dawka promieniowania, moce generatora oraz czas napromieniania sadzeniaka mikrofalami istotnie modyfikowały plon bulw ziemniaka spod jednej rośliny. Napromienianie sadzeniaków mikrofalami pochodzącymi z generatora działającego z mocą 100 W przez czas 5-15 s powodowało, w odniesieniu do próby kontrolnej, zwiększenie plonu bulw ziemniaka spod jednej rośliny potomnej.
Do doświadczeń wybrano rdestowca ostrokończystego (Reynoutria japonica Houtt.) którego łodygi posiadają obszerne kanały rdzeniowe. Rośliny uprawiane były w warunkach naturalnych. W warunkach naturalnych łodygi rdestowca są ocienione przez liście i rzadko są narażone na bezpośrednie oświetlenie promieniowaniem słonecznym. Badania wykazały, że w kanałach rdzeniowych rdestowa w ciągu nocy stężenie CO2 może przekraczać 10%, a ciągu dnia następuje zmniejszanie tego stężenia nawet poniżej 1%. Zmianom stężenia zawartości CO2 towarzyszą podobne wielkością lecz przeciwnie skierowane zmiany zawartości O2: zmniejszanie się jego zawartości w nocy i zwiększanie w ciągu dnia. Wprowadzenie nadmiernego oświetlenia łodyg doprowadziło do zmian zawartości CO2 i O2. Ze wzrostem intensywności oświetlenia szybciej malała zawartość CO2 i szybciej wzrastała zawartość tlenu w kanałach rdzeniowych. Zmiana warunków świetlnych ułatwiała reasymilację CO2 zgromadzonego w godzinach nocnych przez łodygę. W ciemności uwalnianie tego gazu w kanałach rdzeniowych wynosi około 0,6 µmol CO2·m-2·s-1, a świetlny punkt kompensacyjny reasymilacji uzyskiwano w intensywności napromieniowania około 80 µmol·m-2·s-1. Natomiast świetlne wysycenie reasymilacji notowano przy napromieniowaniu około 850 µmol·m-2·s-1 z intensywnością reasymilacji wynoszącą około 0,9 µmol CO2·m-2·s-1. Badania wykazały że nienaturalnie wysokie dawki promieniowania nie są czynnikiem stresowym dla łodyg rdestowca a wręcz przyczyniają się do szybszego zużywania CO2 i nagromadzania O2.
Pierwsza strona wyników Pięć stron wyników wstecz Poprzednia strona wyników Strona / 1 Następna strona wyników Pięć stron wyników wprzód Ostatnia strona wyników
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.