PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
1995 | 46 | 1 |

Tytuł artykułu

Zastosowanie metody ICP - AES w wielopierwiastkowej analizie wzorca lisci tytoniu

Autorzy

Warianty tytułu

Języki publikacji

PL

Abstrakty

PL
Technika ICP-AES jest prostą i szybką metodą analityczną, która pozwala na bezpośrednią wielopierwiastkową analizę roztworów. W przypadku próbek biologicznych problemem analitycznym jest ich mineralizacja, zwłaszcza przy oznaczaniu pierwiastków występujących w śladowych ilościach.
EN
The metod of the atomic emission spectrometry with an excitation in the inductively coupled plasma ICP-AES has been applied to the simultaneous analysis of the elements: Al, Cd, Cr, Cu, Fe, Li, Mg, Mn, Ni, P, Pb, S, Sr and V in the tobacco leaves samples CTA-OTL-1. The spectrometry analyses have been carried out on the emission spectrometer Spectroflame ICP M. About 300 mg of the sample and 1 cm3 of the concentrated HNO3 acid have been sealed in the quartz tube and mineralized by the pressure method. Since the ICP-AES technique is the most suitable to the direct analysis of the solutions, the main problem to solve was a mineralization of the sample. An application of the HNO3 acid alone did not give satisfactory results - unsolved residue remained. As a consequence the results for Mg, Ni, Pb were too low, whereas for the Al - nearly twice lower than the respective values given in the sample reference data. It has been observed that an addition of the conc. HF acid helps to dissolve the residue and, consequently, the optimalization of the mineralization proces in the presence of the HNO3-HF mixture has been carried out. The results show that the appropriate amount of the HF acid to be added is 0.25 cm3. The other methods of mineralization using various mixtures of acids did not give good results. Only HNO3-HF mixture used in appropriate proportions give results in agreement with provided sample characteristics. The samples after mineralization have been diluted with redestilled water mineralization have been diluted with redestilled water up to 5 cm3. Since the level of concentration of the investigated elements has been very different - the direct determination has been carried out only with respect to Cd, Cr, Ni, Pb and V elements. In order to determine the concentration of the Al, Cu, Fe, Li, Mg, Mn, P, S and Sr the original solution has been diluted ten times i.e. from 1 cm3 to 10 cm3. This method is the most suitable to the analysis of the various powdered materials of plant origin.

Wydawca

-

Rocznik

Tom

46

Numer

1

Opis fizyczny

s.53-57,tab.,bibliogr.

Twórcy

autor
  • Uniwersytet Slaski, Katowice
autor

Bibliografia

Typ dokumentu

Bibliografia

Identyfikatory

Identyfikator YADDA

bwmeta1.element.agro-article-ac3d56b1-dd26-4e74-9ad4-6dac27836032
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.