PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
2014 | 17 | 4 |

Tytuł artykułu

Response of the coagulation system after application of hemostatic dressings in an animal model

Treść / Zawartość

Warianty tytułu

Języki publikacji

EN

Abstrakty

EN
The objective of this study was to determine the response of hemostatic dressings. Coagulation and fibrinolytic systems, red blood cell parameters, platelet and leukocyte counts were evaluated after the application of hemostatic dressings: QuikClot, Chitoauze and Celox gauze. The experiment was performed on ten pigs

Słowa kluczowe

Wydawca

-

Rocznik

Tom

17

Numer

4

Opis fizyczny

p.725-727,ref.

Twórcy

  • Police Academy, Pilsudskiego 111, 12-100 Szczytno, Poland
autor
  • Department of Surgery and Rentgenology, Faculty of Veterinary Medicine, University of Warmia and Mazury in Olsztyn, Oczapowskiego 14, 10-719 Olsztyn, Poland
  • Department of Internal Diseases, Faculty of Veterinary Medicine, University of Warmia and Mazury in Olsztyn, Oczapowskiego 14, 10- 719 Olsztyn, Poland
  • Department of Internal Diseases, Faculty of Veterinary Medicine, University of Warmia and Mazury in Olsztyn, Oczapowskiego 14, 10- 719 Olsztyn, Poland
autor
  • Department of Surgery and Rentgenology, Faculty of Veterinary Medicine, University of Warmia and Mazury in Olsztyn, Oczapowskiego 14, 10-719 Olsztyn, Poland
autor
  • Police Academy, Pilsudskiego 111, 12-100 Szczytno, Poland
  • Department of Surgery and Rentgenology, Faculty of Veterinary Medicine, University of Warmia and Mazury in Olsztyn, Oczapowskiego 14, 10-719 Olsztyn, Poland
  • Department of Surgery and Rentgenology, Faculty of Veterinary Medicine, University of Warmia and Mazury in Olsztyn, Oczapowskiego 14, 10-719 Olsztyn, Poland
autor
  • Police Academy, Pilsudskiego 111, 12-100 Szczytno, Poland

Bibliografia

  • Levi M, De Jonge E, Van der Poll T (2006) Plasma and plasma components in the management of disseminated intravascular coagulation. Best Pract Res Clin Haematol 19: 127-142.
  • Li J, Cao W, Lv XX, Jiang L, Li YJ, Li WZ, Chen SZ, Li XY (2013) Zeolite-based hemostat QuikClot releases calcium into blood and promotes blood coagulation in vitro. Acta Pharmacol Sin 34: 367-372.
  • Marcucci R, Gori AM, Giannotti F, Baldi M, Verdiani V, Del Pace S, Nozzoli C, Abbate R (2006) Markers of hypercoagulability and inflammation predict mortality in patients with heart failure. J Thromb Haemost. 4: 1017-1022.
  • Rall JM, Cox JM, Songer AG, Cestero RF, Ross JD (2013) Comparison of novel hemostatic dressings with QuikClot combat gauze in a standardized swine model of uncontrolled hemorrhage. J Trauma Acute Care Surg 75 (Suppl 2): S150-S156.
  • Travers S, Dubourg O, Ribeiro Parenti L, Lefort H, Albarello S, Domanski L (2012) Prehospital use of haemostatic dressing QuikClot ACS+TM for hemorrhage control of a perineal trauma. Ann Fr Anesth Reanim 31: 969-971.

Typ dokumentu

Bibliografia

Identyfikatory

Identyfikator YADDA

bwmeta1.element.agro-7bb43f17-06e5-4be1-bc93-a71e9210e973
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.