Survey of indoor air pollution and health symptoms at residential buildings

Treść / Zawartość

Warianty tytułu

Języki publikacji

EN

Abstrakty

EN
This survey work summarizes the generation of indoor air pollutants (IAPs) through household products and activities and also the probable health symptoms of IAPs were discussed through questionnaire in the residential buildings of urban and semi urban area when compared to rural (control) area by door to door survey. The IAPs are categorized as physical, chemical and biological and surveyed as per the product(s) usage in the closed room of buildings. The survey results of IAPs generated from household products and activities, these are asbestos, fine particulate matters and ash as physical pollutants. The chemical pollutants are carbon mono and di oxide gases, phthalates; DDT, chlordane, heptachlor, o-phenylphenol; PBDEs, Formaldehyde, Other Aldehydes, lead, benzene, chloroform, para-dichlorobenzene, methylene chloride, perchloroethylene, styrene, benzene, formaldehyde, terpenes, styrene, phthalate esters, toluene, Propellant, pesticides, PAH, NOx, acrylamide, VOCs, acetone, HCl gas and biological pollutants are bacteria, fungi, viruses, house dust mites, animal dander; cockroaches, microbial spore. In respect to established health impact data, the health symptoms were recorded after survey in two areas viz. urban and semi urban area. The health symptoms were recorded as eye, nose, and throat irritation; allergic reactions, respiratory irritation, aggravated asthma, influenza and other infectious diseases may be the generation of IAPs. The urban and semi urban area are compared with rural (control) area in which no symptoms were found as per discussion. In the present survey it was concluded that the generation of IAPs may from household products and activities in the urban and semi urban area due to less ventilation facilities when compared to rural (control) area. This is a preliminary observation, further researches are needed in relation to measurement of physical, chemical and biological indoor pollutants in closed room of residential buildings and also health hazards study of residents by haematological, biochemical, enzymological and genotoxicological parameters.

Wydawca

-

Rocznik

Tom

08

Numer

1

Opis fizyczny

p.17-30,fig.,ref.

Twórcy

autor
  • Department of Environmental Science, University of Calcutta, 51/1 and 2 Hazra Road, Kolkata 700019, India
autor
  • Department of Environmental Science, University of Calcutta, 51/1 and 2 Hazra Road, Kolkata 700019, India
  • Department of Environmental Science, University of Calcutta, 51/1 and 2 Hazra Road, Kolkata 700019, India
autor
  • Department of Environmental Science, University of Calcutta, 51/1 and 2 Hazra Road, Kolkata 700019, India
  • Department of Environmental Science, University of Calcutta, 51/1 and 2 Hazra Road, Kolkata 700019, India

Bibliografia

  • [1] Batterman, S., Bartoletta, N., Burge, H., Proceedings of the 84th Annual Meeting and Exhibition of the air and waste management association (1991) 91-62.9 Vancouver.
  • [2] Bluyssen, P. M. Commission of the European Communities, Directorate-General XI1 for Science, Research and Development (1991).
  • [3] Bluyssen, P. M., de Oliveira Fernandes, E., Fanger, P. O., Groes, L., Clausen, G., Roulet, C. A, Bernhard, C. A. Valbjerrn, O., European Audit Project to Optimize Indoor Air Quality and Energy Consumption in Ofice Buildig, 1995a.
  • [4] Bluyssen, P. M., de Oliveira Fernandes, E., Groes, L., Clausen, G., Fanger, P. O. Albjorn, V., Bernhard, C. A., Roulet, A., Indoor Air 6 (1996) 221-238.
  • [5] Bluyssen P, Cochet C, Fischer M, et al., European Comission Report No.18 (1997).
  • [6] Chan, W, R et al., LBNL Report #53367 (2003).
  • [7] Clausen, G., Pejtersen, J., Bluyssen, P. M., Copenhaven, Technical University of Denmark and Delft, TNO-Building and Construction Research, 1993.
  • [8] Fanger P. O., Lauridsen, J., Bluyssen, P. et al. Energy Build 12 (1988) 7-19.
  • [9] Health Canada. Exposure guidelines for residential. Indoor Air quality; A report of the Federal-Provincial Advisory Committee on Environmental and Occupational health, Ottawa: health Canada. Publication_Communications, Ottawa, K1A0K9 (1995).
  • [10] Hodgson, A. T., Rudd, A. F., Beal, D. et al., Indoor Air 10 (2000) 178-192.
  • [11] ICMR Bulletin. Indoor air pollution in india – A major environmental and public health concern 31(5) (2001).
  • [12] Kirk, R. S., PNAS 97 24 (2000) 13286-13293.
  • [13] Molhave, L., Indoor Air 1 (1991) 357-376.
  • [14] Molhave L, Bach B, Pedersen O. F., Environ International 12 (1986) 167-165.
  • [15] Pitten, F. A., Bremer, J., Kramer, A., Dtsch med Wschr 125 (2000) 545-550.
  • [16] Rivers, J. C., Pleil, J. D., Wiener, R. W., J Exp Anal Env Epidem 1 (1992) 177-188.
  • [17] Seifert, B., Bundesgesundheitsbl-Gesundheitsforsch-Gesundheitsschutz 42 (1999) 270-278.
  • [18] Wallace, L. A., Pellizzari, E, Leaderer, B. et al., Atmospheric Environment 21(2) (1987) 385-393.
  • [19] Wolkoff, P., Indoor Air 3 (1995) 1-73.
  • [20] Wolkoff P., Proceedings of the 7th International Conference on Indoor Air Quality and Climate. Indoor Air 96(1) (1996) 579-584 Nagaya.
  • [21] Wolkoff, P., Clausen, P. A., Nielsen, P. A., Indoor Air 5 (1995) 196-203.
  • [22] Wolkoff, P., Jensen, P., Kjaer, U., et al., Indoor Air 96(4) (1996) 331-336.
  • [23] World Health Organization (WHO), Air quality guidelines for Europe, 2nd Edition, WHO regional Pubs, European series, No. 91 (2000).
  • [24] World Health Organization (WHO), Based on the WHO-USAID Global Consultation on the Health Impact of Indoor Air Pollution and Household Energy in Developing Countries (Meeting report), Washington, DC, 2002.

Typ dokumentu

Bibliografia

Identyfikatory

Identyfikator YADDA

bwmeta1.element.agro-4f6b5fd6-7d01-480f-aaab-0f7873e43c9a
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.