PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
2009 | 18 | 4 |

Tytuł artykułu

Characterization and biological treatability of edible oil wastewaters

Warianty tytułu

Języki publikacji

EN

Abstrakty

EN
This study investigates the conventional characterization and biological treatability of two different wastewaters that originated from corn oil and sunflower oil refining processes. Our aims for characterization of wastewaters included: total and soluble chemical oxygen demand, total and soluble biological oxygen demand, suspended solid, oil and grease, pH, total kjeldahl nitrogen, ammonia nitrogen, total phosphor, phosphate, color and sulfate analyses. In corn oil wastewaters, total COD is portioned as 80% soluble COD, 20% particular COD, 3.4% total soluble inert COD, 0.5% total particular inert COD, whereas in sunflower oil wastewaters soluble COD, particular COD, total soluble inert COD, total particular inert COD are found as 81.7%, 18.3%, 1.9%, and 5.1%, respectively. In our characterization studies, BOD5/COD ratio were 0.15 and 0.2 for corn oil and sunflower oil wastewaters, respectively. These results indicate that wastewaters are not suitable for biological treatment. But investigation of COD fractions has pointed out that wastewaters contain mostly biodegradable organic substances.

Wydawca

-

Rocznik

Tom

18

Numer

4

Opis fizyczny

p.533-538,fig.,ref.

Twórcy

autor
  • Department of Environmental Engineering, Kocaeli University, 41380, Kocaeli, Turkey
autor
  • Department of Environmental Engineering, Kocaeli University, 41380, Kocaeli, Turkey
autor
  • Department of Environmental Engineering, Kocaeli University, 41380, Kocaeli, Turkey
autor
  • Department of Environmental Engineering, Kocaeli University, 41380, Kocaeli, Turkey

Bibliografia

  • 1. TEZCAN UN U., KOPARAL A.S., OGUTVEREN U.B. Electrocoagulation of vegetable oil refinery wastewater using aluminum electrodes. Journal of Environmental Management 90, 428, 2009.
  • 2. KALE V., KATIKANENI S.S.P., CHERYAN M. Deacidification of ricebran oil by solvent extraction and membrane technology. JAOCS 76 (6), 723, 1999.
  • 3. DECLOUX M., LAMELOISE M.L., BROCARD A., BISSON E., PARMENTIER M., SPIRAERS A. Treatment of acidic wastewater arising from the refining of vegetable oil by crossflow microfiltration at very low transmembrane pressure. Process Biochem. 42 (4), 693, 2007.
  • 4. SRIDHAR S., KALE A., KHAN A.A. Reverse osmosis of edible vegetable oil industry effluent. Journal of Membrane Science 205, 83, 2002.
  • 5. EROGLU V., OZTURK I, SAN H. A., DEMIR I. Comparative evaluation of treatment alternatives for wastewaters from an edible oilrefining industry. Water Sci. Technol. 22 (9), 225, 1990.
  • 6. MKHIZE S.P., ATKINSON B.W., BUX F. Evaluation of a laboratory-scale biological process for the treatment of edible oil effluent. Water SA. 26 (4), 555, 2000.
  • 7. TAY, J.H. Biological treatment of soybean waste. Water Sci. Technol. 22 (9), 141, 1990.
  • 8. ZHONG J., SUN X., WANG C. Treatment of oily wastewater produced from refinery processes using flocculation and ceramic membrane filtration. Sep. Purif. Technol. 32, 93, 2003.
  • 9. ORHON D., ARTAN N. Modelling of Activated Sludge Systems. Technomic Publishing Company. Pennsylvania, U.S.A. 1-580, 1994,
  • 10. HENZE M. Characterization of wastewater for modelling of activated sludge processes. Water Sci. Technol. 25 (6), 1, 1992.
  • 11. ORHON D., ARTAN N., CIMSIT Y. The concept of residual product formation in the modeling of activated sludge. Wat. Sci. Technol. 21 (4-5), 339, 1989.
  • 12. EREMEKTAR G., YILDIZ A., MERIC S. Determination of Inert Chemical Oxygen Demand (COD) Fractions in a Textile Industry Wastewater. Fresenius Env. Bull. 13 (10), 1061, 2004.
  • 13. APHA, AWWA, WEF, Standard methods for the examination of water and wastewater. 20th Edition, American Public Health Association Publication, Washington, D.C. 1995.
  • 14. EKAMA G.A., DOLD P.L., MARAIS G.R. Procedures for determining influent COD fractions and the maximum specific growth rate of heterotrophs in activated sludge systems. Water Sci. Technol. 18, 91, 1986.
  • 15. XU S., HASSELBLAD S. A simple biological method to estimate the readily biodegradable organic matter in wastewater. Water Res. 30 (4), 1023, 1996.
  • 16. MATHIUE S., ETIENNE P. Estimation of wastewater biodegradable COD fractions by combining respirometric experiments in various S0/X0 ratios. Water Res. 34 (4), 1233, 2000.
  • 17. ORHON D., ARTAN N., ATES E. A description of three methods for the determination of the initial inert particulate chemical oxygen demand of wastewater. J. Chem. Tech. Biotechnol. 61, 73, 1994.
  • 18. ORHON D., KARAHAN Ö., SÖZEN S. The effect of residual microbial products on the experimental assessment of the particulate inert COD in wastewaters. Water Res. 33 (14), 3191, 1999.
  • 19. ORHON D., UBAY ÇOKGÖR, E. COD fractionation in wastewater characterization – The state of the art. J. Chem. Tech. Biotechnol. 68, 283, 1997.
  • 20. GERMIRLI B.F., ORHON D., UBAY COKGOR, E., INSEL G., YAPRAKLI B. Modelling of activated sludge for textile wastewaters.Water Sci. Technol. 38 (4-5), 9, 1998.
  • 21. DE LA SOTA, A., LARREA L., NOVAK L., GRAU P., HENZE M. Performance and model calibration of R-D-N process in pilot plant. Water Sci. Technol. 30 (6), 355, 1994.
  • 22. CINER F., SARIOGLU M. Determination of inert chemical oxygen demand (COD) fractions of Cumhuriyet University wastewater. Global NEST Journal 8 (1), 31, 2006.

Typ dokumentu

Bibliografia

Identyfikatory

Identyfikator YADDA

bwmeta1.element.agro-article-f4619b17-6704-4f0b-82d9-583c9ea95fb6
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.