PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
2007 | 22 | 3 |

Tytuł artykułu

The influence of constant magnetic field on ozonolysis of detergent Rokafenol N8

Warianty tytułu

PL
Wplyw stalego pola magnetycznego na proces ozonolizy detergentu Rokafenol N8

Języki publikacji

EN

Abstrakty

EN
The aim of the study was to determine the impact of constant magnetic field (SPM) on the effectiveness of ozonolysis process of detergent Rokafenol N8 (R N8) in water solutions. The experiment was performed in two stages at the laboratory scale. The application of SPM, as an improved factor of ozonolysis process of detergent R N8, gave positive technological results. The higher doses of oxidizing agent, the higher impact of constant magnetic field on the effectiveness of detergent oxidation was observed. When ozone doses was 3.0 g O₃ dm⁻³ h⁻¹, additional application of physical factor let obtain several times lower R N8 concentration in contrary to the results of first experimental stage.
PL
Celem badań było określenie wpływu stałego pola magnetycznego (SPM) na sprawność procesu ozonolizy detergentu Rokafenol N8 (R N8) w roztworach wodnych. Eksperyment przeprowadzono w skali laboratoryjnej, wykorzystując 2 odmienne systemy technologiczne. Skoncentrowano się na określeniu wpływu dawki ozonu, stężenia detergentu w roztworze, czasu zatrzymania w układzie technologicznym oraz znaczenia stałego pola magnetycznego (SPM) na uzyskane efekty degradacji detergentu. Stwierdzono, iż wprowadzenie do układu SPM wpłynęło bezpośrednio na poprawienie efektów, uzyskiwanych w procesie ozonolizy detergentu R N8. Najwyraźniej wpływ czynnika fizycznego zaobserwowano podczas stosowania najwyższej testowanej w eksperymencie dawki utleniacza wynoszacej 3,0 g O₃ dm⁻³ h⁻¹. W tym przypadku zastosowanie SPM pozwoliło na uzyskanie wielokrotnie wyższych efektów końcowych w stosunku do stosowania jedynie procesu ozonolizy.

Słowa kluczowe

Wydawca

-

Rocznik

Tom

22

Numer

3

Opis fizyczny

p.500-511,fig.,ref.

Twórcy

autor
  • University of Warmia and Mazury in Olsztyn, Prawochenskiego 1, 10-957 Olsztyn, Poland
autor
autor

Bibliografia

  • AGUSTINA T.E., ANG H.M., VAREEK V.K. 2005. A review of synergistic effect of photocatalysis and ozonation on wastewater treatment. J. Photochem. & Photob., C: Photochemistry Reviews, 6: 264-273.
  • BARREDO-DAMAS S., IBORRA-CLAR M.I., BES-PIA A., ALCAINA-MIRANDA M.I., MENDOZA-ROCA J.A. 2005. Study of preozonation influence on the physical-chemical treatment of textile wastewater. Desalination, 182: 267-274.
  • BRUNNER P.H., CAPRI S., MARCOMINI A., GIGER W. 1988. Occurrence and behaviour of linear alkylbenzenesulfonates, nonylphenol, nonylphenol monophenol and nonylphenol diethoxylates in sewage and sewage-sludge treatment. Water Res., 22: 1465-1472.
  • FONTANIER V., FARINES V., ALBET J., BAIG S., MOLINIER J. 2006. Study of catalyzed ozonation for advanced treatment of pulp and paper mill effluents. Wat. Res., 40: 303-310.
  • HOIGNÉ J., BADER H. 1994. Characterization of water quality criteria for ozonation processes. P. II: Lifetime of added ozone. Ozone Sci. Engng., 16: 121-134.
  • JAJTE J., GRZEGORCZYK J., ZMYŚLONY M., RAJKOWSKA E. 2002. Effect of 7 mT static magnetic field and iron ions on rat lymphocytes: apoptosis, necrosis and free radical processes. Bioelectrochem., 57: 107-111.
  • KHALIL E.F., WHITMORE T.N., GAMAL-EL-DIN H., EL-BASSEL A., LLOYD D. 1988. The effects of detergents on anaerobic digestion. Appl. Microbiol. Biotechnol. 29: 517-522.
  • KOJO A. MENSAH, FORSTER C.F. 2003. An examination of the effects of detergents on anaerobic digestion., Biores. Technol., 90: 133-138.
  • KOZYREVA YU. N., KOLESNIKOVA E. N., GLUKHAREVA N.A., LEBEDEVA O.E. 2005. Oxidative Degradation of Neonol AF 9-12. Russ. J. Appl. Chem., 78: 2024-2025.
  • KRZEMIENIEWSKI M., DĘBOWSKI M., DOBRZYŃSKA A., ZIELIŃSKI M. 2004. Chemical oxygen demand reduction of various wastewater types using magnetic field – assisted Fenton reaction. Wat. Env. Res., 76: 301-309.
  • KRZEMIENIEWSKI M., DĘBOWSKI M., JANCZUKOWICZ W., PESTA J. 2003. Effect of sludge conditioning by chemical methods with magnetic field application., Pol. J. Environ. Stud., 12: 595-605.
  • LIN S.H., LIN C.M., LEU H.G. 1999. Operating characteristics and kinetic studies of surfactant wastewater treatment by Fenton oxidation. Wat. Res., 33: 1735-1741.
  • MCLAUCHLAN K.A., STEINER U.E. 1991. The spin correlated radical pair as a reaction intermediate. Mol. Phys., 73: 241-263.
  • MODLER R., ISHIKAWA Y. 2001. Surfactants, Report by SRI Consulting,
  • MONTEAGUDO J.M., CARMONA M., DURÁN A. 2005. Photo-Fenton-assisted ozonation of p-Coumaric acid in aqueous solution. Chemosphere, 60: 1103-1110.
  • PAINTER H.A., ZABEL T. 1989. Behaviour of LAS in sewage treatment. Tenside. Surfact. Det. 26: 108-115.
  • PANIZZA M., DELUCCHI M., CERISOLA G. 2005. Electrochemical degradation of anionic surfactants. J. Appl. Electrochem., 35: 357-361.
  • PAPADOPOULOS A., SAVVIDES C., LOIZIDIS M., HARALAMOUS K.J., LOIZIDOU M. 1997: An assessment of the quality and treatment of detergent wastewater. Water Sci. Technol., 36(2-3): 377-381.
  • PARK H.S., HWANG T.M., KANG J.W., CHOI H., OH H.J. 2001. Characterization of raw water for the ozone application measuring ozone consumption rate. Wat. Res., 35: 2607-2614.
  • PASTEWSKI S., MĘDRZYCKA K. 2003. Monitoring Surfactant Concentrations in Surface Waters in Tricity Agglomeration. Pol. J. Env. Stud., 12: 643-646.
  • RENNER R. 1997. European bans on surfactant trigger transatlantic debate. Environ. Sci. Technol., 31: 316A-320A.
  • SANZ J. LOMBRAŃA J. I., DE LUÍS A. 2003. Ultraviolet-H₂O₂ oxidation of surfactants. Environ. Chem. Lett., 1: 32-37.
  • SCHRANK S.G., JOSÉ H.J., MOREIRA R.F.P.M., SCHRÖDER H.F. 2005. Applicability of Fenton and H₂O₂/UV reactions in the treatment of tannery wastewaters. Chemosphere, 60: 644-655.
  • SCOTT M.J., JONES M.N. 2000. The biodegradation of surfactants in the environment. Biochimica et Biophysica Acta, 1508: 235-251.
  • SELCUK H. 2005. Decolorization and detoxification of textile wastewater by ozonation and coagulation processes. Dyes and Pigments, 64: 217-222.
  • SHEMER H., KUNUKCU Y.K., LINDEN G. 2006. Degradation of the pharmaceutical Metronidazole via UV, Fenton and photo-Fenton processes. Chemosphere, 63: 269-276.
  • SHU H.-Y., CHANG M.-C. 2005. Pre-ozonation coupled with UV/H₂O₂ process for the decolorization and mineralization of cotton dyeing effluent and synthesized C.I. Direct Black 22 wastewater. J. Haz. Mat., 121: 27-133.
  • SHURIN J.B., DODSON S.T. 1997. Sublethal toxic ejects of cyanobacteria and nonylphenol on environmental sex determination and development in Daphnia. Environ. Toxicol. Chem., (16): 1269-1276.
  • SONNENSCHEIN C., SOTO A.M. 1998. An update review of environmental estrogen and androgen mimics and antagonists. J. Steroid Biochem. Mol. Biol., 65: 143-150.
  • SZYMANSKI A., WYRWAS B., JESIOLOWSKA A., KAZMIERCZAK S., PRZYBYSZ T., GRODECKA J., ŁUKASZEWSKI Z. 2001. Surfactants in the River Warta: 1990-2000. Pol. J. Env. Stud., 10: 371-377.

Typ dokumentu

Bibliografia

Identyfikatory

Identyfikator YADDA

bwmeta1.element.agro-article-e39fee35-ff9a-4f34-9cbf-0f24b4c817d9
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.