Our study was undertaken to compare the behaviour and properties of two new ketoimine sorbents with a commercial sorbent C-18. The sorbents were used to concentrate the endocrine-disrupting compounds (EDCs) in the water, by the use at solid phase extraction (SPE). EDCs were analyzed by high performance liquid chromatography (HPLC) coupled to UV detection. The residues of bisphenol A, bisphenol A diglycidyl ether, bisphenol F and bisphenol F diglycidyl ether in the water having contact with polycarbonate plastic have been determined. The applicable concentration range was 0.5 to 100 µg/l in water samples. Detection limits were of about 0.20 µg/l for BPA and BPF, and 0.50 µg/l for diglycidyl ether derivatives. The recovery of bisphenol A introduced into water ranged from 93.3% to 97.0%, of BPF from 91.6% to 95.9%, of BADGE from 82.0% to 86.4%, and of BFDGE from 79.7 to 82.5%. The proposed method is simple and sensitive, and thus well suited for analysis of ECDs in the water.

Wydawca

-

Rocznik

Tom

15

Numer

3

Opis fizyczny

p.479-483,fig.,ref.

Twórcy

autor
  • Adam Mickiewicz University, Grunwaldzka 6, 60-780 Poznan, Poland
autor
autor

Bibliografia

  • 1. COLBORN T., DUMANOSKI D., MYERS J. P., Our Stolen Future, Peenguin Books, New York, 1996.
  • 2. MACZKA C., PANG S., POL ICANSKY D., WEDGE R., Evaluating impacts of hormonally active agents in the environment; Environ.Sci.Technol. 34, 136A, 2000.
  • 3. HOCK B., SEIFERT M., 5th European Workshop on Biosensors for Environmental Monitoring of Endocrine Disruptors, Weihstephan, Munich, May 1997.
  • 4. CASTILLO M., BARCELO D., Analysis of industrial effluents to determine endocrine-disrupting chemicals; Trends in Anal. Chem., 16, 574, 1997.
  • 5. KEITH L. H., Environmental Endocrine Disruptors; Pure & Appl. Chem., 70, 2319, 1998.
  • 6. HORIE M., YOSHIDA R., ISHII R., KOBAYASHI S., NAKAZAWA H., Determination of bisphenol A in canned drinks by LC/MS; Bunseki Kagaku 48, 579, 1999.
  • 7. YOSHIDA T., HORIE M., HOSHINO Y., NAKAZAWA H., Determination of bisphenol A in canned vegetables and fruit by high performance liquid chromatography; Food Addit. Contam. 18, 69, 2001.
  • 8. BILES J. E., MCNEAL T. P., BEGLEY T. H., Determination of bisphenol A migrating from epoxy can coatings to infant formula liquid concentrates; J. Agric. Food Chem. 45, 4697, 1997.
  • 9. Opinion of the Scientific Committee on Food on Bisphenol A. SCF/CS/PM/3936 Final (Brussels: European Commission. Health and Consumer Protection Directorate-General) [http://europa.eu.int/comm./food/fs/sc/out128_en.pdf].
  • 10. Del OLMO M., ZAFRA A., JURADO A. B., VILCHEZ J. L., Determination of bisphenol A (BPA) in the presence of phenol by first-derivate fluorescence following microliquidliquid extraction (MLL E); Talanta 50, 1141, 2000.
  • 11. NAASSNER M., MERGLER M., WOLF K., SCHUPHAN I., Determination of the xenoestrogens 4-nonylphenol and bisphenol A by high-performance liquid chromatography and fluorescence detection after derivatisation with dansyl chloride; J. Chromatogr. A, 945, 133, 2002.
  • 12. PULGAR R., OLEA-SERRANO M. F., NOVILLO-FERTRELL A., RIVAS A., PAZOS P., PEDRAZA V., NAVAJAS J. M., OLEA N., Determination of bisphenol A and related aromatic compounds released from bis-GMA-based composites and sealants by high performance liquid chromatography; Environ. Health Perspect. 108, 1, 2000.
  • 13. BROSSA L., POCURULL E., BORRULL F., MARCE R. M., A rapid method for determining phenolic endocrine disrupters in water samples; Chromatographia 56, 573, 2002.
  • 14. INOUE K., YOSHIE Y., KONDO S., YOSHIMURA Y., NAKAZAWA H., Determination of phenolic xenoestrogens in water by liquid chromatography with coulometric-array detection; J. Chromatogr. A 946, 291, 2002.
  • 15. TOYO ’OKA T., OSHIGE Y., Determination of alkylphenols in mineral water contained in PET bottles by liquid chromatography with coulometric detection; Anal. Scie. 16, 1071, 2000.
  • 16. PEDERSEN S. N.,LINDHOLST C., Quantification of the xenoestrogens 4-tert.-octylphenol and bisphenol A in water and in fish tissue based on microwave assisted extraction, solid-phase extraction and liquid chromatography-mass spectrometry; J. Chromatogr. A 864, 17, 1999.
  • 17. RODRIGUEZ-MOZAZ S., LOPEZ DE ALDA M., BARCELO D., Monitoring of estrogens, pesticides and bisphenol A in natural waters and drinking water treatment plants by solid-phase extraction-liquid chromatography-mass spectrometry; J. Chromatogr. A 1045, 85, 2004.
  • 18. JEANNOT R., SABIK H., SAUVARD E., DAGNAC T., DOHRENDORF K., Determination of endocrine-disrupting compounds in environmental samples using gas and liquid chromatography with mass spectrometry; J. Chromatogr. A 974, 143, 2002.
  • 19. Del OLMO M., GONZALEZ-CASADO A., NAVAS N. A., VILCHEZ J. L., Determination of bisphenol A (BPA) in water by gas chromatography-mass spectrometry; Anal. Chim. Acta 346, 87, 1997.
  • 20. BRAUN P., MOEDER M., SCHRADER ST., POPP P., KUSCHK P., ENGEWALD W., Trace analysis of technical nonylphenol, bisphenol A and 17α-ethinylestradiol in wastewater using solid-phase microextraction and gas chromatography-mass spectrometry; J. Chromatogr. A 988, 41, 2003.
  • 21. LIU R., ZHOU J. L., WILDING A., Simultaneous determination of endocrine disrupting phenolic compounds and steroids in water by solid-phase extraction-gas chromatography-mass spectrometry; J. Chromatogr. A 1022, 179,2004.
  • 22. KUO H. W., DING W. H., Trace determination of bisphenol A and phyestrogens in milk powders by gas chromatography-mass spectrometry; J. Chromatogr. A 1027, 67, 2004.
  • 23. TAKEDA S., IIDA S., CHAYAMA K., TSUJI H., FUKUSHI K., WAKIDA S., Separation of bisphenol A and three alkylphenols by micellar electrokinetic chromatography; J.Chromatogr. A 895, 213, 2000.
  • 24. TAKEDA S., OMURA A., CHAYAMA K., TSUJI H., FUKUSHI K., YAMANE M., WAKIDA S., TSUBOTA S., TERABE S., Separation and on-line concentration of bisphenol A and alkylphenols by micellar elektrokinetic chromatography with anionic surfactant; J. Chromatogr. A 1014, 103, 2003.
  • 25. WASIAK W., RYKOWSKA I., VOELKEL A., Ketoimino groups as silica surface modifiers; J. Chromatogr. A 969, 133, 2002.

Typ dokumentu

Bibliografia

Identyfikatory

Identyfikator YADDA

bwmeta1.element.agro-article-8923bd20-4240-48e2-ac81-40c8c27255a7
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.