Impact of a sewage treatment plant on health of local residents: gastrointestinal system symptoms

Warianty tytułu

Języki publikacji

EN

Abstrakty

EN
The aim of this study was to evaluate the impact of a sewage treatment plant on the occurrence of gastrointestinal symptoms among the local residents. A survey was conducted on two populations: one from the vicinity of the sewage treatment plant (the exposed group: 586 people), and the other from outside the impact area of the plant (the control group: 502 people). The research area was divided into distance zones from the plant (A, B, C). The questionnaire included questions about the occurrence of gastrointestinal disorders. Compared with the control group, the local residents reported more often: nausea, vomiting, and frequent diarrhea. Occurrences of gastrointestinal disorders were associated with air pollution by pathogenic staphylococci (OR~7) and odours (OR = 7.34; Cl 3.43-15.72) emitted by the plant, and also living in zone A vs. zone C (OR = 3.47; CI 1.00-12.07), use of a gas cooker in houses (OR = 2.21; CI 1.03-4.70), and the age of the respondents (0.98; CI 0.96-1.00). The study showed that as distance from the plant increased, the incidence of reported gastrointestinal disorders declined. Living in the vicinity of a sewage treatment plant favours the occurrence of gastrointestinal symptoms among the local residents.

Słowa kluczowe

Wydawca

-

Rocznik

Tom

26

Numer

1

Opis fizyczny

p.127-136,fig.,ref.

Twórcy

autor
  • Department of Hygiene, Medical University of Wroclaw, J. Mikulicza-Radeckiego 7, 50-368 Wroclaw, Poland
autor
  • Faculty of Environmental Engineering, Wroclaw University of Technology, Wybrzeze Wyspianskiego St. 27, 50-370 Wroclaw, Poland
autor
  • Faculty of Environmental Engineering, Wroclaw University of Technology, Wybrzeze Wyspianskiego St. 27, 50-370 Wroclaw, Poland
autor
  • Faculty of Environmental Engineering, Wroclaw University of Technology, Wybrzeże Wyspianskiego St. 27, 50-370 Wroclaw, Poland
autor
  • Faculty of Environmental Engineering, Wroclaw University of Technology, Wybrzeze Wyspianskiego St. 27, 50-370 Wroclaw, Poland
autor
  • Department of Hygiene, Medical University of Wroclaw, J. Mikulicza-Radeckiego 7, 50-368 Wroclaw, Poland
  • Institute of Occupational Medicine and Environmental Health, Koscielna 13, 41-200 Sosnowiec, Poland

Bibliografia

  • 1. AL-BATANONY M.A., EL-SHAFIE M.K. Work-Related Health Effects among Wastewater Treatment Plants Workers. Int. J. Occup. Environ. Med., 2 (4), 237, 2011.
  • 2. ABD EL-WAHAB E.W., EASSA S.M., LOTFI S.E., EL MASRY S.A., SHATAT H.Z., KOTKAT A.M. Adverse health problems among municipality workers in alexandria (egypt). Int. J. Prev. Med. 5 (5), 545, 2014.
  • 3. ALBRECHT A., FISCHER G., BRUNNEMANN-STUBBE G., JÄCKEL U., KÄMPFER P. Recommendations for study design and sampling strategies for airborne microorganisms, MVOC and odours in the surrounding of composting facilities. Int. J. Hyg. Environ. Health, 211 (1-2), 121, 2008.
  • 4. FISCHER G., ALBRECHT A., JÄCKEL U., KÄMPFER P. Analysis of airborne microorganisms, MVOC and odour in the surrounding of composting facilities and implications for future investigations. Int. J. Hyg. Environ. Health, 211 (1-2), 132, 2008.
  • 5. RYLANDER R. Health effects among workers in sewage treatment plants. Occup. Environ. Med., 56 (5), 354, 1999.
  • 6. AATAMILA M., VERKASALO P.K., KORHONEN M.J., SUOMINEN A.L., HIRVONEN M.R., VILUKSELA M.K., NEVALAINEN A. Odour annoyance and physical symptoms among residents living near waste treatment centres. Environ. Res., 111 (1), 164, 2011.
  • 7. OIAMO T.H., LUGINAAH I.N., BAXTER J. Cumulative effects of noise and odour annoyances on environmental and health related quality of life. Soc. Sci. Med. 146, 191, 2015.
  • 8. STILIANAKIS N.I., BOEDEKER R.H., EIKMANN T.F. Effects of bioaerosol polluted outdoor air on airways of residents: a cross sectional study. Occup. Environ. Med., 60 (5), 336, 2003.
  • 9. CENTRAL STATISTICAL OFFICE OF POLAND. Environmental protection 2015. Regional and Environmental Surveys Department. Report Published date: 2015 http://stat.gov.pl/download/gfx/portalinformacyjny/en/defaultaktualnosci/3303/1/7/1/environment_2015.pdf (accessed 24 January 2016).
  • 10. ZŁOTKOWSKA R., JAŹWIEC-KANYION B., KRUŻEL-MENDREK J., ZEJDA J. Air pollution and respiratory health in children, results of a PHARE-CESAR study in Poland. Proceedings of the Latvian Academy of Sciences, 52 (Supl.), 172, 1998.
  • 11. VDI 3940 PART 3, Measurement of odour in ambient air by field inspections – Determination of odour intensity and hedonic odour tone, Verein Deutscher Ingenieure, Berlin, Beuth Verlag, Germany, 2010.
  • 12. POLISH STANDARDS PN-89/Z-04111/02. Air purity protection. Microbiological testings. Determination number of bacteria in atmospheric air (imision) with sampling by aspiration and sedimentation method (Ochrona czystości powietrza. Badania mikrobiologiczne. Oznaczanie liczby bakterii w powietrzu atmosferycznym (imisja) przy pobieraniu próbek metodą aspiracyjną i sedymentacyjną), Polski Komitet Normalizacji, Miar i Jakości, Warsaw, Poland, 1989 [In Polish].
  • 13. POLISH STANDARDS PN-89/Z-04111/03. Air purity protection. Microbiological testings. Determination number of the fungi in the atmospheric air (imision) with sampling by aspiration and sedimentation method (Ochrona czystości powietrza. Badania mikrobiologiczne. Oznaczanie liczby grzybów mikroskopowych w powietrzu atmosferycznym (imisja) przy pobieraniu próbek metodą aspiracyjną i sedymentacyjną), Polski Komitet Normalizacji, Miar i Jakości, Warsaw, Poland, 1989 [In Polish].
  • 14. GANGULY S., MUKHOPADHAYAY S.K., BISWAS S. Potential threat to human health from foodborne illness having serious implications on public health- a Review. IJCBS, 1, 65, 2012.
  • 15. KORZENIEWSKA E., FILIPKOWSKA Z., GOTKOWSKA-PŁACHTA A., JANCZUKOWICZ W., DIXON B., CZUŁOWSKA M. Determination of emitted airborne microorganisms from a BIO-PAK wastewater treatment plant. Water Res. 43 (11), 2841, 2009.
  • 16. VAN HOOSTE W., CHARLIER A.M., ROTSAERT P., BULTERYS S, MOENS G., VAN SPRUNDEL M., De SCHRYVER A. Work-related Helicobacter pylori infection among sewage workers in municipal wastewater treatment plants in Belgium. Occup. Environ Med., 67 (2), 91, 2010.
  • 17. SMIT L.A., SPAAN S., HEEDERIK D. Endotoxin exposure and symptoms in wastewater treatment workers. Am. J. Ind. Med., 48 (1), 30, 2005.
  • 18. BYSTROŃ J., LIS E., BANIA J., MOLENDA J. 2008 Occurrence of methicillin-resistant genes in Staphylococcus aureus strains. Acta Sci. Pol. Med. Vet., 7, 3, 2008.
  • 19. ROSENBERG GOLDSTEIN R.E., MICALLEF S.A., GIBBS S.G., HE X., GEORGE A., SAPKOTA A., JOSEPH S.W., SAPKOTA A.R. Occupational exposure to Staphylococcus aureus and Enterococcus spp. among spray irrigation workers using reclaimed water. Int. J. Environ. Res. Public Health., 11 (4), 4340, 2014.
  • 20. HERR C.E.W., ZUR NIEDEN A., BOEDEKER R.H., GIELER U., EIKMANN T.F. Ranking and frequency of somatic symptoms in residents near composting sites with odor annoyance. Int. J. Hyg. Environ. Health., 206 (1), 61, 2003.
  • 21. UHBRAND K., SCHULTZ A.CH., MADSEN A.M. Exposure to Airborne Noroviruses and Other Bioaerosol Components at a Wastewater Treatment Plant in Denmark. Food Environ. Virol., 3 (3), 130, 2011.
  • 22. LEONDA I., MARSH R., MKILAHA I., GRIFFITHS A. Carbon Monoxide Exposure during Cooking in Households: A Case of Dar es Salaam City, Tanzania. JESE-A, 2, 31, 2013.
  • 23. OZMERT E.N., KILIC M., YURDAKÖK K. Environmental tobacco smoke: is it a risk factor for diarrhea in 6-18 months old infants? Cent. Eur. J. Public Health. 16 (2), 85, 2008.
  • 24. SIMON A.K., HOLLANDER G.A, MCMICHAEL A. Evolution of the immune system in humans from infancy to old age. Proc. Biol. Sci. 282 (1821), 20143085, 2015.
  • 25. SLY L., BRUNE-DRISSE M.N. Children’s Vulnerability to Their Environment. J. Environ. Immunol. Toxicol. 1 (2), 58, 2014.
  • 26. SIRONI M., CLERICI M. The hygiene hypothesis: an evolutionary perspective. Microbes Infect., 12, 421, 2010. 27. BODUR S. 2014 Epidemiology of indoor air pollution. J Chest Dis. Crit. Care Med., 1, 41, 2014.

Typ dokumentu

Bibliografia

Identyfikatory

Identyfikator YADDA

bwmeta1.element.agro-3a2d8375-5709-46c8-927c-139e3b00de46
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.