PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
2014 | 17 | 3 |

Tytuł artykułu

Effect of 24 hour application of three hemostatic dressing to porcine thigh muscles

Treść / Zawartość

Warianty tytułu

Języki publikacji

EN

Abstrakty

EN
The effectiveness of three types of hemostatic dressings, QuikClot Gauze, ChitoGauze PRO and Celox Gauze, was evaluated in nine pigs. The results indicated a strong influence of all examined dressings on porcine femoral muscle tissue evaluated 24 hours after direct contact. A histopathological analysis revealed pathological changes in muscle tissue specimens collected from all the animals.

Słowa kluczowe

Wydawca

-

Rocznik

Tom

17

Numer

3

Opis fizyczny

p.519-521,fig.,ref.

Twórcy

autor
  • Department of Surgery and Radiology, University of Warmia and Mazury in Olsztyn, Oczapowskiego 14, 10-719 Olsztyn, Poland
  • Security Fundamentals Unit, Police Academy, Pilsudskiego 111, 12-100 Szczytno, Poland
  • Department of Internal Diseases, University of Warmia and Mazury in Olsztyn, Oczapowskiego 14, 10-719 Olsztyn, Poland
  • Department of Pathological Anatomy, University of Warmia and Mazury in Olsztyn, Oczapowskiego 13 bl. D, 10-719 Olsztyn, Poland
autor
  • Department of Surgery and Radiology, University of Warmia and Mazury in Olsztyn, Oczapowskiego 14, 10-719 Olsztyn, Poland
  • Department of Surgery and Radiology, University of Warmia and Mazury in Olsztyn, Oczapowskiego 14, 10-719 Olsztyn, Poland
  • Department of Surgery and Radiology, University of Warmia and Mazury in Olsztyn, Oczapowskiego 14, 10-719 Olsztyn, Poland
autor
  • Department of Surgery and Radiology, University of Warmia and Mazury in Olsztyn, Oczapowskiego 14, 10-719 Olsztyn, Poland

Bibliografia

  • Arnaud F, Teranishi K, Tomori T, Carr W, McCarron R (2009) Comparison of 10 hemostatic dressings in a groin puncture model in swine. J Vasc Surg 50: 632-639.
  • Arnaud F, Tomori T, Carr W, McKeague A, Teranishi K, Prusaczyk K, McCarron R (2008) Exothermic reaction in zeolite hemostatic dressings: QuikClot ACS and ACS +. Ann Biomed Eng 36: 1708-1713.
  • Devlin JJ, Kircher S, Kozen BG, Littlejohn LF, Johnson AS (2011) Comparison of ChitoFlexⓇ, CeloxTM, and Quik- ClotⓇ in control of hemorrhage. J Emerg Med 41: 237-245.
  • King DR (2011) Thirty consecutive uses of a hemostatic bandage at a US Army Combat Support Hospital and forward Surgical Team in Operation Iraqi Freedom. J Trauma 71: 1775-1778.
  • McManus J, Hurtado T, Pusateri A, Knoop KJ (2007) A case series describing thermal injury resulting from zeolite use for hemorrhage control in combat operations. Prehosp Emerg Care 11: 67-71.
  • Rhee P, Brown C, Martin M, Salim A, Plurad D, Green D, Chambers L, Demetriades D, Velmahos G, Alam H (2008) QuikClot use in trauma for hemorrhage control: case series of 103 documented uses. J Trauma 64: 1093-1099.

Typ dokumentu

Bibliografia

Identyfikatory

Identyfikator YADDA

bwmeta1.element.agro-04961389-4b91-4a25-a01b-412b7274b59c
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.