Ograniczanie wyników

Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 30

Liczba wyników na stronie
Pierwsza strona wyników Pięć stron wyników wstecz Poprzednia strona wyników Strona / 2 Następna strona wyników Pięć stron wyników wprzód Ostatnia strona wyników

Wyniki wyszukiwania

Wyszukiwano:
w słowach kluczowych:  household sewage
help Sortuj według:

help Ogranicz wyniki do:
Pierwsza strona wyników Pięć stron wyników wstecz Poprzednia strona wyników Strona / 2 Następna strona wyników Pięć stron wyników wprzód Ostatnia strona wyników
Seven small wastewater treatment plants were chosen for evaluation. These WWTPs work on the principle of anaerobic pre-treatment and aerobic post-treatment and were made with the cooperation of Slovak Technical University with ASIO-SK s.r.o. Bytča and ASIO s.r.o. Brno. Wastewater treatment plants are made for 5-600 PE. When operated at suitable conditions, the results match the directive water discharge from small wastewater treatment plants in the Slovak Republic.
Artificial aeration was added to an integrated vertical-flow constructed wetland (called aerated IVCW hereafter) for improving water purification performance. The results showed that both oxygen levels and aerobic zones were increased in the wetland substrates. The electric potential (Eh) profiling demonstrated that artificial aeration maintained the pattern of sequential oxic-anoxic-oxic redox zones within the aerated IVCW chambers in winter, while only two oxic-anoxic zones were present inside the non-aerated IVCW in the cold seasons. The nitrification/denitrification processes and organic matter decomposition were enhanced by artificial aeration since the removal efficiency of NH₄⁺-N and BOD₅ were significantly improved in all seasons, particularly in winter. It seemed that artificial aeration could compensate for the absence of plant-mediated oxygen supply, though the low temperatures and plant dieback still affected the removal efficiency of COD and TN in the winter. Eight hours of artificial aeration per day was sufficient to eliminate the significant accumulation of NO₃⁻-N previously observed in the effluent from continuously aerated subsurface-flow constructed wetlands. These results suggest that the aerated IVCW could treat domestic sewage more efficiently, especially in winter.
In the paper we present the evaluation of the effectiveness of the removal of biogenic compounds and indicator bacteria from domestic sewage in a vertical flow filter with a variety of fillings. The research was carried out on expanded clay, zeolite, calcined siliceous limestone, and crushed PET flakes. Based on the study of raw and treated wastewater, the effectiveness of removal of ammonium nitrogen, orthophosphates, Escherichia coli, and coliform bacteria was determined according to the selectivity, porosity and grain size of the fill. In the case of removing biogenic compounds, the most effective fillers were found to be of natural porous selective materials, such as zeolite and calcined siliceous limestone. They produced a very high removal rate of ammonium and orthophosphate, amounting to 75.34%, and over 79%, respectively. It has been demonstrated that the filter that was filled with natural porous material of fine particle size (the zeolite) was the most suitable for the removal of indicator bacteria. A very high degree of the Escherichia coli (99.98%) and coliform bacteria (99.94%) reduction was obtained.
Water is a resource of increasing scarcity due to continual expansion of production. Many authors have focused on wastewater recycling for industry and municipal wastewater plants, but wastewater recycling at the community level still lacks a full discussion. This paper focuses on the issue involving only household wastewater recycling which is separated into graywater and blackwater by households. We propose a theoretical framework for analyzing the recycling of household graywater through a simple process that is installed in communities, as well as the re-use of reclaimed water for a variety of applications either in or outside the community. There are at present no statutory regulations to govern the re-use of reclaimed water. Hence, piping and ducting systems for blackwater and graywater in households are not distinguished and a public ducting system for graywater is still not available in the market. In order to shed light on the dynamics of the household wastewater recycling system, we develop an implementation plan involving governmental policy, a community’s construction of treatment plants, a household’s commitment to recycling, control and checking up, and the education system in order to arouse the public to participate in this system.
The paper presents results of two year field and laboratory investigations of a denitrifying system below leach lines. More than two days retention time was provided by siphoning of the denitrifying trough located 35 and 60 cm under the leach lines. Due to clogging and capillary suction in medium sand the seepage flow through the denitrifying troughs was limited to less than 10 % of the sewage inflow. Average efficiency of the total nitrogen removal was equal to 55 % after 3-4 days of travel time within the soil. To force wastewater to pass through the anaerobic bed within the trough two lateral vertical impermeable membranes are recommended.
The possibility of an electromagnetic field (EMF) influencing the intensification of phosphorus (P) and organic compound (COD) removal from domestic wastes was investigated. The impact of an EMF as the only factor or as an intensifying element in steel packing systems that limits pollutant concentrations in the treated wastes was analysed. The research was conducted in three stages in a static system at the laboratory scale. A significant dependence between the kind of system used, time of detention, flux intensity electromagnetic field and the effectiveness of the pollutants limitation were observed. Most efficient was the system that combined simultaneously steel filling and under electromagnetic flux intensity O = 100.0 µWb and O= 135.0 µWb. In the case of 48 hours the reaction time let to remove from the system the whole phosphorus amount as P-PO4 for treated sewage. These technological variants seem to be the most effective as for Ptot and COD.
The studies conducted in the three-stage waste-water treatment plant for agricultural and domestic sewage in Łężany showed that the greatest reduction of indicator microorganisms, between 70% and 100%, occured in biological ponds. Biofilters (rotating biological disks and multicage rotating contactor) reduced the occurence of the studied microorganisms by 40—70%, mechanical purification by 40—50%. The purified sewage flowing to Legińskie Lake possessed the features of unpolluted or only slightly polluted water.
Celem badań było określenie, w jakim zakresie występujące w okresie wiosennym roztopy śniegu wpływają na podwyższenie dopływu wód przypadkowych do oczyszczalni ścieków w systemach kanalizacji rozdzielczej. Badania prowadzono od 1stycznia 2010 do 30 marca 2010 roku w czterech wybranych systemach kanalizacyjnych zlokalizowanych na terenie województwa małopolskiego. W ramach badań prowadzono pomiary godzinowej temperatury powietrza atmosferycznego oraz dobowe pomiary przepływających ścieków.    Intensywne roztopy śniegu w roku 2010 rozpoczęły się 19 lutego, a zakończyły 4 marca. Średni udział wód przypadkowych w dopływie ścieków do poszczególnych oczyszczalni w okresie roztopów wynosił od 36,6 do 58,1%. Największe dopływy wód przypadkowych wystąpiły w dniu 1 marca (średnia dobowa temperatura powietrza 6,6°C), a ich udziały w stosunku do przepływu średniego dobowego przy pogodzie bezdeszczowej wyniosły odpowiednio: 56,8% w kanalizacji A, 74,3% w kanalizacji B, 54,7% w kanalizacji C i 76,5% w kanalizacji D. Przedstawione liczby wskazują, że we wszystkich analizowanych systemach kanalizacyjnych ponad 50% przepływu dobowego stanowiły wody przypadkowe wywołane roztopami śniegu. W okresie największych roztopów śniegu, tj. od 19 lutego do 3 marca 2010 roku, do badanych systemów kanalizacyjnych dopłynęły wody przypadkowe w ilości: 3641 m3 w kanalizacji A, 6926 m3 w kanalizacji B, 1854 m3 w kanalizacji C i 5846 m3 w kanalizacji D. Za przyczynę dopływu wód roztopowych do kanalizacji uznano otwory we włazach studzienek rewizyjnych oraz nielegalne podłączenia rynien dachowych lub wpustów podwórzowych do kolektorów sanitarnych.
W pracy poddano analizie zagospodarowanie gruntów wybranych miejscowości gminy Jelcz-Laskowice po kątem przydatności rolniczego wykorzystania ścieków do nawodnień. Na podstawie dostępnej literatury przedstawiono możliwości zagospodarowania ścieków pochodzących z trzech położonych obok siebie sołectw: Biskupice Oławskie, Minkowice Oławskie i Wójcice. Wskazano korzyści wynikające z proponowanego rozwiązania, a także przeanalizowano istniejącą infrastrukturę techniczną oraz możliwości jej rozbudowy.
W pracy przedstawiono wyniki badań dotyczące skuteczności pracy obiektów roślinno-glebowych w latach 2002-2005. Oczyszczalnie roślinno-glebowe stanowią korzystne rozwiązanie oczyszczania ścieków na terenach bez centralnej kanalizacji. Charakteryzują się niskimi kosztami utrzymania oraz wysoką skutecznością pracy, która wynosi dla BZT₅ powyżej 98%, natomiast dla azotu ogólnego 87%. Wybrane obiekty roślinno-glebowe w trakcie trwania badań pracowały w warunkach niekorzystnych, związanych z nierównomiernym dopływem ścieków surowych, przeciążeniem złoża ładunkiem zanieczyszczeń oraz niskimi temperaturami w okresie zimowym. Pomimo tak niekorzystnych warunków nie zaobserwowano spadku skuteczności oczyszczania ścieków na tych obiektach.
The removal of the nutrients: different forms of nitrogen, phosphorus and carbon, by two constructed wetland systems with reed (Phragmites australis) was investigated between the spring 2000 and the summer 2001. Two systems: reed pond with surface flow and sand reed bed with subsurface flow, have been compared Both the systems show high performance wastewater purification during whole vegetation season. Higher removal of nitrogen forms and organic carbon was observed in the reed bed with subsurface flows. This can be caused by higher biomass and density of plants than that, in reed pond with surface flow. The content of phosphorus in both systems significantly increased.
Pierwsza strona wyników Pięć stron wyników wstecz Poprzednia strona wyników Strona / 2 Następna strona wyników Pięć stron wyników wprzód Ostatnia strona wyników
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.