Ograniczanie wyników

Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 17

Liczba wyników na stronie
Pierwsza strona wyników Pięć stron wyników wstecz Poprzednia strona wyników Strona / 1 Następna strona wyników Pięć stron wyników wprzód Ostatnia strona wyników

Wyniki wyszukiwania

Wyszukiwano:
w słowach kluczowych:  chemical oxygen demand
help Sortuj według:

help Ogranicz wyniki do:
Pierwsza strona wyników Pięć stron wyników wstecz Poprzednia strona wyników Strona / 1 Następna strona wyników Pięć stron wyników wprzód Ostatnia strona wyników
The diversity of aquatic macrophytes plays an important role in wastewater purification. To optimize poly-culture vegetation structure, Typha-Phragmites-Scirpus (with T. angustata, P. communis, S. validus as major species) vegetation, Typha-main (with T. angustata as major species) vegetation and Typha-monoculture vegetation as three design treatments were planted in pilot-scale gravel-based subsurface wetlands to treat artificial sewage. The Typha vegetation depicted had high COD, TN and TP removal loads in wetlands when low pollution load was treated, Typha-Phragmites-Scirpus vegetation had COD, TP and TN removal loads of 0.517 g m⁻² d⁻¹, 0.277 g P m⁻² d⁻¹ and 0.023 g N m⁻² d⁻¹ in autumn. A Partial Correlations Analysis showed that COD removal loads significantly and positively correlated with plant species and stem density in either pilot scale or medium-sized (430 m² in area) constructed wetland. The N, P amounts in the above-ground tissue are only 3.5~11.1 g N m⁻² yr⁻¹ and 1.3~13.5 g P m⁻² yr⁻¹ in medium-sized and pilot scale wetlands, because both biomass and N, P contents of wetland vegetation harvested in late autumn were low. Thus, it is important for constructed wetlands to optimize poly-culture vegetation structure to improve treatment efficiency. Generally, the poly-culture wetlands vegetation of T. angustata, P. communis, S. validus, Z. latifolia, Acorus calamus with stem densities of 23 stem m⁻², 194 stem m⁻², 112 stem m⁻², 26 stem m⁻², 42 stem m⁻² could gain excellent removal efficiency.
This study investigates the conventional characterization and biological treatability of two different wastewaters that originated from corn oil and sunflower oil refining processes. Our aims for characterization of wastewaters included: total and soluble chemical oxygen demand, total and soluble biological oxygen demand, suspended solid, oil and grease, pH, total kjeldahl nitrogen, ammonia nitrogen, total phosphor, phosphate, color and sulfate analyses. In corn oil wastewaters, total COD is portioned as 80% soluble COD, 20% particular COD, 3.4% total soluble inert COD, 0.5% total particular inert COD, whereas in sunflower oil wastewaters soluble COD, particular COD, total soluble inert COD, total particular inert COD are found as 81.7%, 18.3%, 1.9%, and 5.1%, respectively. In our characterization studies, BOD5/COD ratio were 0.15 and 0.2 for corn oil and sunflower oil wastewaters, respectively. These results indicate that wastewaters are not suitable for biological treatment. But investigation of COD fractions has pointed out that wastewaters contain mostly biodegradable organic substances.
6
84%
Wastewater treatment is becoming ever more critical due to diminishing water resources, increasing wastewater disposal costs, and stricter discharge regulations that have lowered permissible contaminant levels in waste streams. The ultimate goal of wastewater management is the protection of the environment in a manner commensurate with public health and socio-economic concerns. The aim of our study is to use natural occurring plant (Pistia stratiotes) to reduce the chemical oxygen demand and color from the industrial waste water. It was found that 120 mg/l of Chemical oxygen demand and 85 mg/l of color reduction was observed with Pistia stratiotes.
This study aimed at the simultaneous treatment of wastewater obtained from swine and generation of bioenergy in form of electricity from the energy stored in the organic component of the wastewater. The Open circuit voltage, current, power density and microbiological and physicochemical parameters were monitored. An initial Open circuit voltage of 516mV, Current of 0.29mA, and Power density of 32.74mW/m2 were recorded, which increased to give maximum Open Circuit Voltages of 836mV, Current of 0.49mA, and Power density of 88.45mW/m2. The results revealed that The Chemical Oxygen Demand (COD), Biochemical Oxygen Demand (BOD), Organic carbon, Total Soluble solids (TSS), Ammonia, Ammonium and Ammonium-Nitrogen all showed percentage decrease of 85.92%, 51.74%, 78.16%, 98.87%, 55.87%, 55.79% and 55.90% respectively while parameters such as Total Dissolved Solids (TDS), Nitrate, Nitrate-Nitrogen, Phosphates, Phosphorus and Orthophosphates however increased after treatment to give a percentage increase of -273.60%, -131.65%, -134.85%, -168.77%, -159.26%, and -157.03% respectively. Bacteria isolates identified at the biofilms on the anode were Corynebacterium specie, Bacillus specie, Staphylococcus aureus, Escherichia coli, Pseudomonas aeruginosa and Streptococcus faecalis. The results from this study further exacerbate the Bioelectricity production as well as wastewater treatment potentials of the Microbial Fuel Cell technology.
A pot experiment was carried out under controlled conditions to evaluate the combined effect of chemical oxygen demand and heavy metals in synthetic irrigation water on the accumulation of heavy metals in perennial rye grass (Lolium perenne) grown during 30 days on two soils: an acidic sandy soil (pH = 4.0), and the same soil amended with 5% clay (pH = 6.7). The dry matter yield of rye grass decreased and heavy metal concentrations in plant tissue increased with heavy metal concentration in the irrigation water. A higher COD concentration in the irrigation water also resulted in an overall decrease of dry matter yield and higher metal contents. The addition of 5% clay to the acidic soil reduced these effects. However, the clay content of the soil was by far the most important factor in controlling plant growth and metal uptake.
The removal of chemical oxygen demand (COD), lignin and phenol from paper mill effluents was experimentally investigated using an electrode cell consisting of graphite electrode and powder-activated carbon (as working electrode). The effects of electrolyses time, voltage, initial pH, activated carbon (AC), NaCl amount and airflow were selected as parameters. The experimental results show that removal effi­ciency significantly depends on the applied cell voltage, airflow, time, salt amount and pH. For electrolyses under the conditions of 25.0V cell voltage, 5.0 min, in presence of air 2.0 minL-1, NaCl 5.0gL-1 at low pH and AC 20gL-1, it can be said that the removal of COD, lignin and phenol from the paper mill effluent were almost higher than 90%. The present study proves the effectiveness of electrochemical treatment for the highly concentrated organic pollutants present in paper mill effluents.
Miedwie Lake is the biggest post-glacial lake of the West-Pomeranian Voievodship. At the same time it is the fifth of the largest lakes in Poland. As regards the geographical situation, Miedwie Lake is situated centrally between three big agglomerations i.e. Szczecin, Stargard Szczecinski and Pyrzyce (Fig. 1). The lake lies on the territory of three municipalities: Pyrzyce and Warnice in the District of Pyrzyce as well as Stargard Szczecinski in the District of Stargard (Rozmiarek 1983, Szyper 1990). At the moment, the reservoir is characterised with the regular, prolonged shape resembling an ellipse. Banks are shallow, regular and sometime very wet. The lake has the belt of the nearshore reaching locally tens metres far from the lake bank, what is the reason, together with the fact that the wind blows always here, that it is convenient for practising the various kinds of water sports. The lake area amounts to 3 527 ha; maximal depth – 43.8 m; average depth – 19.3 m; water capacity – 681.7 mln m3; shore-line length – 38.8 km; water level datum 14.1 m above sea level; maximal width 3.16 km; maximal length 16.2 km. The lake’s bottom is the lowest situated area on the territory of Poland.
Badania prowadzono na holomiktycznym Jeziorze Wulpińskim położonym w okolicach Olsztyna. Próbki pobierano w okresie cyrkulacji jesiennej 2007 r. i wiosennej 2008 r. nad głęboczkami obu jego zatok i porównano w danymi wcześniejszymi. Zbiornik składa się z dwóch części: eumiktycznej tomaszkowskiej (459 ha, 22 m) i bradymiktycznej barwińskiej (246 ha, 54,6 m) oddzielonych od siebie przesmykiem o długości ok. 60 m i głębokości 3,8 m. Podzlewnie obu zatok różnią się wielkością i sposobem użytkowania. Część tomaszkowska jest bardziej narażona na presję turystyczną i w 62,7% użytkowana rolniczo, natomiast w podzlewni barwińskiej pola i łąki stanowią 46,3%. Znalazło to odzwierciedlenie w uzyskanych wynikach badań: akwen tomaszkowski charakteryzowała niższa widzialność krążka Secchiego (1,5–1,75 m), wyższe stężenie chlorofilu a (23,25– –26,19 mg ∙ m–3) i feofityny (60,11–64,77 mg ∙ m–3), większa ilość materii organicznej allochtonicznej i wyraźna tendencja wzrostowa tego parametru w naddennej warstwie wód. W puli azotu ogólnego dominowała forma organiczna (85–99%).
W pracy przedstawiono analizę wpływu zanieczyszczeń opisanych wartościami BZT5, ChZT i zawiesiny ogólnej w ściekach bytowych oraz pochodzących z masarni i ubojni trzody chlewnej na ich stężenie w mieszaninie ścieków dopływającej do oczyszczalni Bioblok PS-50 w Gruszowie. Średnie stężenia badanych wskaźników w mieszaninie ścieków obliczono jako średnią ważoną. Stwierdzono, że gdy te stężenia są zbyt wysokie, skutkuje to zakłóceniami w pracy oczyszczalni. Średnie ważone poszczególnych wskaźników wynosiły: BZT5 – 592,1 mg O2 ∙ dm–3, ChZT – 974,8 mg O2 ∙ dm–3, zawiesiny ogólnej – 570,7 mg ∙ dm–3. Aby zmniejszyć stężenie zanieczyszczeń w mieszaninie surowych ścieków dopływających do oczyszczalni należy zwiększyć udział procentowy ścieków bytowych z 82% do 96%. Jest to możliwe poprzez rozbudowę sieci kanalizacyjnej i podłączenie do niej kolejnych gospodarstw domowych oraz dodatkową modernizację istniejących lub nowo zainstalowanych systemów podczyszczania ścieków przemysłowych w miejscu ich powstania.
Praca przedstawia wyniki badań wskaźników jakości wody potoku Osielczyk, na którym planowana jest budowa małego zbiornika wodnego w ramach programu małej retencji województwa małopolskiego. Oznaczenia indykatorów biologicznych (wskaźnik okrzemkowy) oraz fizykochemicznych (26) zostały wykonane w 2010 r. Wyniki wskazują, że woda potoku zalicza się do I klasy jakości i może być przeznaczona do spożycia przez ludzi, nie jest także zagrożona eutrofizacją. Ponadto po ewentualnym wybudowaniu zbiornik mógłby pełnić rolę kąpieliska.
Pierwsza strona wyników Pięć stron wyników wstecz Poprzednia strona wyników Strona / 1 Następna strona wyników Pięć stron wyników wprzód Ostatnia strona wyników
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.