Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
Pierwsza strona wyników Pięć stron wyników wstecz Poprzednia strona wyników Strona / 1 Następna strona wyników Pięć stron wyników wprzód Ostatnia strona wyników

Wyniki wyszukiwania

help Sortuj według:

help Ogranicz wyniki do:
Pierwsza strona wyników Pięć stron wyników wstecz Poprzednia strona wyników Strona / 1 Następna strona wyników Pięć stron wyników wprzód Ostatnia strona wyników
In our tests we aimed to study the effects of additives normally used in liquid egg products on the calorimetric properties of liquid egg samples. Raw liquid egg white (pH=8.9±0.1), liquid egg yolk (pH=6.5±0.2) and whole liquid egg (pH=7.1±0.2) broken up in industrial conditions were used in our measurements. Sodium benzoate and potassium sorbate were added to the samples to achieve solutions of 0.1, 0.3 and 0.5 g/L concentrations. We used citric acid to prepare liquid egg products with various pH value (5.5, 5.0 and 4.5). The calorimetric tests were performed with MicroDSC III device. Liquid egg samples were heated up from 20°C to 95°C generally with a heating rate of 1.5°C/min. Sample weights were 500 mg±0.1 mg and water was used as reference solution. Evaluation was performed by Seftsoft2000 software, a component of the device. Our measurements have shown significant changes in calorimetric parameters of liquid egg samples by decreasing the pH value to 5.0. In addition to the reduced enthalpy due to acidification of samples, a decrease in denaturation temperature was also observed in the egg white. While the native egg white started to precipitate at 60°C, at pH 5.0 the denaturation was already started at 54.5°C. When sodium benzoate and potassium sorbate were added to liquid egg products a significant change of the tested calorimetric values was only found in the liquid egg samples containing the preservative at the concentration of 0.5 g/L.
In our experiment whole egg powder samples (infected with Salmonella Enteritidis for microbiological tests) were treated at 50.38–54.62°C for 6.41–24.09 h and tested for decrease in Salmonella count or changes in their solubility and colour. Central Composite Rotational Design (CCRD) was used in our tests. In all tests performed within the testing range we achieved a decrease in Salmonella count of at least 5 magnitudes and in cases when the samples were treated at min. 52.5°C for at least 9 h no viable Salmonella could be detected in the whole egg samples at the end of treatments. Our measurements have shown that deterioration of solubility and discolouration was signifi cantly affected only by the temperature change (p<0.05).
Pierwsza strona wyników Pięć stron wyników wstecz Poprzednia strona wyników Strona / 1 Następna strona wyników Pięć stron wyników wprzód Ostatnia strona wyników
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.