Tytuł artykułu

Evaluation of titanium content in mucosa covering two-stage intraosseous implants*

Treść / Zawartość

Warianty tytułu

PL
Ocena zawartości tytanu w błonie śluzowej pokrywającej dwuetapowe wszczepy śródkostne

Języki publikacji

EN

Abstrakty

EN
Widely used biomaterials, including titanium and its alloys, manifest a range of the physicochemical properties which determine the way they are exploited. According to the literature, titanium dental implants, considered biocompatible with the human body, under certain conditions, may cause inflammatory or allergic reactions. The aim of the study has been to evaluate the content of titanium in the mucosa covering two-stage intraosseous implants of the Osteoplant-Hex® system. The content of titanium ions in the examined samples containing segments of mucosa collected from those dental implants was determined with an inductively-coupled plasma emission spectrometer VISTA-MPX produced by VARIAN ICP. A diverse titanium content in the mucosa adjoining the implants has been revealed during their healing period. The determined concentration of titanium ranged from 0.00 to 122.59 μg g–1. As the conducted research suggests, such a wide range may result from differences in the implant location, sex and age of patients. Therefore, the authors tried to find a relationship between the results and those variables.
PL
Szeroko stosowane współcześnie biomateriały, w tym tytan i jego stopy, wykazują wiele cech i właściwości fizykochemicznych, które determinują sposób ich wykorzystania. Jak wynika z piśmiennictwa, wszczepy tytanowe stosowane w stomatologii, uważane za biokompatybilne z ustrojem, mogą w określonych warunkach wywoływać reakcje zapalne lub alergiczne. Celem pracy była ocena zawartości tytanu w błonie śluzowej pokrywającej dwuetapowe wszczepy śródkostne systemu Osteoplant-Hex®. Zawartość jonów tytanu w badanych próbkach zawierających wycinki błony śluzowej pobrane nad wszczepami stomatologicznymi oznaczono na spektrometrze emisyjnym z indukcyjnie sprzężoną plazmą VISTA-MPX firmy VARIAN ICP. Wykazano zróżnicowaną zawartość tytanu w błonie śluzowej kontaktującej się z implantami w okresie ich wgajania. Oznaczono stężenia tytanu od 0,0 do 122,59 μg g–1. Jak wynika z badań, duża rozpiętość wyników może być uzależniona od lokalizacji wszczepu, płci pacjentów, a także wieku, i dlatego podjęto próbę powiązania uzyskanych wyników z kilkoma potencjalnymi parametrami.

Słowa kluczowe

Wydawca

-

Rocznik

Tom

16

Numer

2

Opis fizyczny

p.227-236,fig.,ref.

Twórcy

autor
  • Clinic of Geriatric Dentistry, Karol Marcinkowski University of Medical Sciences, Bukowska 70, 60-812 Poznan, Poland
autor
autor

Bibliografia

  • Czarnobilska E., Obtułowicz K., Wesołek K., Piętowska J., Śpiewak R. 2007. Mechanizmy alergii na nikiel [Mechanisms of allergy to nickel]. Prz. Lek., 64: 502-505. (in Polish)
  • Egusa H., Ko N., Shimazu T., Yatani H. 2008. Suspected association of an allergic reaction with titanium dental implants: a clinical report. J. Prosthet. Dent., 100: 344-347.
  • Friedmann P.C. 2006. Contact sensitization and allergic contact dermatitis: immunobiological mechanism. Toxicol. Lett., 162: 49-54.
  • Lalor P.A., Gray A.B., Wright S., Railton G.T., Freeman M.A., Revell P.A. 1990. Contact sensitivity to titanium in a hip prosthesis? Contact Dermat., 23: 193-19.
  • Müller K., Thon E. V. 2006. Hypersensitivity to titanium: clinical and laboratory evidence. Neuroendocrinol, Lett., 27: 31-35.
  • Orlicki R., Kłaptocz B. 2003. Tytan i jego stopy — właściwości, zastosowanie w stomatologii oraz sposoby przetwarzania [Titanium and its alloyes — properties, application in dentistry and processing techniques]. Inż. Stomat. Biomat., 1: 3-8. (in Polish)
  • Pohler O.E.M. 2000. Unalloyed titanium for implants in bone surgery. Injury Int. J. Care Injured., 31: 7-13.
  • Pryliński M., Limanowska-Shaw H. 2007. Właściwości tytanu i problem nadwrażliwości na ten metal [Properties of titanium and the problem of sensitivity to this metal]. Implanto-protetyka, 4: 50-52. (in Polish)
  • Rusinek B., Stobiecka A., Obtułowicz K. 2008. Alergia na tytan i implanty [Allergy to titanium and implants]. Alergol. Immunol., 5: 5-7. (in Polish)
  • Singh R., Dahotre N.B. 2007. Corrosion degradation and prevention by surface modification of biometallic materials. J. Mater. Sci. Mater Med., 18: 725-751.
  • Stejskal V., Hudecek R., Stejskal J., Sterzl I. 2006. Diagnosis and treatment of metal-induced side-effects. Neuroendocrinol. Lett., 27: 7-16.
  • Stejskal V.D.M., Danersund A., Lindvall A., Hudecek R., Nordman V., Yaqob A., Mayer W., Bieger W., Lindh U. 1999. Metal-specific lymphocytes: biomarkers of sensitivity in man. Neuroendocrinol. Lett., 20: 289-298.
  • Śpiewak R., Brewczyński P. 1993. Powikłania po stabilizacji płytą metalową złamania kości udowej u chorej z alergią kontaktową na chrom, nikiel i kobalt [Complications after stabilisation of a tigh bone’s fraction in a patient allergic to chromium, nickel and cobalt] Pol. Tyg. Lek., 38: 29-30. (in Polish)
  • Śpiewak R. 2007. Alergia kontaktowa — diagnostyka i postępowanie [Contact allergy — diagnosis and treatment]. Alergia, Astma, Immunol., 12: 109-127. (in Polish)
  • Thomas P., Bandl W.D., Maier S., Summer B., Przybilla B. 2006. Hypersensitivity to titanium osteosynthesis with impaired fracture healing, eczema, and T-cell hyperresponsiveness in vitro: case report and review of the literature. Contact Dermat., 55: 199-202.
  • Thon E. V., Müller K., Guzzi G., Kreisel S., Ohnsorge P., Sandkamp M. 2006. LTT-MELISA® is clinically relevant for detecting and monitoring metal sensitivity. Neuroendocrinol. Lett., 27: 17-24.
  • Tomizawa Y., Hanawa T. 2007. Corrosion of pure titanium sternal wire. Ann. Thorac. Surg., 84: 1012-1014.
  • Ungersbock A., Perren S.M., Pohler O. 1994. Comparison of the tissue reaction to implants made of a beta titanium alloy and pure titanium. Experimental study on rabbits. J. Mater. Sci. Mater. Med., 5: 788-792.

Uwagi

PL
Rekord w opracowaniu

Typ dokumentu

Bibliografia

Identyfikatory

Identyfikator YADDA

bwmeta1.element.dl-catalog-c08e3f2b-3bef-44d7-9ae5-9fa70f770128
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.