PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
2011 | 20 | 5 |

Tytuł artykułu

Microbiological air monitoring around municipal wastewater treatment plants

Warianty tytułu

Języki publikacji

EN

Abstrakty

EN
This article presents microbiological air pollution around wastewater treatment plants in Słupca, Kostrzyń, and Września, and the Complex Wastewater Treatment and Wastes Composting Plant in Grodzisk Mazowiecki, Poland. The samples of air were collected using the sedimentation and aspiration methods. The largest group of microorganisms in the monitored air were psychrophilic and mesophilic bacteria and microscopic fungi. The number of psychrophilic bacteria ranged from 78 to 225,000 CFU/m³, the number of mesophilic bacteria varied in the range from 0 to 195,000 CFU/m3 and the fungi – from 0 to 65,700 CFU/m³ of air. The amount of other bacteria (Staphylococcus, Pseudomonas fluorescens, and coliforms) ranged from 0 to 87,500 CFU/m³. A great number of bacteria and fungi has been detected near sewage aeration tanks, places of sludge disposal, and grit chambers. The interpretation of the results has been conducted according to the Polish Standards, which classify the degree of air pollution in reference to the number of microflora in the air. A change in air pollution has been noted depending on the season and climatic conditions (wind strength in particular). Research has shown that coliform bacteria, although not included in the Polish Standard, constitutes a good indicator of microorganisms’ emission from sewage into the air.

Słowa kluczowe

Wydawca

-

Rocznik

Tom

20

Numer

5

Opis fizyczny

p.1243-1250,ref.

Twórcy

  • Institute of Environmental Engineering, Poznań University of Technology, Piotrowo 5, 60-965 Poznań, Poland
autor
  • Institute of Environmental Engineering, Poznań University of Technology, Piotrowo 5, 60-965 Poznań, Poland
  • Institute of Environmental Engineering, Poznań University of Technology, Piotrowo 5, 60-965 Poznań, Poland
  • Institute of Environmental Engineering, Poznań University of Technology, Piotrowo 5, 60-965 Poznań, Poland
autor
  • PPB ROSKON, Fabryczna 9, 62-400 Słupca, Poland

Bibliografia

  • 1. SROCZYŃSKI J., GUMPRECHT J., STROJEK K. Dependence of mortality of industrial agglomeration population on air pollution level. Archives of Environ. Protec. 2, 43, 1992 [In Polish].
  • 2. WARYCH J. Aerosol air pollution problem and its consequences. Ochr Pow Probl Odpad. 33, (3), 93, 1999 [In Polish].
  • 3. DUTKIEWICZ J., GORNY R.L. Biological factors hazardous to human health: classification and criteria of exposure assessment. Med Pr. 53, (1), 29, 2002 [In Polish].
  • 4. TOIVOLA M., ALM S., REPONEN T., KOLARI S., NEVALAINEN A. Personal exposures and microenvironmental concentrations of particles and bioaerosols. J. Environ. Monit. 4, 166, 2002.
  • 5. PASCUAL L., PEREZ-LUZ S., YANEZ M.A., SANTAMARIA A., GIBERT K., SALGOT M., APRAIZ D., CATALAN V. Bioaerosol emission from wastewater treatment plants. Aerobiologia 19, 261, 2003.
  • 6. OPPLIGER A., HILFIKER S., VU DUC T. Influence of seasons and sampling strategy on assessment of bioaerosols in sewage treatment plants in Switzerland. Ann Occup Hyg. 49, (5), 393, 2005.
  • 7. FRACCHIA L., PIETRONAVE S., RINALDI M., MARTINOTTI M.G. Site-related airborne biological hazard and seasonal variations in two wastewater treatment plants. Water Res. 40, 1985, 2006.
  • 8. SANCHEZ-MONEDERO M.A., AGUILAR M.I., FENOLL R., ROIG A. Effect of the aeration system on the levels of airborne microorganisms generated at wastewater treatment plants. Water Res. 42, 3739, 2008.
  • 9. DOUWES J., MANNETJE A., HEEDERIK D. Work-related symptoms in sewage treatment workers. Ann Agric Environ Med. 8, 39, 2001.
  • 10. REPONEN T.A., GAZENKO S.V., GRINSHPUN S.A., WILLEKE K., COLE E.C. Characteristics of Airborne Actinomycete Spores. Appl. Environ. Microbiol. 64, (10), 3807, 1998.
  • 11. KRAJEWSKI J.A., CYPROWSKI M., SZYMCZAK W., GRUCHAŁA J. Health complaints from workplace exposure to bioaerosols: a questionnaire study in sewage workers. Ann Agric Environ Med. 11, 199, 2004.
  • 12. KARRA S., KATSIVELA E. Microorganisms in bioaerosol emissions from wastewater treatment plants during summer at a Mediterranean site. Water Res. 41, 1355, 2007.
  • 13. ORSINI M., LAURENTY P., BONINTI F., ARZANI D., LANNI A., ROMANO-SPICA V. A molecular typing approach for evaluating bioaerosol exposure in wastewater treatment plant workers. Water Res. 36, (5), 1375, 2002.
  • 14. GRISOLI P., RODOLFI M., VILLANI S., GRIGNANI E., COTTICA D., BERRI A., PICCO A.M., DACARRO C. Assessment of airborne microorganism contamination in an industrial area characterized by an open composting facility and a wastewater treatment plant. Environmental Research 109, 135, 2009.
  • 15. BUTAREWICZ A., KOWALUK-KRUPA A. Microbiological air contamination on the sewage storage of city waste area in Augustow. Ochr Pow Probl Odpad. 38, (5), 167, 2004 [In Polish].
  • 16. KRUCZALAK K., OLAŃCZUK-NEYMAN K. Microorganisms in the air over wastewater treatment plants. Pol. J. Environ. Stud. 13, (5), 537, 2004.
  • 17. KRZYSZTOFIK B. Microbiology of the air. Published by Warsaw University of Technology, Warsaw, 1992 [In Polish].
  • 18. MĘDRELA-KUDER E. The occurrence of fungi spores in the atmospheric air in the area of Cracow with regard to dust pollution. Archives of Environ. Protec. 25, (1), 63, 1999 [In Polish].
  • 19. MULLOY K.B. Sewage workers: toxic hazards and health effects. Occup Med. 16, 23, 2001.
  • 20. PILLAI S.D., WIDMER K.W., DOWD S.E., RICKE S.C. Occurrence of airborne bacteria and pathogen indicators during land application of sewage sludge. Appl. Environ. Microbiol. 62, (1), 296, 1996.
  • 21. THORN J., BEIJER L., JONSSON T., RYLANDER R. Measurement strategies for the determination of airborne bacterial endotoxin in sewage treatment plants. Ann Occup Hyg. 46, (6), 549, 2002.
  • 22. HEINONEN-TANSKI H., REPONEN T., KOIVUNEN J. Airborne enteric coliphages and bacteria in sewage treatment plants. Water Res. 43, (9), 2558, 2009.
  • 23. ŠEGVIĆ KLARIĆ M., PEPELJNJAK S. A year-round aeromycological study in Zagreb area, Croatia. Ann Agric Environ Med. 13, 55, 2006.
  • 24. SEURI M., KOIVUNEN J., GRANFORS K., HEINONENTANSKI H. Work-related symptoms and Salmonella antibodies among wastewater treatment plant workers. Epidemiol Infect. 133, 603, 2005.
  • 25. PRAŻMO Z., KRYSIŃSKA-TRACZYK E., SKORSKA C., SITKOWSKA J., CHOLEWA G., DUTKIEWICZ J. Exposure to bioaerosols in a municipal sewage treatment plant. Ann Agric Environ Med. 10, 241, 2003.
  • 26. Journal of Laws No. 87, item 796 [In Polish].
  • 27. Journal of Laws No. 87, item 798 [In Polish].
  • 28. PN-89/Z-04008.08 (Polish Standard). Air purity protection. Sampling methods. Sampling the atmospheric air (imision) for microbiological analysis by aspiration and sedimentation method [In Polish].
  • 29. PN-89/Z-04111.02 (Polish Standard). Air purity protection. Microbiological testings. Determination number of bacteria in the atmospheric air (imision) with sampling by aspiration and sedimentation method [In Polish].
  • 30. PN-89/Z-04111.03 (Polish Standard). Air purity protection. Microbiological testings. Determination number of the fungi in the atmospheric air (imision) with sampling by aspiration and sedimentation method [In Polish].
  • 31. Journal of Laws No. 212, item 1798 [In Polish].
  • 32. Journal of Laws No. 81, item 716 [In Polish].
  • 33. WLAZŁO A., PASTUSZKA J.S., ŁUDZEŃ-IZBIŃSKA B. Assessment of workers’ exposure to airborne bacteria at a small wastewater treatment plant. Med Pr. 53, (2), 109, 2002 [In Polish].
  • 34. LAITINEN S., KANGAS J., KOTIMAA M., LIESIVUORI J., MARTIKAINEN P.J., NEVALAINEN A. Workers’ exposure to airborne bacteria and endotoxins at industrial wastewater treatment plants. Am. Ind. Hyg. Assoc. J. 55, (11), 1055, 1994.
  • 35. MELBOSTAD E., EDUARD W., SKOGSTRAD A., SANDVEN P., LASSEN J., SOSTRAND P. Exposure to bacterial aerosols and work-related symptoms in sewage workers. Am. J. Ind. Med. 25, 59, 1994.
  • 36. BRANDI G., SISTI M., AMAGLIANI G. Evaluation of the environmental impact of microbial aerosols generated by wastewater treatment plants utilizing different aeration systems. J Appl Microbiol 88, 845, 2000.
  • 37. PIEKARSKA K., TRACZEWSKA T.M. Sewage treatment plant influence on microbiological quality of air. Ochr Pow Probl Odpad. 36, (1), 19, 2002 [In Polish].
  • 38. LACCY J., CROOK B. Review: Fungal and actinomycete spores as pollutants of the workplace and occupational allergens. Ann Occup Hyg. 32, 515, 1988.
  • 39. MITAKAKIS T., GUEST D. A fungal spore calendar for the atmosphere of Melbourne, Australia, for the year 1993. Aerobiologia 17, 171, 2001.
  • 40. GORNY R.L., DUTKIEWICZ J. Bacterial and fungal aerosols in indoor environment in Central and Eastern European countries. Ann Agric Environ Med. 9, 17, 2002

Typ dokumentu

Bibliografia

Identyfikatory

Identyfikator YADDA

bwmeta1.element.agro-d6de010a-8107-45a0-8427-0ad8f98616a5
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.