PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
2017 | 26 | 3 |

Tytuł artykułu

Comparing efficiency between conventional and molecular methods for detecting Legionella pneumophilia in dental unit waterline systems

Warianty tytułu

Języki publikacji

EN

Abstrakty

EN
The aim of our study was to detect the prevalence of Legionella pneumophilia (L. pneumophilia) in DUWLS using standard culture technique (SCT) and the real-time polymerase chain reaction (PCR) method in order to assess the risk of L. pneumophilia contamination within a dental setting. A total of 65 water samples were collected from 16 dental units and one cold water supply system from all clinical departments. L. pneumophilia could not be detected in any of the water samples using the standard SCT (0%), whereas L. pneumophilia was detected using real time PCR in three (4.6%) water samples collected from the tap system. Following the detection of L. pneumophilia, the tap systems were disinfected with surface disinfectant and water samples were recollected. The recollected water samples following disinfection were negative for L. pneumophilia once analyzed using culture and real time PCR technique. Although the culture method using BCYE media is the ‘gold standard’ for the detection of L. pneumophilia; Real Time PCR analysis may also be a quick, useful, and sensitive method for the detection of L. pneumophilia in order to control and prevent possible infections that may arise in the dental setting.

Słowa kluczowe

Wydawca

-

Rocznik

Tom

26

Numer

3

Opis fizyczny

p.1419-1423,ref.

Twórcy

autor
  • Department of Pediatric Dentistry, Near East Boulevard, Dentistry Faculty, Near East University Nicosia/North Cyprus, Mersin 10, Turkey, 99138
autor
  • Near East University, Health Services Vocational School, Near East Boulevard, Nicosia/North Cyprus, Mersin 10, Turkey, 99138
autor
  • Department of Infectious Diseases and Clinical Microbiology, Faculty of Medicine, Near East University Near East Boulevard, Nicosia/North Cyprus, Mersin 10, Turkey, 99138
autor
  • Department of Pediatric Dentistry, Near East Boulevard, Dentistry Faculty, Near East University Nicosia/North Cyprus, Mersin 10, Turkey, 99138
autor
  • Near East University, Research Center of Experimental Health Sciences/Celal Bayar University, Faculty of Medicine, Department of Clinical Microbiology, Near East Boulevard, Nicosia/North Cyprus, Mersin 10, Turkey, 99138

Bibliografia

  • 1. LEONI E., DALLOLIO L., STAGNI F., SANNA T., D’ALESSANDRO G., PIANA G. Impact of a risk management plan on Legionella contamination of dental unit water. International Journal of Environmental Research and Public Health. 12 (3), 2344, 2015.
  • 2. SIKORA A., WOJTOWICZ-BOBIN M., KOZIOL-MONTEWKA M., MAGRYS A., GLADLYSZ I. Prevalence of Legionella pneumophila in water distribution systems in hospitals and public buildings of the Lublin region of Eastern Poland. Annals of Agricultural and Enviromental Medicine. 22 (2), 195, 2015.
  • 3. AJAMI B., GHAZVINI K., MOVAHHED T., ARIAEE N., SHAKERI M.T., MAKAREM S. Contamination of a dental unit water line system by Legionella pneumophila in the Mashhad School of Dentistry in 2009. Iranian Red Crescent Medical Journal. 14 (6), 376, 2012.
  • 4. ARVAND M., HACK A. Microbial contamination of dental unit waterlines in dental practices in Hesse, Germany: a cross- sectional study. European Journal of Microbiology and Immunology. 3 (1), 49, 2013.
  • 5. DALLOLIO L., SCUDERI A., RINI M.S., VALENTE S., FARRUGGIA P., BUCCI -SABATTINI M.A., PASQUINELLI G., ACACCI A., RONCARATI G., LEONI E. Effect of different disinfection protocols on microbial and biofilm contamination of dental unit waterlines in community dental practices. International Journal of Environmental Research and Public Health. 11 (2), 2064, 2014.
  • 6. GHOTASLOU R., YEGANEH-SEFIDAN F., AKHI M.T., SOROUSH M.H., HEJAZI M.S. Detection of Legionella contamination in Tabriz hospitals by PCR assay. Advanced Pharmaceutical Bulletin. 3 (1), 131, 2013.
  • 7. CRISTINO S., LEGNANI P.P., LEONI E. Plan for the control of Legionella infections in long-term care facilities: role of enviromental monitoring. International Journal of Hygiene and Environmental Health. 215 (3), 279, 2012.
  • 8. DITOMMASO S., GIACOMUZZI M., RICCIARDI E., ZOTTI C.M. Evidence of Legionella spp. colonization in dental unit waterlines: Which is the best method for risk assessment?. International Journal of Enviromental Research and Public Health. 13 (2), E211. doi: 10.3390/ijerph13020211, 2016.
  • 9. MA’ AYEH S.Y., AL-HIYASAT A.S., HINDIYEH M.Y., KHADER Y.S. Legionella pneumophila contamination of dental unit water line system in a dental teaching centre. International Journal of Dental Hygiene. 6 (1), 48, 2008.
  • 10. DELGADO-VISCOGLIOSI P., SOLIGNAC L., DELATTRE J.M. Viability PCR, a culture-ındependent method for rapid and selective quantification of viable Legionella pneumophila cells in enviromental water samples. Applied and Environmental Microbiology. 75 (11), 3502, 2009.
  • 11. AL-MATAWAH Q.A., AL-ZENKI S.F., QASEM J.A., AL-WAALAN T.E., BEN HEJI A.H. Detection and quantification of Legionella pneumophila from water systems in Kuwait residential facilities. Journal of Pathogens. 138389. doi: 10.1155/2012/138389, 2012.
  • 12. LEE J.V., LAI S., EXNER M., LENZ J., GAIA V., CASATI S., HARTEMANN P., LUCK C., PANGON B., RICCI M.L., SCATURRO M., FONTANA S., SABRIA M., SANCHEZ I., ASSAF S., SURMAN-LEE S. An international trial of quantitative PCR for monitoring Legionella in artificial water systems. Journal of Applied Microbiology. 110 (4), 1032, 2011.
  • 13. TOURON-BODILIS A., POUGNARD C., FRENKIEL-LEBOSSE H., HALLIER-SOULIER S. Usefulness of real-time PCR as a complementary tool to the monitoring of Legionella spp. and Legionella pneumophilaby culture in industrial cooling sysytems. Journal of Applied Microbiology. 111 (2), 499, 2011.
  • 14. BONETTA Sa., BONETTA Si., FERRETTI E., BALOCCO F., CARRARO E. Evaluation of Legionella pneumophila contamination in Italian hotel water systems by quantitative real-time PCR and culture methods. Journal of Applied Microbiology. 108 (5), 1576, 2010.
  • 15. EDAGAWA A., KIMURA A., KAWABUCHI-KURATA T., ADACHI S., FURUHATA K., MIYAMOTO H. Investigation of Legionella contamination in bath water samples by culture, amoebic co-culture, and real time quantitative PCR methods. International Journal of Environmental Research and Public Health. 12 (10), 13118, 2015.
  • 16. DITOMMASO S., RICCIARDI E., GIACOMUZZI M., ARAUCO-RIVERA S.R., CECARELLI A., ZOTTI C.M. Overestimation of the Legionella spp. load in enviromental samples by quantitative real-time PCR: pretreatment with propidiummonoazide as a tool for the assessment of an association between Legionella concentration and sanitary risk. Diagnostic Microbiology and Infectious Disease. 80 (4), 260, 2014.
  • 17. KRAMER A., LEMANSKI S., DEMOND K., ASSADIAN O. Comparison of the ActiDes-Blue and CARELA HYDRODES techonology for the sanitation of contaminated cooling water systems in dental units. GMS Krankenhaushygiene Interdisziplinar. 7 (1), ISSN 1863-5245, 2012.
  • 18. DITOMMASO S., RICCIARDI E., GIACOMUZZI M., ARAUCO-RIVERA S.R., ZOTTI C.M. Legionella in water samples: how can you interpret the results obtained by quantitative PCR? Molecular and Cellular Probes. 29 (1), 7, 2015.
  • 19. GARG S.K., MITTAL S., KAUR P. Dental unit waterline management: historical perspectives and current trends. Oral Biosciences. 3 (4), 247, 2012.
  • 20. BODRUMLU E., ALAÇAM T., BAYRAKTAR A. Legionella in the dental office. International Journal of Dental Hygiene. 5 (2), 116, 2007.
  • 21. GÜNGÖR N.D., KADAIFÇILER D.G., PEKER O.Ö. Investigation of the bacterial load and antibiotic susceptibility of dental units. Enviromental monitoring and assessment. 186 (3), 1847, 2014.

Typ dokumentu

Bibliografia

Identyfikatory

Identyfikator YADDA

bwmeta1.element.agro-c0257071-92ed-448b-91c3-92e6b762a4ac
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.