PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
2016 | 72 | 02 |

Tytuł artykułu

Możliwości operacyjnego leczenia złamań trzonu kości śródręcza trzeciej u koni

Warianty tytułu

EN
Diaphyseal fractures of third metacarpal bone: Possible surgical treatment in horses

Języki publikacji

PL

Abstrakty

EN
Diaphyseal fractures of the third metacarpal bone (MC III – metacarpus III) are a major challenge for the veterinarian. Because these bones have minimal soft-tissue coverage, there is a high risk of open fracture and subsequent infection. Among all methods of osteosynthesis used for the treatment of diaphyseal fractures of the MC III in horses, the most popular uses metal plates attached to the bone surface. Unfortunately, there is a fundamental problem associated with plate osteosynthesis, since the attachment of two such plates requires the use of 20-24 screws, which involves substantial tissue trauma and wound closing difficulties. Another important issue is the fact that the fixation is too stiff, which prolongs the time of new bone formation and therefore healing. The most serious complications that occur after this type of surgery are infections and the screws loosening in the bone. They are also the common cause of failure in bone fracture treatment in horses. The duration of surgery is another problem in horses, because osteosynthesis prolongs general anesthesia, which may result in postanaesthetic myositis and circulation disorders. There is also the risk of osteosynthesis break-up when the horse manages to stand up after the first (main) or second (screw removing) surgery. Moreover, plates cannot be applied in the case of open or infected fractures. These difficulties make it necessary to search for better solutions, including the use of external fixators. Their main advantages are the quick insertion of implants and limited tissue trauma associated with it. The removal of implants is easy and does not require general anesthesia. Because of the lack of direct contact with the fixators (except for the pins), the blood supply to bone is not obstructed, which is beneficial for healing. External fixators can be used in the treatment of open fractures, which are often contaminated and infected. So far, no dedicated fixator for the treatment of diaphyseal fractures of MC III in horses is available on the market. The authors of this article have developed a fixator designed specifically for the treatment of diaphyseal fractures of MC III, which has successfully passed strength tests.

Wydawca

-

Rocznik

Tom

72

Numer

02

Opis fizyczny

s.87-91,bibliogr.

Twórcy

autor
  • Katedra Chorób Dużych Zwierząt z Kliniką, Wydział Medycyny Weterynaryjnej, Szkoła Główna Gospodarstwa Wiejskiego w Warszawie, ul. Nowoursynowska 166, 02-787 Warszawa
  • Katedra Chorób Dużych Zwierząt z Kliniką, Wydział Medycyny Weterynaryjnej, Szkoła Główna Gospodarstwa Wiejskiego w Warszawie, ul. Nowoursynowska 166, 02-787 Warszawa

Bibliografia

  • Aithal H. P., Kinjavdekar P., Amarpal, Pawde A. M., Singh G. R., Setia H. Ch.: Management of tibial fractures using a circular external fixator in two calves. Vet. Surg. 2010, 39, 621-626.
  • Auer J. A.: Metacarpal (-tarsal) shaft, [w:] Fackelman G. E., Auer J. A., Nunamaker D. M. (red.:) AO principles of equine osteosynthesis. Wyd. 1. Thieme, Stuttgart 2000, s. 179-195.
  • Auer J. A.: Principles of fracture treatment, [w:] Auer J. A., Stick J. A. (red.): Equine surgery. Wyd. 3. St. Louis: Saunders Elsevier 2006, s. 1000-1029.
  • Auer J. A.: Special implants: DCS/DHS, LC-DCP, LC-Plates. Mat. 80. kursu AO: Fracture treatment in large animals: advances in AO techniques. Davos, Szwajcaria 2004, s. 18-22.
  • Auer J. A.: The locking compression plate (LCP). Proceedings of the European Society of Veterinary Orthopaedics and Traumatology 2008, s. 206-210.
  • Bischofberger A. S., Furst A., Auer J., Lischer C.: Surgical management of complete diaphyseal third metacarpal and metatarsal bone fractures: clinical outcome in 10 mature horses and 11 foals. Equine Vet. J. 2009, 9, 465-473..
  • Carpenter R. S., Galuppo L. D., Simpson E. L., Dowd J. P.: Clinical evaluation of the locking compression plate for fetlock arthrodesis in six thoroughbred racehorses. Vet. Surg. 2008, 37, 263-268.
  • Cervantez C., Madison J. B., Miller G. J., Casar R. S.: An in vitro biomechanical study of a multiplanar circular external fixator applied to equine third metacarpal bones. Vet. Surg. 1996, 25, 1-5
  • Fitch G. L., Galuppo L. D., Stover S. M., Willits N. H.: An in vitro biomechanical investigation of an intramedullary nailing technique for repair of third metacarpal and metatarsal fractures in neonates and foals. Vet. Surg. 2001, 30, 422-431.
  • Florin M., Arzdorf M., Linke B.: Assessment of stiffness and strength of four different implants available for equine fracture treatment: A study on a 20-degree oblique long bone fracture model using a bone substitute. Vet. Surg. 2005, 34, 231-237.
  • Galuppo L. D., Stover S. M., Aldridge A., Hewes C., Tylor K. T.: An in vitro biomechanical investigation of an MP35N intramedullary interlocking nail system for repair of third metacarpal fractures in adult horses. Vet. Surg. 2002, 31, 211-225.
  • Godoy R. F. de, Filgueiras R. R., Gontijo L. A., Ximenes F. H. Bezerra, De Gouvea L. V., Pereira C. S., Almeida R. M., Leite C. R., Neto A. R. T., Borges J. R. J.: Treatment of a periarticular tibial fracture in a foal with a hybrid external fixator. Veterinary Surgery 2009, 38, 650-653.
  • Herthel D. J.: Aplication of the interlockoing intramedullary nail, [w:] Nixon A. J. (red.): Equine fracture repair. 1st edition, W. B. Saunders, Philadelphia 1996, s. 371-376.
  • Joyce J., Baxter G. M., Sarrafian T. L., Stashak T. S., Trotter G., Frisbie D.: Use of transfixation pin casts to treat adult horses with comminuted phalangeal fractures: 20 cases (1993-2003). J. Am. Vet. Med. Assoc. 2006, 229, 725-730.
  • Leskun T. B., McClure S. R., Ward M. P., Downs C., Wilson D. A., Adams S. B., Hawkins J. F., Reinertson E. L.: Evaluation of transfixation casting for treatment of third metacarpal, third metatarsal, and phalangeal fractures in horses: 37 cases (1994-2004). J. Am. Vet. Med. Assoc. 2007, 230, 1340-1349.
  • Levine D. G., Richardson D. W.: Clinical use of the locking compression plate (LCP) in horses: retrospective study of 31 cases (2004-2006). Equine Vet. J. 2007, 39, 401-406.
  • McClure S. R., Hillberry B. M., Fischer K. E.: In vitro comparison of metaphyseal and diaphyseal placement of centrally threaded, positive-profile transfixation pins in the equine third metacarpal bone. Am. J. Vet. Res. 2000, 61, 1304-1308.
  • McClure S. R., Watkins J. P., Ashman R. B.: In vitro comparison of the effect of parallel and divergent transfixation pins on breaking strength of equine third metacarpal bones. Am. J. Vet. Res. 1994 a, 55, 1327-1330.
  • McClure S. R., Watkins J. P., Ashman R. B.: In vivo evaluation of intramedullary interlocking nail fixation of transverse femoral osteotomies in foals. Vet. Surg. 1998a, 27, 29-36.
  • McClure S. R., Watkins J. P., Bronson D. G., Ashman R. B.: In vitro comparison of the standard short limb cast and three configurations of short limb transfixation casts in equine forelimbs. Am. J. Vet. Res. 1994 b, 55, 1331-1334.
  • McClure S. R., Watkins J. P., Glickman N. W., Hawkins J. F., Glickman L. T.: Complete fractures of the third metacarpal or metatarsal bone in horses: 25 cases (1980-1986). J. Am. Vet. Med. Assoc. 1998b, 213, 847-850.
  • McDuffee L., Stover S., Taylor K., Les C.: An in vitro biomechanical investigation of an interlocking nail for fixation of diaphyseal tibial fractures in adult horses. Veterinary Surgery 1994, 23, 219-230.
  • Morisset S., McClure S. R., Hillberry B. M., Fisher K. E.: In vitro comparison of the use of two large-animal, centrally threaded, positive-profile transfixation pin designs in the equine third metacarpal bone. Am. J. Vet. Res. 2000, 61, 1298-1303.
  • Nemeth F., Back W.: The use of the walking cast to repair fractures in horses and ponies. Equine Vet. J. 1991, 23, 32-36.
  • Nunamaker D. M., Nash R. A.: A tapered-sleeve transcortical pin external skeletal fixation device for use in horses: development, application, and experience. Vet. Surg. 2008, 37, 725-732. 1986, 15, 345-355.
  • Payne R. J., Compson P. C.: Short and long – term results following standing fracture repair in 34 horses. Equine Vet. J. 2012, 44, 721-725.
  • Ramotowski W., Granowski R., Bielawski J.: Osteosynteza metodą Zespol. Teoria i praktyka kliniczna. PZWL, Warszawa 1988, s. 9-15.
  • Richardson D. M.: External skeletal fixation in horses. Materiały 80 kursu AO: Fracture treatment in large animals: advances in AO techniques. Davos, Szwajcaria 2004, s. 16-17.
  • Richardson D. M.: The metacarpal and metatarsal bones, [w:] Auer J. A., Stick J. A. (red.): Equine surgery. St. Louis: Saunders Elsevier 2006, s. 1238-1253.
  • Russell T. M., Maclean A. A.: Standing surgical repair of propagating metacarpal and metatarsal condylar fractures in racehorses. Equine Vet. J. 2006, 38, 423-427.
  • Schneider R. K., Jackman B. R.: Fractures of the third metacarpus and metatarsus, [w:] Nixon A. J. (red.): Equine Fracture Repair. Wyd. 1. W. B. Saunders. Philadelphia 1996, s. 179-194.
  • Sod G. A., Hubert J. D., Martin G. S., Gill M. S.: An in vitro biomechanical comparison between prototype tapered shaft cortical bone screws and AO cortical bone screws for an equine metacarpal dynamic compression plate fixation of ostheotomized equine third metacarpal bones. Vet. Surg. 2006, 35, 634-642.
  • Sod G. A., Hubert J. D., Martin G. S., Gill M. S.: An in vitro biomechanical comparison of a limited contact-dynamic compression plate fixation with a dynamic compression plate fixation of ostheotomized equine third metacarpal bones. Vet. Surg. 2005a, 34, 579-586.
  • Sod G. A., Hubert J. D., Martin G. S., Gill M. S.: An in vitro biomechanical comparison of a prototype equine metacarpal dynamic compression plate fixation with double dynamic compression plate fixation of ostheotomized equine third metacarpal bones. Vet. Surg. 2005b, 34, 594-603.
  • Sod G. A., Mitchell C. F., Hubert J. D., Martin G. S., Gill M. S.: In vitro biomechanical comparison of a 5.5 mm limited-contact dynamic compression plate fixation with a 4.5 mm limited-contact dynamic compression plate fixation of osteotomized equine third metacarpal bones. Vet. Surg. 2008, 37, 289-293.
  • Sod G. A., Mitchell C. F., Hubert J. D., Martin G. S., Gill M. S.: In vitro biomechanical comparison of locking compression plate fixation and limited-contact dynamic compression plate fixation of osteotomized equine third metacarpal bones. Vet. Surg. 2008, 37, 283-288.
  • Specht T. E., Miller G. J., Colahan P. T.: Effects of clustered drill holes on the breaking strength of the equine third metacarpal bone. Am. J. Vet. Resarch. 1990, 51, 1242-1246.
  • Sullins K. E., McIlwraith C. W.: Evaluation of 2 types of external skeletal fixation for repair of experimental tibial fractures in foals. Vet. Surg. 1987, 16, 4, 255-264.
  • Watkins J. P.: Transfixation casting: Indications and techniques. Materiały 76 kursu AO. Fracture treatment in large animals: Principles and new concepts. Davos, Szwajcaria 2002, s. 27-28.
  • Zacharias J. R., Lescun T. B., Moore G. E., Van Sickle D. C.: Comparison of insertion characteristic of two types of hydroxyapatite-coated and uncoated positive profile transfixation pins in the third metacarpal bone of horses. Am. J. Vet. Res. 2007, 68, 11, 1160-1166.

Typ dokumentu

Bibliografia

Identyfikatory

Identyfikator YADDA

bwmeta1.element.agro-ba14f99d-1a97-44db-bf15-7dc629cb08f7
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.