PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
2020 | 76 | 10 |

Tytuł artykułu

Protective effects of hydrogen on oxidative stress and liver function during CO2 pneumoperitoneum in dogs

Warianty tytułu

Języki publikacji

EN

Abstrakty

EN
The purpose of this study was to investigate the protective effects of hydrogen reducing ischemia-reperfusion injury during CO2 pneumoperitoneum on oxidative stress and liver function. Eighteen healthy Beagle dogs were divided into three groups. Dogs in the control group were subjected only to anesthesia for 90 min. The pneumoperitoneum group was subjected to the pressure of CO2 pneumoperitoneum with 12 mmHg intraabdominal pressure for 90 min. The hydrogen group was subjected to the pressure of CO2 pneumoperitoneum with 12 mmHg intra-abdominal pressure for 90 min after a subcutaneous injection of hydrogen gas (0.2 mL/kg) for 10 min. Blood samples were collected before the induction of pneumoperitoneum, as well as 2 h and 6 h after deflation, to evaluate oxidative stress and liver function in serum. Liver tissue samples were taken 6 h after deflation for histopathological examination. In comparison with group P, a milder histopathological change was found in group H2, and the levels of hepatic function and anti-oxidation in group H2 were higher. Hydrogen gas reduced liver ischemia-reperfusion injury due to CO2 pneumoperitoneum by reducing oxidative stress and improving liver function. Hydrogen gas therapy can be considered as a way to reduce liver ischemiareperfusion injury in laparoscopic surgery.

Słowa kluczowe

Wydawca

-

Rocznik

Tom

76

Numer

10

Opis fizyczny

p.589-592,fig.,ref.

Twórcy

autor
  • College of Veterinary Medicine, Northeast Agricultural University, Harbin 150030, China
  • China and Heilongjiang Key Laboratory for Laboratory Animals and Comparative Medicine, Harbin 150030, China
autor
  • College of Veterinary Medicine, Northeast Agricultural University, Harbin 150030, China
  • China and Heilongjiang Key Laboratory for Laboratory Animals and Comparative Medicine, Harbin 150030, China
autor
  • College of Veterinary Medicine, Northeast Agricultural University, Harbin 150030, China
  • China and Heilongjiang Key Laboratory for Laboratory Animals and Comparative Medicine, Harbin 150030, China
autor
  • College of Veterinary Medicine, Northeast Agricultural University, Harbin 150030, China
  • China and Heilongjiang Key Laboratory for Laboratory Animals and Comparative Medicine, Harbin 150030, China
autor
  • College of Veterinary Medicine, Northeast Agricultural University, Harbin 150030, China
  • China and Heilongjiang Key Laboratory for Laboratory Animals and Comparative Medicine, Harbin 150030, China

Bibliografia

  • 1. Bast A., Haenen G. R. M. M., Doelman C. J. A.: Oxidants and antioxidants: state of the art. Am. J. Med. 1991, 91, 2S-13S.
  • 2. Casini A., Ceni E., Salzano R., Biondi P., Parola M., Galli A., Foschi M., Caligiuri A., Pinzani M., Surrenti C.: Neutrophil-derived superoxide anion induces lipid peroxidation and stimulates collagen synthesis in human hepatic stellate cells: Role of nitric oxide. Hepatology 1997, 25, 361-367.
  • 3. Cevrioglu A. S., Yilmaz S., Koken T., Tokyol C., Yilmazer M., Fenkci I. V.: Comparison of the effects of low intra-abdominal pressure and ischaemic preconditioning on the generation of oxidative stress markers and inflammatory cytokines during laparoscopy in rats. Hum. Reprod. 2004, 19, 2144-2151.
  • 4. Coisman J. G., Case J. B., Shih A., Harrison K., Isaza N., Ellison G.: Comparison of surgical variables in cats undergoing single-incision laparoscopic ovariectomy using a LigaSure or extracorporeal suture versus open ovariectomy. Vet. Surg. 2014, 43, 38-44.
  • 5. Davidson E. B., Moll H. D., Payton M. E.: Comparison of laparoscopic ovariohysterectomy and ovariohysterectomy in dogs. Vet. Surg. 2004, 33, 62-69.
  • 6. Fukuda K., Asoh S., Ishikawa M., Yamamoto Y., Ohsawa I., Ohta S.: Inhalation of hydrogen gas suppresses hepatic injury caused by ischemia/reperfusion through reducing oxidative stress. Biochem. Biophys. Res. Commun. 2007, 361, 670-674.
  • 7. Gandini M., Giusto G.: Laparoscopic single-port ovariectomy and gastropexy in dogs. Schweiz. Arch. Tierheilkd. 2016, 158, 755-758.
  • 8. Gutt C. N., Schmedt C. G., Schmandra T., Heupel O., Schemmer P., Buchler M. W.: Insufflation profile and body position influence portal venous blood flow during pneumoperitoneum. Surg. Endos. 2003, 17, 1951-1957.
  • 9. Guzel O., Erdikmen D. O., Aydin D., Mutlu Z., Yildar E.: Investigation of the effects of CO2 insufflation on blood gas values during laparoscopic procedures in pigs. Turk. J. Vet. Anim. Sci. 2012, 36, 183-187.
  • 10. Huang Y., Xie K., Li J., Xu N., Gong G., Wang G., Yu Y., Dong H., Xiong L.: Beneficial effects of hydrogen gas against spinal cord ischemia-reperfusion injury in rabbits. Brain Rese. 2011, 1378, 125-136.
  • 11. Huhn J. C.: Advances in equipment and instrumentation in laparoscopic surgery. Vet. Clin. North Am. Small Anim. Pract. 2016, 46, 13-29.
  • 12. Ishibashi T.: Molecular hydrogen: new antioxidant and anti-inflammatory therapy for rheumatoid arthritis and related diseases. Curr. Pharm. Design. 2013, 19, 6375-6381.
  • 13. Jaeschke H., Farhood A.: Neutrophil and Kupffer cell-induced oxidant stress and ischemia-reperfusion injury in rat liver. Am. J. Physiol. 1991, 260, 355-362.
  • 14. Ji X., Liu W., Xie K., Liu W., Qu Y., Chao X., Chen T., Zhou J., Fei Z.: Beneficial effects of hydrogen gas in a rat model of traumatic brain injury via reducing oxidative stress. Brain Res. 2010, 1354, 196-205.
  • 15. Kuntz C., Wunsch A., Bodeker C., Bay F., Rosch R., Windeler J., Herfarth C.: Effect of pressure and gas type on intraabdominal, subcutaneous, and blood pH in laparoscopy. Surg. Endos. 2000, 14, 367-371.
  • 16. Lee J. Y., Choi S. H.: Results of hepatic and renal function tests to different CO2 pneumoperitoneum conditions: An experimental capnoperitoneum study in dogs. Res. Vet. Sci. 2015, 101, 1-5.
  • 17. Liu L., Xie K., Chen H., Dong X., Li Y., Yu Y., Wang G., Yu Y.: Inhalation of hydrogen gas attenuates brain injury in mice with cecal ligation and puncture via inhibitoring neuroinflammation, oxidative stress and neuronal apoptosis. Brain Res. 2014, 1589, 78-92.
  • 18. Mayhew P. D., Mehler S. J., Mayhew K. N., Steffey M. A., Culp W. T.: Experimental and clinical evaluation of transperitoneal laparoscopic ureteronephrectomy in dogs. Vet. Surg. 2013, 42, 565-571.
  • 19. Morino M., Giraudo G., Festa V.: Alterations in hepatic function during laparoscopic surgery. Surg. Endos. 1998, 12, 968-972.
  • 20. Ohsawa I., Ishikawa M., Takahashi K., Watanabe M., Nishimaki K., Yamagata K., Katsura K., Katayama Y., Asoh S., Ohta S.: Hydrogen acts as a therapeutic antioxidant by selectively reducing cytotoxic oxygen radicals. Nat. Med. 2007, 13, 688-694.
  • 21. O’Malley C., Cunningham A. J.: Physiologic changes during laparoscopy. Anesthesiol Clin. North America. 2001, 19, 1-19.
  • 22. Sammour T., Mittal A., Loveday B. P., Kahokehr A., Phillips A. R., Windsor J. A., Hill A. G.: Systematic review of oxidative stress associated with pneumoperitoneum. Brit. J. Surg. 2009, 96, 836-850.
  • 23. Szold A., Weinbroum A. A.: Carbon dioxide pneumoperitoneum-related liver injury is pressure dependent: A study in an isolated-perfused organ model. Surg. Endos. 2008, 22, 365-371.
  • 24. Yamada T., Grisham M. B.: Role of neutrophil-derived oxidants in the pathogenesis of intestinal inflammation. Wien Klin. Wochenschr. 1991, 69, 988-994.
  • 25. Yoshida M., Ikeda S., Sumitani D., Takakura Y., Yoshimitsu M., Shimomura M., Noma M., Tokunaga M., Okajima M., Ohdan H.: Alterations in portal vein blood pH, hepatic functions, and hepatic histology in a porcine carbon dioxide pneumoperitoneum model. Surg. Endos. 2010, 24, 1693-1700.
  • 26. Zhang J. T., Wang H. B., Shi J., Zhang N., Zhang S. X., Fan H. G.: Laparoscopy for percutaneous tube cystostomy in dogs. J. Am. Vet. Med. A. 2010, 236, 975-977.

Typ dokumentu

Bibliografia

Identyfikatory

Identyfikator YADDA

bwmeta1.element.agro-b2eb0099-da5a-4964-b9ae-7ae2e4ff9f1d
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.