PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
2005 | 12 | 2 |

Tytuł artykułu

Bacterial contamination of indoor air, surfaces, and settled dust, and related dust endotoxin concentrations in healthy office buildings

Treść / Zawartość

Warianty tytułu

Języki publikacji

EN

Abstrakty

EN
Endotoxin, a characteristic external fraction of the outer membrane from Gram-negative bacteria, continuously shed into the environment, is considered as an important risk factor for human health. Our purpose was to study the bacterial species contaminating healthy working environments. Airborne, working surfaces and carpet dust samples were collected from 25 offices. Bacterial species were identified with biochemical ApiSystem® strips. Endotoxin concentrations in settled dust were measured with the kinetic chromogenic Limulus assay. The airborne bacterial level varied from 44-2,511, with a median of 277 cfu/m3. Bacterial contamination on surfaces ranged from 1-1000, with 33 cfu/25 cm2 as median value. On carpets, bacterial concentration ranged from 0.73-185 x 105 cfu/g, with 7.28 x 105 cfu/g as median value. Endotoxin concentration varied from 4.6-116.2 EU/mg, with a median of 20.3 EU/mg. Altogether, 501 bacterial strains were isolated. The species variability was greater in Gram-negative bacteria than in Gram-positive cocci with 41 versus 34 various species. In conclusion, people working in healthy offices can be exposed to large concentrations of airborne and dust bacteria and related endotoxin concentrations, giving a risk of work-related diseases.

Wydawca

-

Rocznik

Tom

12

Numer

2

Opis fizyczny

p.187-192,ref.

Twórcy

autor
  • Universite Libre de Bruxelles, Campus Plaine, CP 205/2, Boulevard du Triomphe, B-1050 Bruxelles, Belgique
autor
autor

Bibliografia

  • 1. Bholah R, Subratty A: Indoor biological contaminants and symptoms of sick building syndrome in office buildings in Mauritius. Int J Environ Health Res 2002, 12(1), 93-98.
  • 2. Böttcher M, Björkstén В, Gustafson S, Voor T, Jenmalm M: Endotoxin levels in Estonian and Swedish house dust and atopy in infancy. Clin Exp Allergy 2003, 33, 295-300.
  • 3. Dacarro C, Picco A, Grisoli P, Rodolfi M: Determination of aerial microbiological contamination in scholastic sports environments. J Appl Microbiol 2003, 95, 904-912.
  • 4. DeLucca A, Godshall M, Palmgren M: Gram-negative bacterial endotoxins in grain elevator dusts. Am Ind Ну g Assoc J 1984, 45(5), 336-339.
  • 5. Douwes J, Zuidhof A, Doekes G, Van Der Zee S, Wouters I, Boezen M, Brunekreef B: (1—>3)-ß-D glucan and endotoxin in house dust and peak flow variability in children. Am J Respir Crit Care Med 2000,162, 1348-1354.
  • 6. Dutkiewicz J, Olenchock S, Sorenson W, Gerencser V, May J, Pratt D, Robinson V: Levels of bacteria, fungi and endotoxin in bulk and aerosolized corn silage. Appl Environ Microbiol 1989, 55(5), 1093-1099.
  • 7. Dutkiewicz J: Bacteria and fungi in organic dust as potential health hazard. Ann Agric Environ Med 1997, 4, 11-16.
  • 8. Dutkiewicz J, Krysińska-Traczyk E, Prażmo Z, Skórska C, Sitkowska J: Exposure to airborne microorganisms in Polish sawmills. Ann Agric Environ Med 2001, 8, 71-80.
  • 9. Dutkiewicz J, Krysińska-Traczyk E, Skórska C, Sitkowska J, Prażmo Z, Golec M: Exposure to airborne microorganisms and endotoxin in herb processing plants. Ann Agric Environ Med 2001, 8, 201-211.
  • 10. Dutkiewicz J, Olenchock S, Krysińska-Traczyk E, Skórska C, Sitkowska J, Prażmo Z: Exposure to airborne microorganisms in fiberboard and chipboard factories. Ann Agric Environ Med 2001, 8, 191-199.
  • 11. Dutkiewicz J, Krysińska-Traczyk E, Skórska C, Cholewa G, Sitkowska J: Exposure to airborne microorganisms and endotoxin in a potato processing plant. Ann Agric Environ Med 2002, 9, 225-235.
  • 12. Gehring U, Bischof W, Fahlbusch В, Wichmann H, Heinrich J: House dust endotoxin and allergic sensitizationin children. Am J Respir Crit Care Med 2002,166, 939-944.
  • 13. Górny R, Dutkiewicz J: Bacterial and fungal aerosols in indoor environment in Central and Eastern European countries. Ann Agric Environ Med 2002, 9, 17-23.
  • 14. Horak B, Dutkiewicz J, Solarz K: Microflora and acarofauna of bed dust from homes in Upper Silesia, Poland. Ann Allergy Asthma Immunol 1996, 76(1), 41-50.
  • 15. Jacobs R: Endotoxin in the environments. Int J Occup Environ Health 1997, 3, SI3-5.
  • 16. Krysińska-Traczyk E, Skórska C, Cholewa G, Sitkowska J, Milanowski J, Dutkiewicz J: Exposure to airborne microorganisms in furniture factories. Ann Agric Environ Med 2002, 9, 85-90.
  • 17. Li C, Hsu C, Tai M: Indoor pollution and sick building syndrome symptoms among workers in day-care centers. Arch Environ Health 1997, 52(3), 200-7.
  • 18. Macher J: Review of methods to collect settled dust and isolate culturable microorganisms. Indoor Air 2001, 11(2), 99-110.
  • 19. Martinez F, Holt P: Role of microbial burden in aetiology of allergy and asthma. Lancet 1999, 354, Sill2-5.
  • 20. McDonald J, Armstrong B, Bénard J, Cherry N, Farant J: Sick building syndrome in a Canadian office complex. Arch Environ Health 1993, 48(5), 298-304.
  • 21. Mendell M, Fisk W, Kreiss K, Levin H, Alexander D, Cain W, Girman J, Hines C, Jensen P, Milton D, Rexroat L, Wallingford K: Improving the health workers in indoor environments: priority research needs for a national occupational research agenda. Am J Public Health 2002, 92(9), 1430-1440.
  • 22. Michel O, Kips J, Duchateau J, Vertongen F, Robert L, Collet H, Pauwels R, Sergysels R: Severity of asthma is related to endotoxin in house dust. Am J Respir Crit Care Med, 1996,154, 1641-1646.
  • 23. Ooi P, Goh K: Sick building syndrome an emerging stress-related disorder? Int J Epidemiol 1997, 26(6), 1243-1249.
  • 24. Park J, Gold D, Spiegelman D, Bürge H, Milton D: House dust endotoxin and wheeze in the first year of life. Am J Respir Crit Care Med 2001,163, 322-328.
  • 25. Prażmo Z, Krysińska-Traczyk E, Skórska C, Sitkowska J, Cholewa G, Dutkiewicz J: Exposure to bioaerosols in a municipal sewage treatment plant. Ann Agric Environ Med 2003, 10, 241-248.
  • 26. Reynolds S, Black D, Borin S, Breuer G, Burmeister L, Fuortes L, Smith T, Stein M, Subramanian P, Thorne P, Whitten P: Indoor environmental quality in six commercial office buildings in the midwest United States. Appl Occup Environ Hyg 2001, 16(11), 1065-1077.
  • 27. Rylander R: Health effects among workers in sewage treatment plants. Occup Environ Med 1999, 56, 354-357.
  • 28. Sessa R, Di P, Schiavoni G, Santino I, Altieri A, Pinelli S, Del P: Microbiological indoor air quality in healthy buildings. New Microbiol 2002, 25(1), 51-56.
  • 29. Shen Y, Sorenson W, Levis D, Olenchock S: Microbiological analyses ans inflammatory effects of settled dusts from rice and hay. Biomed Environ Sci 1990, 3(3), 353-363.
  • 30. Von Mutius E, Braun-Fahrländer C, Schierl R, Riedler J, Ehlermann S, Maisch S, Waser M, Nowak D: Exposure to endotoxin or other bacterial components might protect against the development of atopy. Clin Exp Allergy 2000, 30, 1230-1234.
  • 31. Wickens K, Douwes J, Siebers R, Fitzharris P, Wouters I, Doekes G, Mason K, Hearfield M, Cunningham M, Crane J: Determinants of endotoxin levels in carpets in New Zealand homes. Indoor Air 2003, 13, 128-135.
  • 32. Wilson S, Morrow-Tesch J, Straus D, Cooley J, Wong W, Mitlöhner F, McGlone J: Airborne microbial flora in a cattle feedlot. Appl Environ Microbiol 2002, 68(7), 3238-3242.
  • 33. Zucker В, Trojan S, Müller W: Airborne Gram-negative bacterial flora in animal houses. J Vet Med В Infect Dis Vet Public Health 2000, 47(1), 37-46.

Typ dokumentu

Bibliografia

Identyfikatory

Identyfikator YADDA

bwmeta1.element.agro-article-e581df5f-9b3d-413f-888a-a3bc2b2e10e0
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.