Porous ceiling air inlet as a potential source of uncontrolled air exchange at nurseries with exhaust mechanical ventilation

Warianty tytułu

Języki publikacji

EN

Abstrakty

EN
The purpose of the research was to compare uncontrolled air exchange at nurseries with different air inlet solution. Four identical 400 m2 nursery departments were investigated. Three of them used porous ceiling as an air inlet, with different area of ceiling designed to be permeable. The areas of porous ceiling tested were 300, 150 and 75 m2 respectively. In fourth department ventilation air entered the room through, also located in the ceiling, high speed inlet systems. Actual air exchange in the departments was evaluated from H2O balance. The data required for calculation, i.e. inside and outside temperatures and humidities were being continuously monitored and registered from mid of December, 2000 to early February, 2001 to include first 5 weeks after moving piglets to each departments. Propane consumption was checked every day. U – value for the outside walls was calculated and additionally checked by means of thermovision.

Wydawca

-

Rocznik

Tom

05

Numer

1

Opis fizyczny

http://www.ejpau.media.pl/series/volume5/issue1/engineering/art-02.html

Twórcy

autor
  • University of Zielona Gora, 15 Prof.Z.Szafran Street, 65-516 Zielona Gora, Poland
autor

Bibliografia

  • Barber E. M., 1987. Improved Swine Barn Ventilation Systems. Paper prepared for 1986-1987 Annual Report of the Prairie Swine Center, Saskatoon, 10 pp.
  • Barber E. M., Ogilvie J. R., 1984. Incomplete Mixing in Ventilated Airspaces. Part II. Scale Model Study. Can. Agic. Eng. 26, 189-196.
  • Bartussek H., 1981. Porenlüftung. Österreichische Kuratorium für Landtechnik, Wien, 143 pp.
  • Brunsell J. T., 1994. The Performance of Dynamic Insulation in Two Residential Buildings. Proc. 15th AIVC Conference, Buxton, UK (supplement).
  • CIGR, 1984. CIGR Working Group Report on Climatization of Animal Houses, Aberdeen.
  • Graee T., 1974. Breathing Building Construction. ASAE paper No. 74-4057, St Joseph, MI 49085, 13 pp.
  • Graee T., 1988. Breathing Building Constructions, Properties, Experiences and Possibilities in Norway. Internationales Symposium über porenlüftung, BAL Gumpenstein, Austria.
  • Honey L. F. Wrubleski E. M., 1977. An Evaluation of a Porous Ceiling in a Free Stall Dairy Barn. 1977 Annual Meeting, Canadian Society of Agricultural Sciences, Guelph.
  • Kuczyński T., 1996. Stropowe wloty powietrza w systemie wentylacji budynków inwentarskich w warunkach wysokich temperatur [Ceiling air Inlets in Livestock Building Ventilation at High Outside Temperature]. Zesz. Probl. Postęp. Nauk Rol. 443, 319-326 [in Polish].
  • Kuczyński T. Marszałek H., 1989. Porous Breathing Ceiling Versus Inlets with Recirculating air in Mechanically Ventilated Livestock Buildings. Proceedings of the Eleventh International Congress on Agricultural Engineering. Dodd and Grace (eds). A. A. Balkema, Rotterdam, 1347-1351.
  • Kuczyński T., Marszałek H., Jankowska K., Jodko Z., 1989. Rozwiązania wentylacji podciśnieniowej zastosowane w fermie w Bieganowie [Underpressure Mechanical Ventilation System used at Bieganow Farm]. Trzoda Chlewna 9, 8-11 [in Polish].
  • Liddament M. W., 1996. A Guide to Efficient Ventilation. Air Infiltration an Ventilation Center, University of Warwick, 254 pp.
  • Liddell H., Roalkvam D., McKenzie I., 1996. Pore Ventilation (Sometimes Called Dynamic Insulation). CIBSE/ASHRAE Joint Conference, 18-27.
  • Pattie D. R., 1966. Heat Transmission of Porous Materials in Ventilation. ASAE Transactions 9(3), 409-416.
  • Pattie D. R., 1967. Ventilation of the Animal Barn in Cold Weather. ASAE Paper No. 67-437.
  • Przybyła K., Kuczyński T., 2001. Effect of Dynamic Insulation Ceiling and its Area on Heat Energy Consumption at Nurseries for Early Weaned Piglets. [In:] Livestock Housing Systems. Proceedings of the International Symposium of the C.I.G.R. 2nd Technical Section, Szklarska Poręba, 387-400.
  • Randall J. M., 1975. The Prediction of Airflow Patterns in Livestock Buildings. J. Agric. Egng. Res. 24, 361-374.
  • Sallvik K., 1988. The Influence of Clogging on the Air Penetrability in Porous Materials Used for Air Inlets. Internationales Symposium uber porenlüftung. BAL Gumpenstein, Austria.
  • Sallvik K., Gustafsson G., 1987. Porous Breathing Ceilings in Animal Houses. Theory and Experiences. CIGR Section II. Seminar on Latest Developments in Livestock Housing. Urbana-Champaigne, 156-170.
  • Strom J. S., Zhang G., Morsing S., 1993. Supply Temperatures for Ceiling Inlets Taking Air from An Attic with Un-insulated Roof. Livestock Environment IV. Proc. of the Fifth International Symposium. Coventry, St. Joseph, Michigan, 431-438.
  • Turnbull J. E. Darisse J. P. F., 1975. Ventilation of Dairy Barn With Porous Ceiling Inlet Systems in Animal Houses Part II. Canadian Agric. Eng. 17, 59-62.
  • Turnbull J. E., Hickman J. E., 1974. Ventilation of Dairy Barn with Porous Ceiling Inlet Systems in Animal Houses. Part I. Canadian Agric. Eng. 16, 91-95.
  • Yao W. Z, Christiansen L. L., Muehling A. J., 1986. Air Movement in Neutral Pressure Swine Buildings – Similitude Theory and Test Results. ASAE paper No. 86-4532. St. Joseph, MI.
  • Zhang Y., Barber E. M., Sokhasanj S., 1992. A Model of the Dynamic Thermal Environment in Livestock Buildings. J. Agric Egng. Res. 53, 103-122.
  • Zhang Y. Barber E. M., 1993a. Effects of Control Strategy, Size of Heating/Ventilation Equipment and Controller Time Constant on Thermal Responses and Supplemental Heat Use for a Livestock Building. Proceedings of 4th International Symposium on Livestock Environment. 347-355.
  • Zhang Y., Barber E. M., 1993b. An Evaluation of Heating and Ventilation Strategies for Livestock Buildings. J. Agric. Egng. Res. 60, 217-225.
  • Zhang Y., Barber E. M., 1995. Air Leakage and Ventilation Effectiveness for Confinement Livestock Housing. ASAE Transactions 38(5), 1501-1504.

Typ dokumentu

Bibliografia

Identyfikatory

Identyfikator YADDA

bwmeta1.element.agro-article-c419c46c-9f10-4e42-b182-381f5d8dec7b
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.