PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
2007 | 22 | 2 |

Tytuł artykułu

Application of two sampling methods to assessment to bacteriological contamination of atmospheric air in Olsztyn

Warianty tytułu

PL
Zastosowanie dwoch metod badan w ocenie bakteriologicznego zanieczyszczenia powietrza atmosferycznego Olsztyna

Języki publikacji

EN

Abstrakty

EN
Atmospheric air samples for bacteriological assays were collected by the sedimentation and impaction methods. The samples were used for quantification of psychrotrophic and mesophilous bacteria in atmospheric air in the centre of Olsztyn and in Kortowo, a suburb of the town. It was found that counts of microorganisms were much higher when air was sampled by the sedimentation method rather than the impaction one. Besides, it was demonstrated that the determined groups of bacteria were more numerous in summer (July, August) than in the other months. Higher bacteriological contamination was determined at the three sampling sites in the centre of Olszyn than at the control site in a forest by Kortowskie Lake, in Kortowo.
PL
W próbkach powietrza atmosferycznego – pobranych do badań bakteriologicznych metodami sedymentacyjną i zderzeniową w centrum miasta Olsztyna i dzielnicy Kortowo – oznaczono ilościowo bakterie psychrotrofowe i mezofilne. Stwierdzono kilka razy większą liczebność badanych grup bakterii w próbkach powietrza pobranych metodą sedymentacyjną. Ponadto wykazano, że liczebność oznaczanych grup bakterii była wyższa latem (w lipcu, sierpniu) niż w pozostałych miesiącach badań. Stwierdzono także większe zanieczyszczenie bakteriologiczne powietrza na trzech stanowiskach w centrum Olsztyna niż na stanowisku kontrolnym w lesie, przy Jeziorze Kortowskim, w dzielnicy Kortowo.

Słowa kluczowe

Wydawca

-

Rocznik

Tom

22

Numer

2

Opis fizyczny

p.306-319,fig.,ref.

Twórcy

autor
  • University of Warmia and Mazury in Olsztyn, R.Prawochenskiego 1, 10-719 Olsztyn, Poland
autor

Bibliografia

  • BIESZCZAD S., SOBOTA J. 1993. Zagrożenia, ochrona i kształtowanie środowiska przyrodniczo-rolniczego, Wyd. AR Wrocław.
  • BOVALLIUS A., BUCHT B., ROFFEY R., ANÄS P. 1978. Three-year investigation of the natural airborne bacterial flora at four localities in Sweden. Appl. Environ. Microbiol., 35: 847-852.
  • BOŻKO L., CYPRYK-OSSOWSKA K., KRZYSZTOFIK B. 1961. Mikroflora powietrza zakładów gastronomicznych i powietrza atmosferycznego miasta Warszawy. Acta Microbiol. Pol., 10: 307-322.
  • DI GIORGIO C., KREMPFF A., GUIRAUD H., BINDER P., TIRET C., DUMENIL G. 1996. Atmospheric pollution by airborne microorganisms in the city of Marseilles. Atmos. Environ., 30: 155-160.
  • JUOZAITIS A., LUGAUSKAS A., SVEISTYTE L., ULEVICIUS V., WILLEKE K., GRINSHPUN S. A., REPONEN T. 1998. Assessment of microorganism transfer from the Baltic Sea waters to the atmosphere. J. Aerosol Sci., 29: S547-S548.
  • KRUCZALAK K., OLAŃCZUK-NEYMAN K., MARKS R. 2002. Airborne microorganisms fluctuations over the Gulf of Gdańsk Coastal Zone (Southern Baltic), Pol. J. Environ. Stud., 11: 531-536.
  • KRZYSZTOFIK B. 1992. Mikrobiologia powietrza. Wyd. Politechniki Warszawskiej.
  • LIGHTHART B. 1997. The ecology of bacteria in the alfresco atmosphere. FEMS Microbiology Ecology, 23: 263-274.
  • MANCINELLI R., SHULLS W.A. 1978. Airborne bacteria in an urban environment. Appl. Environ. Microbiol., 35: 1095-1101.
  • MARKS R., KRUCZALAK K., JANKOWSKA K., MICHALSKA M. 2001. Bacteria and fungi in air over the Gulf of Gdańsk and the Baltic Sea. Aerosol Sci., 32: 237 -250.
  • NOWAK A., PRZYBULEWSKA K., TARNOWSKA A. 1998. Badania rozkładu dobowego zanieczyszczenia mikrobiologicznego powietrza na terenie Szczecina. Chem. Inż. Ekol., 5 (1-2): 52-65.
  • Ochrona czystości powietrza. Badania mikrobiologiczne. Postanowienia ogólne i zakres normy. 1989. Polski Komitet Normalizacji, Miar i Jakości, PN-89 Z-04111/0.1
  • Ochrona czystości powietrza. Badania mikrobiologiczne. Oznaczanie liczby bakterii w powietrzu atmosferycznym (imisja) przy pobieraniu próbek metodą aspiracyjną i sedymentacyjną. 1989. Polski Komitet Normalizacji, Miar i Jakości, PN-89 Z-04111/02..
  • Ochrona czystości powietrza. Pobieranie próbek. Pobieranie próbek powietrza atmosferycznego (imisja) do badań mikrobiologicznych metodą aspiracyjną i sedymentacyjną. 1989. Polski Komitet Normalizacji, Miar i Jakości, PN-89 Z-04008/08.
  • RAGA G.B., BAUMGARDNER D., CASTRO T., MARTÏNEZ-ARROYO A., NAVARRO-GONZÄLEZ R. 2001. Mexico city air quality: a qualitative review of gas and aerosol measurements (1960-2000), Atmos. Environ., 35: 4041-4058.
  • SHAFFER B.T., LIGHTHART B. 1997. Survey of culturable airborne bacteria at four diverse locations in Oregon: urban, rural, forest and coastal. Springer-Verlag, New York, 34: 167-177.
  • SCHLEGEL H. G. 2001. Mikrobiologia ogólna. PWN, Warszawa.
  • STANISZ A. 1998. Przystępny kurs statystyki w oparciu o program STATISTICA PL na przykładach z medycyny. StatSoft Polska Sp. z o.o., Kraków, 263-292.
  • TERZIEVA S., DONNELLY J., ULEVICIUS V., GRINSHPUN S.A., WILLEKE K., STELMA G.N., BRENNER K.,P. 1996. Comparison of methods for detection and enumeration of airborne microorganisms collected by liquid impingement. Appl. Environ. Microbiol., 62: 2264-2272.
  • ZMYSŁOWSKA I., JACKOWSKA B. 2003. Microbiological contamination of the air in the centre and recreational areas of the city of Olsztyn. Pol. J. Natur. Sc., 15 (3): 689-700.
  • ZMYSŁOWSKA I., JACKOWSKA B. 2005. The occurrence of the airborne bacteria genus Staphylococcus in the city of Olsztyn. Arch. Environ. Protect., 31 (1): 13-24.

Typ dokumentu

Bibliografia

Identyfikatory

Identyfikator YADDA

bwmeta1.element.agro-article-96a28a91-c939-4cef-b942-a6bff3a79809
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.