The concentration levels of airborne bacteria were measured in clinical/hospital rooms in Upper Silesia, Poland, in buildings of varying conditions. It was found that the typical level of bacterial aerosol concentration is about 10³ CFUm⁻³ in clinical outpatient rooms and ranges from 10² CFUm⁻³ to 10³ CFUm⁻³ in hospitals, depending on the number of occupants and physical quality of the building. The increased level of the airborne bacteria in patient rooms resulting from bed-making was noticed. The Staphylococcus/Micrococcus group was a dominating part of the bacteria in studied hospitals/clinic air, contributing together 58-78% of the total bacteria concentration, confirming that detected airborne bacteria mainly originated from human organisms. The size distributions of bacterial aerosol in naturally ventilated rooms have peaks in the size range between 1.1 and 3.3 μm while in the mechanically ventilated hospital rooms with HVAC the peak appears in the diameter range from 3.3 μm to 4.7 μm.

Wydawca

-

Rocznik

Tom

14

Numer

6

Opis fizyczny

p.883-890,fig.,ref.

Twórcy

  • Medical University of Silesia, School of Public Health, Piekarska 18, 41-902 Bytom, Poland
autor

Bibliografia

  • 1. ISEMAN M. D. A leap of faith. What can we do to curtail intra-institutional transmission of tuberculosis? Annals of Internal Medicine 117, 251, 1992.
  • 2. FOX A., ROSARIO R. M. T. Quantification of muramic acid, a marker for bacterial peptidoglycan, in dust collected from hospital and home air-conditioning conditioning filters using gas chromatography – mass spectrometry. Indoor Air 4, 239, 1994.
  • 3. SARICA S., ASAN A., OTKUN M. T., TURE M. Monitoring indoor airborne fungi and bacteria in the different areas of Trakya University Hospital, Erdine, Turkey. Indoor Built Environment 11, 285, 2002.
  • 4. MALMBERG P. Health effects of organic dust exposure in dairy farmers. American Journal of Industrial Medicine 17, 7, 1990.
  • 5. RYLANDER R. Health effects of cotton dust exposures. American Journal of Industrial Medicine 17, 39, 1990.
  • 6. SIMMONS R. B., PRICE D. L., NOBLE J. A., CROW S. A., AHEARN D. G. Fungal colonization of air filters from hospitals. American Industrial Hygiene Association Journal 58, 900, 1997.
  • 7. MAUS R., GOPPELSSRÖDER A., UMHAUER H. Survival of bacterial and mold spores in air filter media. Atmospheric Environment 35, 105, 2001.
  • 8. FAVERO M. S., PULEO J. R., MARSHALL J. H., OXBORROW G. S. Comparison of microbial contamination levels among hospital operating rooms and industrial clean rooms. Apply Microbiology 16, 480, 1968.
  • 9. NEVALAINEN A. Bacterial Aerosols in Indoor Air, National Public Health Institute, Kuopio, 1989.
  • 10. FLANNIGAN B. Guidelines for evaluation of airborne microbial contamination in buildings. In: Proceedings of International Conference “Fungi and Bacteria in Indoor Air Environments. Health Effects, Detection and Remediation” (E. Johanning, Ch. Yang, eds.), pp 123-129. Eastern New York Occupational Health Program, Saratoga Springs, N. Y., 1994.
  • 11. NEVALAINEN A., PASTUSZKA J., LIEBHABER F., WILLEKE K. Performance of bioaerosol samplers: collection characteristics and sampler design consideration. Atmospheric Environment 26A, 531, 1992.
  • 12. NEVALAINEN A., WILLEKE K., LIEBHABER F., PASTUSZKA J., BURGE H., HENNINGSON E. Bioaerosol sampling. In: Aerosol Measurement: Principles, Techniques and Applications (K. Willeke, P. Baron, eds.), Van Nostrand Reinhold, New York, NY, pp 471-492, 1993.
  • 13. HYVÄRINEN A. M., MARTIKAINEN P. J., NEVALAINEN A. Suitability of poor medium in counting total viable airborne bacteria. Grana 30, 414, 1991.
  • 14. COMMISSION OF THE EUROPEAN COMMUNITIES. Biological Particles in Indoor Environments, Report No. 12, Office for the Official Publications of the European Communities, Luxembourg, 1993.
  • 15. HOLCATOVA I., BENCKO V., BINEK B. Indoor air microbial contamination in the operating theatre and intensive care units of the surgery clinic. In: Proceedings of Indoor Air’93, Vol. 4 (P. Kalliokoski, M. Jantunen, O. Seppänen, eds.), Helsinki, pp 375-378, 1993.
  • 16. KIOSZ D., STOFFREGEN C., SIMON C., von STOCKHAUSEN B. Über den Luftkeimgehalt auf dem Intensivstation einer Kinderklinik. Monatsschr. Kinderheilkd 132, 274, 1984.