PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
2010 | 54 | 2 |

Tytuł artykułu

Analytical pocedure for the determination of lincomycin in honey by liquid chromatography-mass spectrometry

Warianty tytułu

Języki publikacji

EN

Abstrakty

EN
A reliable and sensitive liquid chromatography-electrospray ionisation tandem mass spectrometry analytical method has been developed for the determination of lincomycin in honey samples. After extraction with phosphate buffer by ultrasound, the extracted solution was subjected to the polymeric solid-phase extraction cartridge to remove endogenous compounds. The analysis was carried out on a triple-quadropule tandem mass spectrometer in the multiple reaction monitoring (MRM) mode via electrospray interface operated in positive ionisation modes. The procedure was validated in accordance with the European Commission Decision 2002/657/EC. The mean recovery of the analyte was 80%, with the corresponding intra- and inter-day variation less than 10% and 15%, respectively. Decision limits (CCα) and detection capability (CCß) were 5.60 and 6.11 µg kg⁻¹, respectively.

Wydawca

-

Rocznik

Tom

54

Numer

2

Opis fizyczny

p.205-209,fig.,ref.

Twórcy

autor
  • National Veterinary Research Institute, 24-100 Pulawy, Poland
autor
autor
autor
autor

Bibliografia

  • 1. Adams S.J., Fussell R.J., Dickinson M., Wilkins S., Sharman M.: Study of the depletion of lincomycin residues in honey extracted from treated honeybee (Apis mellifera L.) colonies and the effect of the shook swarm procedure. Anal Chim Acta 2009, 637, 315-320.
  • 2. Anon.: Commission Decision 2002/657/EC of August 2002 implementing Council Directive 96/23/EC concerning the performance of analytical methods and the interpretation of results. O J 2002, L221, 8-36.
  • 3. Benetti C., Piro R., Binato G., Angeletti R., Biancotto G.: Simultaneous determination of lincomycin and five macrolide antibiotic residues in honey by liquid chromatography coupled to electrospray ionization mass spectrometry (LC-MS/MS). Food Add Contamin 2006, 23, 1099-1108.
  • 4. Chiu M.H., Yang H.H., Liu C.H., Zen J.M.: Determination of lincomycin in urine and some foodstuffs by flow injection analysis coupled with liquid chromatography and electrochemical detection with a preanodized screen-printed carbon electrode. J Chromatogr B 2009, 877, 991-994.
  • 5. Sin D.W.M., Ho C., Wong Y.C., Ho S.K., Ip A.C.B.: Simultaneous determination of lincomycin and virginiamycin M1 in swine muscle, liver and kidney by liquid chromatography-electrospray ionization tandem mass spectrometry. Anal Chim Acta 2004, 517, 39-45.
  • 6. Sin D.W.M., Wong Y.U., Ip A.C.B.: Quantitative analysis of lincomycin in animal tissues and bovine milk by liquid chromatography electrospray ionization tandem mass spectrometry. J Pharmac Biomed Anal 2004, 34, 651-659.
  • 7. European Union, Rapid Alert System for Food and Feed (RASFF), http://ec.europa.eu/food/rapidalert/ archive_en.htm, http://ec.europa.eu/food/food/rapidalert/reports
  • 8. Hammel Y.A., Mohamed R., Gremaud E., LeBreton M.H., Guy P.A.: Multi-screening approach to monitor and quantify 42 antibiotic residues in honey by liquid chromatography-tandem mass spectrometry. J Chromatogr A 2008, 1177, 58-76.
  • 9. Lopez M.I., Pettis J.S., Smith I.B., Chu P.S.: Multiclass determination and confirmation of antibiotic residues in honey using LC-MS/MS. J Agric Food Chem 2008, 56, 1553-1559.
  • 10. Regulation (EC) No. 470/2009 of the European Parliament and of the Council of 6 May 2009 laying down community procedures for the establishment of residue limits of pharmacologically active substances in foodstuffs of animal origin, repealing Council Regulation (EEC) No. 2377/90 and amending Directive 2001/82/EC of the European Parliament and of the Council and Regulation (EC) No. 726/2004 of the European Parliament and of the Council.
  • 11. Thompson T.S., Noot D.K., Calvert J., Pernal S.F.: Determination of lincomycin and tylosin residues in honey using solid-phase extraction and liquid chromatography-atmospheric pressure chemical ionization mass spectrometry. J Chromatogr A 2003, 1020, 241-250.

Typ dokumentu

Bibliografia

Identyfikatory

Identyfikator YADDA

bwmeta1.element.agro-article-6cc5b841-b68f-4c6e-8f49-5acfdc91266d
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.