PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Czasopismo

2003 | 62 | 1 |

Tytuł artykułu

An evaluation of the reproducibility of the measurement of the intima-media thickness of carotid arteries

Warianty tytułu

Języki publikacji

EN

Abstrakty

EN
The intima-media thickness (IMT) of carotid arteries was demonstrated to be a reliable measure for early stages of atherosclerosis. B-mode ultrasound may be used to measure carotid IMT. The measurements of the IMT of the carotid artery (CA) conducted by different investigators can be comparable and enable the implementation of clinical trial successfully while maintaining a high reproducibility value. The objective of the study was to evaluate the reproducibility of the measurements made by the same investigator on two separate occasions (intraobserver variability) and the reproducibility of the off-line measurements between four sonographers in our laboratory (interobserver variability). The IMT of CA in 25 subjects (15 post stroke and 10 healthy persons) was investigated with the use of high-resolution ultrasonography. The CA subdivided into the common, bulbs and internal segments were scanned twice with a 3-week interval. Additionally three other readers with different levels of experience and skills in ultrasonography were asked to perform the same measurements in duplicate with at least a 3-week interval between. A high concurrence for intraobserver variability was detected with a correlation coefficient ranging from 0.92 to 0.95; p < 0.0001, and maximal bias 0.019 mm. Interobserver variability for all four readers also demonstrated a high correlation coefficient ranging from 0.72 to 0.83; p < 0.0001, and the maximal bias of measurements did not exceed 0.08 mm. The analogue measurements performed by the team demonstrate a reliable reproducibility in terms of the results of morphologic measurements. The differences obtained in the study were less than the error of the method (i.e. 0.1 mm) and should not influence clinical decision-making. Additionally, this study demonstrated that interobserver concurrence increases with the increasing experience of the investigators.

Wydawca

-

Czasopismo

Rocznik

Tom

62

Numer

1

Opis fizyczny

p.25-31,fig.

Twórcy

autor
  • Karol Marcinkowski University of Medical Sciences, Przybyszewskiego 49, 60-355 Poznan, Poland
autor
autor
autor
autor
autor

Bibliografia

  • 1. Aminbakhsh A, Mancini GBJ (1999) Carotid intimamedia thickness measurements: What defines an abnormality? A systematic review. Clin Invest Med, 22: 149–157.
  • 2. Bahr GF, Bloom G, Friberg U (1957) Volume changes of tissues in physiological fluids during fixation in osmium tetroxide or formaldehyde and during subsequent treatment. Exp Cell Res, 12: 342–343.
  • 3. Baldassarre D, Amato M, Bondioli A, Sirtori CR, Tremoli E (2000) Carotid artery intima-media thickness measured by ultrasonography in normal clinical practice correlates well with atherosclerosis risk factors. Stroke, 31: 2426–2430.
  • 4. Baldassarre D, Tremoli E, Amato M, Veglia F, Bondioli A, Sirtori CR (2000) Reproducibilty validation study comparing analog and digital imaging technologies for the measurement of intima-media thickness. Stroke, 31: 1104–1110.
  • 5. Belcaro G, Barsotti A, Nicolaides AN (1991) “Ultrasonic biopsy” a noninvasive screening technique to evaluate the cardiovascular risk and to follow up the progression and the regression of atherosclerosis. Vasa, 20: 40–50.
  • 6. Berliner JA, Navab M, Fogelman AM, Frank JS, Demer LL, Edwards PA, Watson AD, Lusis AJ (1995) Atherosclerosis: basic mechanisms. oxidation, inflammation and genetics. Circulation, 91: 2488–2496.
  • 7. Bland JM, Altman DJ (1986) Statistical methods for assessing agreement between two methods of clinical measurements. Lancet, 1: 307–310.
  • 8. Bots ML, Hoes AW, Koudstaal PJ, Hofman A, Grobbee DE (1997) Common carotid intima-media thickness and risk of stroke and myocardial infarction. Circulation, 96: 1432–1437.
  • 9. Crouse JR III, Byington RP, Bond GM, Espeland MA, Craven TE, Sprinkle JW, McGovern ME (1995) Provastatin, lipids and atherosclerosis in the carotid arteries (PLAC-II). Am J Cardiol, 75: 455–459.
  • 10. Dwyer JH, Sun P, Kwong-Fu H, Dwyer KM, Selzer RH (1998) Automated intima-media thickness: the Los Angeles Atherosclerosis Study. Ultrasound in Med & Biol, 24: 981–987.
  • 11. Espeland MA, Tang R, Terry JG, Davis DH, Mercuri M, Crouse JR (1999) Associations of risk factors with segment-specific intimal-media thickness of the extracranial carotid artery. Stroke, 30: 1047–1055.
  • 12. Folsom AR, Eckfeld JH, Weitzman S, Ma J, Chambless LE, Barnes RW, Cram KB, Hutchinson RG, for Atherosclerosis Risk in Communities (ARIC) Study Investigation. (1994) Relation of carotid artery wall thickness to diabetes mellitus, fasting glucose and insulin, body size, and physical activity. Stroke, 25: 66–73.
  • 13. Furberg CD, Adams HP, Appelgate WB, Byington RP, Espeland MA, Hartwell T, Hunninghake DB, Lefkowitz DS., Probstifield J, Riley WA, Young B (1994) Effect of Lovastatin on early carotid atherosclerosis and cardiovascular events. Asymptomatic Carotid Artery Progression Study (ACAPS) Research Group. Circulation, 90: 1679–1687.
  • 14. Graf S, Gariepy J, Massonneau M, Armentano RL, Mansour S, Barra JG, Simon A, Levenson J (1999) Experimental and clinical validation of arterial diameter waveform and intimal media thickness obtained from B-mode ultrasound image processing, Ultrasound in Med & Biol, 25: 1353–1363.
  • 15. Grobbee DE, Bots ML (1994) Carotid intima-media thickness as an indicator of generalized atherosclerosis. J Intern Med, 236: 363–370.
  • 16. Hodis HN, Mack WJ, LaBree L (1998) The role of carotid arterial intima-media thickness in predicting clinical coronary events. Ann Intern Med, 128: 262–269.
  • 17. Kanters SDJM, Algra A, van Leeuwen MS, Banga JD (1997) Reproducibility of in vivo carotid intima-media thickness measurement: a review. Stroke, 28: 665–671.
  • 18. Liu ML, Ylialo K, Nuotio I, Salonen R, Salonen JT, Taskinen MR (2002) Association between carotid intimamedia thickness and low-density lipoprotein size and susceptibility of low-density lipoprotein to oxidation in asymptomatic members of familial combined hyperlipidemia families. Stroke, 33: 1255–1260.
  • 19. Lusis AJ (2000) Atherosclerosis. Nature, 407: 233–241.
  • 20. Mac Mahon S, Sharpe N, Gamble G, Hart H, Scott J, Simes J, White H on behalf of the LIPID Trial Research Group (1998) Effects of lowering average or belowaverage cholesterol levels on the progression of carotid atherosclerosis. Circulation, 97: 1784–1790.
  • 21. Mannami T, Konishi M., Baba S, Nishi N, Terao A (1997) Prevalence of asymptomatic carotid atherosclerotic lesions detected by high-resolution ultrasonography and its relations to cardiovascular risk factors in the general population of a Japanese city: the Suita study. Stroke, 28: 518–525.
  • 22. O’Leary DH, Polak JF, Kronmal RA, Kittner SJ, Bond MG, Wolfson SK, Bommer W, Price TR, Gardin JM, Savage PJ (1992) Distribution and correlation of sonographically detected carotid artery disease in the Cardiovascular Health Study. Stroke, 23: 1752–1760.
  • 23. O’Leary DH, Polak JF, Kronmal RA, Manolio TA, Burke GL, Wolfson S.K (1999) Carotid- artery intima and media thickness as a risk factor for myocardial infarction and stroke in older adults. N Engl J Med, 340: 14–22.
  • 24. Perrson J, Formgren J, Israelsson B, Berglund G (1994) Ultrasound-determinated intima-media thickness and atherosclerosis: direct and indirect validation. Arterioscler Thromb, 14: 261–264.
  • 25. Pignoli P, Tremoli E, Poli A, Oreste P, Paoletti R (1986) Intimal plus medial thickness of the arterial wall: a direct measurement with ultrasound imaging. Circulation, 6: 1399–1406.
  • 26. Ross R (1999) Atherosclerosis — an Inflammatory Disease. N Engl J Med, 2: 115–126.
  • 27. Ross R (1993) The pathogenesis of atherosclerosis: a perspective for the 1990s. Nature, 362: 801–809.
  • 28. Schulte-Altedorneburg G, Droste DW, Felszeghy S, Kellermann, Popa V, Hegedus K, Hegedus C, Schmid M, Modis L, Ringelstein EB, Csiba L (2001) Accuracy of in vivo carotid B-mode ultrasound compared with pathological analysis. Stroke, 32: 1520–1524.
  • 29. Toubul JP, Elbaz A, Koller C, Lucas C, Adrai V, Chedru F, Amarenco P (2000) Common carotid artery intima-media thickness and brain infarction. Circulation, 102: 313–318.
  • 30. Touboul PJ, Meairs SP (2001) Carotid artery intima-media thickness. In: Hennerici M, Meairs S (ed.). Cerebrovascular ultrasound: theory, practice and future developments. Cambridge University Press, pp. 152–161.
  • 31. van Swijndregt MAD, De Lange EE, De Groot E, Ackerstaff RGA (1999) An in vivo evaluation of the reproducibility of intima-media thickness measurement of the carotid artery segments using B-mode ultrasound. Ultrasound in Med & Biol, 25: 323–330.
  • 32. Veller MG, Fisher CM, Nicolaides AN, Renton S, Geroulakos G, Stafford NJ, Sarker A, Szendro G, Belcaro G (1993) Measurement of the ultrasonic intimamedia complex in normal subjects. J Vasc Surg, 17: 719–725.
  • 33. Wendelhag I, Liang Q, Gustavsson T, Wikstrand J (1997) A new automated computerized analyzing system simplifies reading and reduces the variability in ultrasound measurement in intima-media thickness. Stroke, 28: 2195–2200.
  • 34. Wong M, Edelstein J, Wollman J, Bond M (1993) Ultrasonic-pathological comparison of the human arterial wall. Verification of intima-media thickness. Arterioscler Thromb, 13: 482–486.
  • 35. Zweibel WJ (1982) High resolution B-mode and duplex carotid sonography. In: Zweibel WJ (ed.). Introduction to vascular sonography. Grune and Stratton, New York, pp. 103–109.

Typ dokumentu

Bibliografia

Identyfikatory

Identyfikator YADDA

bwmeta1.element.agro-article-3e131917-426b-4e1b-a19d-96bd89e46986
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.