Evaluation of portable blood glucose meters using canine and feline pooled blood samples

Treść / Zawartość

Warianty tytułu

Języki publikacji

EN

Abstrakty

EN
This study evaluated the accuracy and reproducibility of a human portable blood glucose meter (PBGM) for canine and feline whole blood. Reference plasma glucose values (RPGV) were concurrently measured using glucose oxidation methods. Fifteen healthy dogs and 6 healthy cats were used for blood sampling. Blood glucose concentrations and hematocrits were adjusted using pooled blood samples for our targeted values. A positive correlation between the PBGM and RPGV was found for both dogs (y = 0.877, x = −24.38, r = 0.9982, n = 73) and cats (y = 1.048, x = −27.06, r = 0.9984, n = 69). Acceptable results were obtained in error grid analysis between PBGM and RPGV in both dogs and cats; 100% of these results were within zones A and B. Following ISO recommendations, a PBGM is considered accurate if 95% of the measurements are within ± 15 mg/dl of the RPGV when the glucose concentration is <100 mg/dl and within ±15% when it is ≥100 mg/dl; however, small numbers of samples were observed inside the acceptable limits for both dogs (11%, 8 of 73 dogs) and cats (39%, 27 of 69 cats). Blood samples with high hematocrits induced lower whole blood glucose values measured by the PBGM than RPGV under hypoglycemic, normoglycemic, and hyperglycemic conditions in both dogs and cats. Therefore, this device is not clinically useful in dogs and cats. New PBGMs which automatically compensate for the hematocrit should be developed in veterinary practice.

Słowa kluczowe

Wydawca

-

Rocznik

Tom

19

Numer

4

Opis fizyczny

p.707-713,fig.,ref.

Twórcy

autor
  • School of Veterinary Nursing and Technology, Faculty of Veterinary Science, Nippon Veterinary and Life Science University, 1-7-1 Kyonancho, Musashino, Tokyo 180-8602, Japan
autor
  • School of Veterinary Nursing and Technology, Faculty of Veterinary Science, Nippon Veterinary and Life Science University, 1-7-1 Kyonancho, Musashino, Tokyo 180-8602, Japan
autor
  • School of Veterinary Nursing and Technology, Faculty of Veterinary Science, Nippon Veterinary and Life Science University, 1-7-1 Kyonancho, Musashino, Tokyo 180-8602, Japan
autor
  • School of Veterinary Nursing and Technology, Faculty of Veterinary Science, Nippon Veterinary and Life Science University, 1-7-1 Kyonancho, Musashino, Tokyo 180-8602, Japan
autor
  • School of Veterinary Nursing and Technology, Faculty of Veterinary Science, Nippon Veterinary and Life Science University, 1-7-1 Kyonancho, Musashino, Tokyo 180-8602, Japan
autor
  • Arkray, Inc. Yousuien-nai, 59 Gansuin-cho, Kamigyo-ku, Kyoto 604-8153, Japan
autor
  • Arkray, Inc. Yousuien-nai, 59 Gansuin-cho, Kamigyo-ku, Kyoto 604-8153, Japan
autor
  • School of Veterinary Nursing and Technology, Faculty of Veterinary Science, Nippon Veterinary and Life Science University, 1-7-1 Kyonancho, Musashino, Tokyo 180-8602, Japan

Bibliografia

  • Barman BN, Ashwood ER, Giddings JC (1993) Separation and size distribution of red blood cells of diverse size, shape, and origin by flow/hyperlayer field-flow fractionation. Anal Biochem 212: 35-42.
  • Brito-Casillas Y, Figueirinhas P, Wiebe JC, López-Rıos L,
  • Pérez-Barreto D, Melián C, Wägner AM (2014) ISO-based assessment of accuracy and precision of glucose meters in dogs. J Vet Intern Med 28: 1405-1413.
  • Clarke WL, Cox D, Gonder-Frederick LA, Carter W, Pohl SL (1987) Evaluating clinical accuracy of systems for self-monitoring of blood glucose. Diabetes Care 10: 622-628.
  • Cox DJ, Gonder-Frederick LA, Kovatchev BP, Julian DM, Clarke WL (1997) Understanding error grid analysis. Diabetes Care 20: 911-912.
  • Domori A, Sunahara A, Tateno M, Miyama TS, Setoguchi A, Endo Y (2014) The clinical utility of two human portable blood glucose meters in canine and feline practice. Vet Clin Pathol 43: 55-62.
  • Freckmann G, Schmid C, Baumstark A, Pleus S, Link M, Haug C (2012) System accuracy evaluation of 43 blood glucose monitoring systems for self-monitoring of blood glucose according to DIN EN ISO 15197. J Diabetes Sci Technol 6: 1060-1075.
  • Higgins PJ, Garlick RL, Bunn HF (1982) Glycosylated hemoglobin in human and animal red cells. Role of glucose permeability. Diabetes 31: 743-748.
  • ISO 15197 (2003) In Vitro Diagnostic Test Systems-Requirements for Blood-glucose Monitoring Systems for Self-testing in Managing Diabetes Mellitus. European Committee for Standardization (CEN): Brussels, http://www.iso.org/iso/catalogue–detail?csnumber=26309
  • ISO 15197 (2013) In Vitro Diagnostic Test Systems-Requirements for Blood-glucose Monitoring Systems for Self-testing in Managing Diabetes Mellitus. European Committee for Standardization (CEN): Brussels, http://www.iso.org/iso/catalogue–detail?csnumber=54976
  • Johnson BM, Fry MM, Flatland B, Kirk CA (2009) Comparison of a human portable blood glucose meter, veterinary portable blood glucose meter, and automated chemistry analyzer for measurement of blood glucose concentrations in dogs. J Am Vet Med Assoc 235: 1309-1313.
  • Khositseth A, Pharadornuwat O, Lertbunrian R, Anantasit N, Vaewpanich J (2015) Accuracy of bedside glucometry in critically ill children with peripheral hypoperfusion. J Clin Monit Comput 29: 145-152.
  • Mori A, Lee P, Yokoyama T, Oda H, Saeki K, Miki Y, Nozawa S, Azakami D, Momota Y, Makino Y, Matsubara T, Osaka M, Ishioka K, Arai T, Sako T (2011) Evaluation of artificial pancreas technology for continuous blood glucose monitoring in dogs. J Artif Organs 14: 133-139.
  • Magnani M, Dachg M, Bossw M, Fornaini G (1978) Comparative studies on red blood cell glucose phosphorylating activities of mammals. Comp Biochem Physiol B 60: 323-327.
  • Rendell M, Stephen PM, Paulsen R, Valentine JL, Rasbold K, Hestorff T, Eastberg S, Shint DC (1985) An interspecies comparison of normal levels of glycosylated hemoglobin and glycosylated albumin. Comp Biochem Physiol B 81: 819-822.
  • Sacks DB (2006) Carbohydrates. pp. 837-901. In: Tietz Textbook of Clinical Chemistry and Molecular Diagnostics. 4th ed. (Burtis CA, Ashwood ER, Bruns DE, eds.), Elsevier Saunders, St. Louis, MO.
  • Wess G, Reusch C (2000a) Assessment of five portable blood glucose meters for use in cats. Am J Vet Res 61: 1587-1592.
  • Wess G, Reusch C (2000b) Capillary blood sampling from the ear of dogs and cats and use of portable meters to measure glucose concentration. J Small Anim Pract 41: 60-66.

Typ dokumentu

Bibliografia

Identyfikatory

Identyfikator YADDA

bwmeta1.element.agro-a99f2071-6b11-45f5-9f63-163a774b2779
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.