PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
2012 | 56 | 2 |

Tytuł artykułu

Usefulness of serum cystatin C measurement for assessing renal function in cats

Warianty tytułu

Języki publikacji

EN

Abstrakty

EN
The aim of the work was to determine the concentration of serum cystatin C and usability of its measurement in diagnostics of renal failure in cats. The reference point was the value of glomerular filtration rate (GFR), calculated on the basis of plasma clearance of iohexol (Pcio). Seventy cats were divided into two groups: group I - 24 healthy cats, group II - 46 cats affected with renal dysfunction. The measurement of serum cystatin C was done according to immunonefelometric method. In order to estimate Pcio, the following blood samples were collected: pre-sample -0, and samples collected 120, 180, 240, and 300 min after intravenous administration of iohexol. Its concentration was determined using high performance liquid chromatography. Pcio was obtained using a one-compartment model, according to the method developed by Krutzen Back and Nilsson-Ehl. Serum concentration of cystatin C in cats with renal dysfunction was significantly statistically higher (1.3 ± 0.6 mg/L) as compared to the group of healthy animals (0.7 ± 0.2 mg/L). Statistical analysis of the data confirmed strong correlation between GFR and serum concentration of cystatin C (r = - 0.51). Data analysis on the basis of the receiver operating characteristic curve proved that cystatin C seems to be more reliable parameter than creatinine in the assessment of kidneys function in cats and the measurement of cystatin C in blood serum can be of a considerable meaning as far as early diagnosis of renal failure in cats is concerned.

Słowa kluczowe

Wydawca

-

Rocznik

Tom

56

Numer

2

Opis fizyczny

p.235-239,fig.,ref.

Twórcy

  • Department of Internal Diseases with Clinic for Horses, Dogs and Cats, Faculty of Veterinary Medicine, University of Environmental and Life Sciences, 50-322 Wroclaw, Poland

Bibliografia

  • 1. Almy F.S., Christopher M.M., King D.P., Brown S.A.: Evaluation of cystatin C as a endogenous marker of glomerular filtration rate in dogs. J Vet Intern Med 2002, 16, 45-51.
  • 2. Antognoni M.T., Siepi D., Porciello F., Fruganti G.: Use of serum cystatin C determination as a marker of renal function in the dog. Vet Res Commun 2005, 29, 265- 267.
  • 3. Bokenkamp A., Ciarimboli G., Dieterich C.: Cystatin C in a rat model of end-stage renal failure. Ren Fail 2001, 23, 431-438.
  • 4. Brochner-Mortensen J.: A simple method for the determination of glomerular filtration rate. Scand J Clin Lab Invest 1982, 30, 271-274.
  • 5. Brown S.A., Finco D.R., Boudinot F.D., Wright J., Taver S.L., Cooper T.: Evaluation of a single injection method, using iohexol, for estimating glomerular filtration rate in cats and dogs. Am J Vet Res 1996, 57, 105-110.
  • 6. Colle A., Tavera C., Laurent P., Leung-Tack J., Girolami J.P.: Direct radioimmunoassay of rat cystatin C: increased urinary excretion of this cysteine proteases inhibitor during chromate nephropathy. J Immunoassay 1990, 11, 199-214.
  • 7. Elliott J., Grauer G.F.: Canine and Feline Nephrology and Urology. Edited by BSAVA Gloucester 2007, pp. 117-126.
  • 8. Gleadhill A., Michell A.R.: Evaluation of Iohexol as a marker for the clinical measurement of glomerular filtration rate in dogs. Res Vet Sci 1996, 60, 117-121.
  • 9. Goy-Thollot I., Chafotte C., Besse S., Garnier F., Barthez P.: Iohexol plasma clearance in healthy dogs and cats. Vet Radiol Ultrasound 2006, 47, 168-173.
  • 10. Herget-Rosenthal S., Bokenkamp A., Hofmann W.: How to estimate GFR-serum creatinine, serum cystatin C or equations? Clin Biochem 2007, 40, 153-161.
  • 11. Heine R.: The laboratory diagnosis of feline kidney disease (in Polish) Vet Focus 2008, 2, 16-22.
  • 12. Imiela J., Lewandowicz A.: Cystatin C in the diagnosis of chronic kidney disease. Nefrol Dial Pol 2007, 11, 126- 132.
  • 13. Jonkisz P., Kungl K., Sikorska A., Kurosad A., Nicpoń J.: Cystatin C analysis in the dog - a comparison of turbidimetric and nephelometric assay results. Acta Vet Hung 2010, 58, 59-67.
  • 14. Krutzen E., Back S., Nilsson-Ehle P., Nilsson-Ehle I.: Plasma clearance of a new contrast agent, iohexol: a method for the assessment of glomerular filtration rate. J Lab Clin Med 1984, 104, 955-961.
  • 15. Le Garreres A., Laroute V., De La Farge F., Boudet K.G., Lefebvre H.P.: Disposition of plasma creatinine in non-azotaemic and moderately azotaemic cats. J Fel Med Surg 2007, 9, 89-96.
  • 16. Marchewka Z.: Low molecular weight biomarkers in the nephrotoxicity. Adv Clin Exp Med 2006, 15, 1129-1138.
  • 17. Martin C., Pechereau D., de la Farge F., Braun J.P.: Cystatine C plasmatique ches le chatles techniques actuelles ne permettent pas de l'utiliser comme marqueur d'insuffisance renale. Rev Med Vet 2002, 153, 305-310.
  • 18. Matuszkiewicz-Rowińska J.: Acute kidney injury and RIFLE classification of advantages and disadvantages. Nefrol Dial Pol 2008, 12, 248-250.
  • 19. Miyamoto K.; Clinical application of plasma clearance of iohexol on feline patients. J Fel Med Surg 2001, 3, 143-147.
  • 20. Miyamoto K.: Use of plasma clearance of iohexol for estimating glomerular filtration rate in cats. Am J Vet Res 2001, 62, 572-575.
  • 21. Newman D.J., Thakkar H., Edwards R.G., Wilkie M., White T., Grubb A.O., Price C.P.: Serum cystatin C measured by automated immunoassay: A more sensitive marker of changes in GFR than serum creatinine. Kidney Int 1995, 47, 312-318.
  • 22. Obrenović R., Petrović D., Majkić-Singh N., Trbojević J., Stojimirović B.: Influence of proteinuria on cystatin C serum concentration in patients with priman, gromerulonephritis. Jugoslov Med Biochem 2006, 25, 21-25.
  • 23. Plotnick A.: Feline chronic renal failure: long-term medical management, cp.vetlearn.com, Compendium Yardley PA 2007.
  • 24. Sulicka J., Franczuk P., Rewiuk K.: Clinical usefulness of cystatin c as a marker of renal failure in the elderly. Gerontol Pol 2005, 13, 84-87.
  • 25. Tamba K., Kusano E., Ando Y., Asano Y.: Prospective evaluation of renal function by serum cystatin-C: comparison with three other parameters of glomerular filtration rate. Nihon Jinzo Gakkai Shi 2001, 43, 646- 650.
  • 26. Trof R.J., Di Maggio F., Leemreis J., Groeneveld A.B.: Biomarkers of acute renal injury and renal failure. Shock 2006, 26, 245-53.
  • 27. van Hoek I., Vandermeulen E., Duchateau L.: Comparison and reproducibility of plasma clearance of exogenous creatinine, exo-iohexol, endo-iohexol, and 51 Cr-EDTA in young adult and aged healthy cats. J Vet Int Med 2007, 21, 950-958.
  • 28. Wehner A., Hartmann K., Hirschberger J.: Utility of serum cystatin C as a clinical measure of renal function in dogs. J Am Anim Hosp Assoc 2008, 44, 131-138.
  • 29. Winnicka A.: Reference values of basic laboratory examinations in veterinary medicine. Edited by SGGW, Warsaw, 1997.

Typ dokumentu

Bibliografia

Identyfikatory

Identyfikator YADDA

bwmeta1.element.agro-949c5ee7-299f-42b0-a698-befe4d588f1d
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.