Detailed radiological study of the patent ductus arteriosus: a computed tomography study in the Polish population

Warianty tytułu

Języki publikacji

EN

Abstrakty

Background: The aim of the study was to perform qualitative and quantitative computed tomography (CT) angiography-based evaluation of patent ductus arteriosus (PDA) morphology and its influence on morphology of the great vessels. Materials and methods: Two-thousand twenty-two patients underwent 64-slice or dual-source CT and were retrospectively screened for the presence of PDA. Those who had presence of PDA underwent evaluation of its anatomy and morphology. Results: Thirty-two adult patients with PDA were evaluated (mean age 41.4 ± 17.4 years). Subjects with PDA had a higher value of aortic isthmus (p = 0.0148), main pulmonary artery (p < 0.0001), right (p =0.0007) and left (p = 0.0074) pulmonary arteries diameters than individuals from control group (16 adults, median age 43.3 ± 12.4 years). Types A, B, C, D, and E of PDA morphology occurred in 16 (50%), 3 (9%), 9 (28%), 2 (6%), and 2 (6%) patients, respectively. Subjects with the type A configuration of PDA tended to have a larger diameter at the aortic orifice (10.2 ± 5.2 mm vs. 6.4 ± 4.9 mm, p = 0.09) and a larger maximal diameter (10.3 ± 5.3 mm vs. 7.1 ± 4.7 mm, p = 0.14) compared to subjects with the type C configuration. The values of minimal, mean, and maximal diameters of PDA were 4.7 ± 1.9 mm, 7.0 ± 3.2 mm, and 9.4 ± 5.0 mm, respectively. The Spearman correlation coefficient between the main pulmonary artery and PDA diameters demonstrated a good correlation for minimal (r = 0.70, p < 0.001), mean (r = 0.62, p = 001), and maximal (r = 0.60, p = 0.0003) PDA diameters. Conclusions: Computed tomography enables quantitative and qualitative evaluation of PDA, including its type of morphology, length, and diameters. In the evaluated adult population with PDA, the majority of patients had dilation of the aortic isthmus and pulmonary arteries. PDA diameters correlate with diameters of the pulmonary arteries and this correlation is strongest between PDA diameter at the narrowest site and main pulmonary artery. (Folia Morphol 2020; 79, 3: 462–468)

Słowa kluczowe

Wydawca

-

Czasopismo

Rocznik

Tom

79

Numer

3

Opis fizyczny

p.462-468,fig.,ref.

Twórcy

autor
  • Department of Radiology and Diagnostic Imaging, John Paul II Hospital, Krakow, Poland
autor
  • Department of Radiology and Diagnostic Imaging, John Paul II Hospital, Krakow, Poland
autor
  • Department of Radiology and Diagnostic Imaging, John Paul II Hospital, Krakow, Poland
autor
  • Department of Radiology and Diagnostic Imaging, John Paul II Hospital, Krakow, Poland
autor
  • Department of Anatomy, Jagiellonian University Medical College, Krakow, Poland
  • Department of Radiology and Diagnostic Imaging, John Paul II Hospital, Krakow, Poland

Bibliografia

  • 1. Backer CL, Mavroudis C. Congenital heart surgery nomenclature and database project: patent ductus arteriosus, coarctation of the aorta, interrupted aortic arch. Ann Thorac Surg. 2000; 69(4 Suppl): S298–S307, doi: 10.1016/s0003-4975(99)01280-1, indexed in Pubmed: 10798436.
  • 2. Beerbaum P, Körperich H, Barth P, et al. Noninvasive quantification of left-to-right shunt in pediatric patients: phase-contrast cine magnetic resonance imaging compared with invasive oximetry. Circulation. 2001; 103(20): 2476–2482, doi: 10.1161/01.cir.103.20.2476, indexed in Pubmed: 11369688.
  • 3. Carlgren LE. The incidence of congenital heart disease in children born in Gothenburg 1941-1950. Br Heart J. 1959; 21(1): 40–50, doi: 10.1136/hrt.21.1.40, indexed in Pubmed: 13618461.
  • 4. El Hajjar M, Vaksmann G, Rakza T, et al. Severity of the ductal shunt: a comparison of different markers. Arch Dis Child Fetal Neonatal Ed. 2005; 90(5): F419–F422, doi: 10.1136/adc.2003.027698, indexed in Pubmed: 16113155.
  • 5. Espino-Vela J, Cardenas N, Cruz R. Patent ductus arteriosus. With special reference to patients with pulmonary hypertension. Circulation. 1968; 38(1 Suppl): 45–60, doi: 10.1161/01.cir.38.1s5.v-45, indexed in Pubmed: 5712383.
  • 6. Evans N, Iyer P. Assessment of ductus arteriosus shunt in preterm infants supported by mechanical ventilation: effect of interatrial shunting. J Pediatr. 1994; 125(5 Pt 1): 778–785, doi: 10.1016/s0022-3476(94)70078-8, indexed in Pubmed: 7965434.
  • 7. Forsey JT, Elmasry OA, Martin RP. Patent arterial duct. Orphanet J Rare Dis. 2009; 4: 17, doi: 10.1186/1750-1172-4-17, indexed in Pubmed: 19591690.
  • 8. Goitein O, Fuhrman CR, Lacomis JM. Incidental finding on MDCT of patent ductus arteriosus: use of CT and MRI to assess clinical importance. Am J Roentgenol. 2005; 184(6): 1924–1931, doi: 10.2214/ajr.184.6.01841924, indexed in Pubmed: 15908555.
  • 9. Kim JH, Baek JH. Thoracic endovascular repair technique for the treatment of patent ductus arteriosus in an elderly patient: A case report. Medicine (Baltimore). 2018; 97(49): e13558, doi: 10.1097/MD.0000000000013558, indexed in Pubmed: 30544472.
  • 10. Kimura-Hayama ET, Meléndez G, Mendizábal AL, et al. Uncommon congenital and acquired aortic diseases: role of multidetector CT angiography. Radiographics. 2010; 30(1): 79–98, doi: 10.1148/rg.301095061, indexed in Pubmed: 20083587.
  • 11. Krichenko A, Benson LN, Burrows P, et al. Angiographic classification of the isolated, persistently patent ductus arteriosus and implications for percutaneous catheter occlusion. Am J Cardiol. 1989; 63(12): 877–880, doi: 10.1016/0002-9149(89)90064-7, indexed in Pubmed: 2929450.
  • 12. Mitchell SC, Korones SB, Berendes HW. Congenital heart disease in 56,109 births. Incidence and natural history. Circulation. 1971; 43(3): 323–332, doi: 10.1161/01.cir.43.3.323, indexed in Pubmed: 5102136.
  • 13. Pelberg R, Mazur W. Vascular CT angiography manual. Springer-Verlag, London 2003.
  • 14. Schneider D, Moore J. Patent ductus arteriosus. Circulation. 2006; 114(17): 1873–1882, doi: 10.1161/circulationaha.105.592063.
  • 15. Shimada S, Kasai T, Konishi M, et al. Effects of patent ductus arteriosus on left ventricular output and organ blood flows in preterm infants with respiratory distress syndrome treated with surfactant. J Pediatr. 1994; 125(2): 270–277, doi: 10.1016/s0022-3476(94)70210-1, indexed in Pubmed: 8040777.
  • 16. Stout KK, Daniels CJ, Aboulhosn JA, et al. 2018 AHA/ACC Guideline for the Management of Adults With Congenital Heart Disease: Executive Summary: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines. Circulation. 2019; 139(14): e637–e697, doi: 10.1161/CIR.0000000000000602, indexed in Pubmed: 30586768.
  • 17. Suzmura H, Nitta A, Tanaka O. Diastolic flow velocity of left pulmonary artery of patent ductus arteriosus in preterm infants. Pediatr Int. 2001; 43: 146–151.
  • 18. Waller BF. Morphological aspects of valvular heart disease: Part I. Curr Probl Cardiol. 1984; 9(7): 1–66, indexed in Pubmed: 6488868.
  • 19. Walther FJ, Kim DH, Ebrahimi M, et al. Pulsed Doppler measurement of left ventricular output as early predictor of symptomatic patent ductus arteriosus in very preterm infants. Biol Neonate. 1989; 56(3): 121–128, doi: 10.1159/000243112, indexed in Pubmed: 2804176.

Typ dokumentu

Bibliografia

Identyfikatory

Identyfikator YADDA

bwmeta1.element.agro-92cd5c36-725b-45f3-a341-c83edc96a205
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.