PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
2014 | 70 | 03 |

Tytuł artykułu

Zastosowanie metody amplifikacji w warunkach stałej temperatury (LAMP) do wykrywania wirusa zapalenia jelit kaczek

Autorzy

Warianty tytułu

EN
Application of loop-mediated isothermal amplification (LAMP) for the detection of duck enteritis virus

Języki publikacji

PL

Abstrakty

EN
Duck plague (DP) caused by duck enteritis virus (DEV) is an acute infection of waterfowl. Apart from geese and ducks free-ranging swans are susceptible to infection. The exact epidemiological situation in relation to DEV infection in Eastern Europe is unknown. Therefore it was reasonable to conduct a study on DEV occurrence using the modern but simple loop-mediated isothermal amplification (LAMP). The use of LAMP facilitated DEV DNA detection in a time below 30 min. The method was also specific solely for DEV, while its detection limit was 1 pg of DNA. The aim of this study was the optimization of LAMP for detection of DEV infections among free-ranging water birds. The presence of DEV DNA was identified in 96 birds (72.7%), predominantly in wild ducks (Anas platyrhynchos) and mute swans (Cygnus olor). The results were recorded in visible light as a green color of reaction mixtures and their fluorescence under ultraviolet light. The presented study indicates the usefulness of the developed LAMP technique for DEV detection and the high percentage of free-ranging water birds infected with this virus. The study will be continued in the future for the determination of DEV occurrence in domestic geese and ducks.

Wydawca

-

Rocznik

Tom

70

Numer

03

Opis fizyczny

s.169-171,fot.,bibliogr.

Twórcy

  • Zakład Chorób Wirusowych Drobiu, Państwowy Instytut Weterynaryjny - Państwowy Instytut Badawczy, Al.Partyzantów 57, 24-100 Puławy

Bibliografia

  • 1. Gough R. E., Alexander D. J.: Duck virus enteritis in Great Britain, 1980 to 1989. Vet. Rec. 1990, 126, 595-597.
  • 2. Hansen W. R., Brown S. E., Nashold S. W., Knudson D. L.: Identification of duck plague virus by polymerase chain reaction. Avian Dis. 1999, 43, 106-115.
  • 3. Ji J., Du L. Q., Xie Q. M., Cao Y. C., Zuo K. J., Xue C. Y., Ma J. Y., Chen F., Bee Y. Z.: Rapid diagnosis of duck plagues virus infection by loop-mediated isothermal amplification. Res. Vet. Sci. 2009, 87, 53-58.
  • 4. Kaleta E. F.: Herpesviruses of birds. Avian Pathol. 1990, 19, 193-211.
  • 5. Kumar N. V., Reddy Y. N., Rao M. V. S.: Enzyme linked immunosorbent assay for detection of duck plague virus. J. Ind. Vet. 2004, 5, 481-483.
  • 6. Leibovitz L.: Progress report: duck plague surveillance of American Anseriformes. Wildl. Dis. 1968, 4, 87-91.
  • 7. Parida M., Posadas G., Inoue S., Hasebe F., Morita K.: Real-Time reverse transcription loop-mediated isothermal amplification for rapid detection of West Nile Virus. J. Clin. Microbiol. 2004, 42, 257-263.
  • 8. Plummer P. J., Alefantis T., Kaplan S., O’Connell P., Shawky S., Schat K. A.: Detection of duck enteritis virus by polymerase chain reaction. Avian Dis. 1998, 42, 554-564.
  • 9. Qi X., Yang X., Cheng A., Wang M., Zhu D., Jia R.: Quantitative analysis of virulent duck enteritis virus loads in experimentally infected ducklings. Avian Dis. 2008, 52, 338-344.
  • 10. Song C., Wan H., Yu S., Han X., Qiu X., Hu Q., Tan L., Ding C.: Rapid detection of duck hepatitis virus type-1 by reverse transcription loop-mediated isothermal amplification. J. Virol. Methods 2012, 182, 76-81.
  • 11. Tarasiuk K., Woźniakowski G., Samorek-Salamonowicz E.: Loop-mediated isothermal amplification as a simple molecular method for the detection of Derzsy’s disease virus. Bull. Vet. Inst. Pulawy 2013, 57, 19-23.
  • 12. Wobeser G.: Experimental duck plague in blue-winged teal and Canada geese. J. Wildl. Dis. 1987, 23, 368-375.
  • 13. Woźniakowski G., Kozdruń W., Samorek-Salamonowicz E.: Loop-mediated isothermal amplification for the detection of goose circovirus. Virol J. 9, 110. DOI:10.1186/1743-422X-9-110.
  • 14. Woźniakowski G., Samorek-Salamonowicz E., Kozdruń W.: Comparison of loop-mediated isothermal amplification (LAMP) and polymerase chain reaction (PCR) for the detection and differentiation of Marek’s disease virus serotype 1,2 and 3. Avian Dis. 2013, 57, 539-543.
  • 15. Yang L., Li J., Bi Y., Xu L., Liu W.: Development and application of a reverse transcription loop-mediated isothermal amplification method for rapid detection of duck hepatitis A virus type 1. Virus Genes 2012, 45, 585-589.
  • 16. Yang J. L., Rui Y., Cheng A. C., Wang M. S., Fu L. Z., Yang S. Q., Zhang S. H., Yang L., Xu Z. Y.: A simple and rapid method for detection of Goose Parvovirus in the field by loop mediated isothermal amplification. Virol. J. 2010, 7, 14. DOI: 10.1186/1743-422X-7-14.
  • 17. Yoshida H., Sakoda Y., Endo M., Motoshima M., Yoshino F., Yamamoto N., Okamatsu M., Soejima T., Senba S., Kanda H., Kida H.: Evaluation of the reverse transcription loop-mediated isothermal amplification (RT-LAMP) as a screening method for the detection of influenza viruses in the fecal materials of water birds. J. Vet. Med. Sci. 2011, 73, 753-758.

Typ dokumentu

Bibliografia

Identyfikatory

Identyfikator YADDA

bwmeta1.element.agro-669f9e6d-5263-49c4-bef5-ce8fcc067d9a
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.