Tytuł artykułu

Increasing of sensitivity of relay protection from earth fault of phase in networks 6-10 KV with insulated neutral

Warianty tytułu

RU
Povyshenie chuvstvitel'nosti relejnoj zashhity ot zamykanij fazy na zemlju v setjakh s izolirovannoj nejtral'ju

Języki publikacji

EN

Abstrakty

EN
RU

Wydawca

-

Rocznik

Tom

10D

Opis fizyczny

p.51-57,fig.,ref.

Twórcy

  • Volodymyr Dahl East-Ukrainian University, Lugansk, Ukraine
autor
autor

Bibliografia

  • 1. Andreev V.A., 2006.: Relay protection and automation of the systems of power supply. Moscow, Higher school, 639 p.
  • 2. Bazilevich M.B., Sabadash I.O., 2000.: Protecting from earth faults in a network with isolated neutral. Coll, scien. papers DonDTU, Series: Electrical and power engineering, Donetsk, DonDTU, No 21, p. 93-96.
  • 3. Borukhman V.A., 2000.: About exploitation of selective protection from an earth fault in networks 6-10 kV. Measures on their improvement. Power engineering, N° 1. p. 20-21.
  • 4. Dudarev L.E., Thubkov V.V., 1978.: Some features of transients at the earth fault of phase in networks 6-35 kV and the use them for devices of relay protection. Electric power station, No 6, p. 68-71.
  • 5. Gusenkov A.V., 2005.: Determination of errors of cable transformers of current of a zero sequence. Herald of scientifically-industrial society. Moscow, No 9, p. 28-37.
  • 6. Il'enko O.C., Nail V.M., Santockiy V.G., at alias, 1977.: About expedience of the automatic bridging of the damaged phase in air networks 10 kV. Power engineering and electrification, No 4, p. 4-5.
  • 7. Krasyanskiy V.M., Bondarenko L.G., Feschenko P.P., Saptockiy V.G., 1997.: Automatic bridging of phase in electric networks of 6 - 10 kV with isolated neutral - Method of the centralized improvement of safety. Power engineering and electrification. No 6. p. 39-41.
  • 8. Kuz'menko D.I., 2007.: Review of existent protection from monophase earth faults in networks 6-10 kv with neutral, earthed through a arc-suppressing reactor Coll, scien. papers DonDTU, Series: Electrical and power engineering, Donetsk, DonDTU, issue 7 (128). - p. 197-202.
  • 9. Plashchinskiy L., Zhidkov V.O., Ilin Y.N., 1982.: Increase of effectiveness of the protective bridging in mine networks by voltage 6-10 kV. Coal. No 3. p. 52-54.
  • 10. Popov I. N., Lachugin V.F., Sokolov G.V. 1986.: Relay protection, based on control of transients. Moscow, Energoizdat, 248 p.
  • 11. Shabad M.A., 1999.: Review of the modes of grounding of neutral and protections from earth fault in networks 6-35 kV in Russia. Power engineering, No 2, p. 11-13.
  • 12. Shabad M.A., 2003.: Calculations of relay protection and automation of distributive networks. SPb., PEIPK. 350 p.
  • 13. Shalin A., Dikhterev A., 2008.: Cable transformers of current. Methods of improvement of sensitivity. Electrical news. IPK "NP PRINT", St. Petersburg. - N° 6(48). - p. 28-32.
  • 14. Shalin A.I., 2005.: Earth faults in the networks of 6-35 kv. Cases of incorrect works of protections. Electrical news, Ns 2(32), p. 58-61.
  • 15. Shalin A.I., Khabarov A.M., 2006.: Earth faults in the networks of 6-35 kV. Not balances. Electrical news, No 3(39), p. 51-54.; No 4(40). p. 49-52.; No 5(41), p. 57-60.
  • 16. Shchutskiy V.I., Zhidkov V.O., Ilin Y.N., 1986.: Protective bridging of monophase damages of electrical installation. Moscow, Energoizdat, 152 p.
  • 17. Vaynshteyn R.A., Golovko S.I., Grigorov V.S., 1998.: Protecting from earth faults in the compensated networks 6-10 kV. Electric power station, No 7, p. 26-30.

Typ dokumentu

Bibliografia

Identyfikatory

Identyfikator YADDA

bwmeta1.element.agro-24a45ac3-c0b8-4cb7-9607-aeef89dad34c
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.