PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
2015 | 22 | 3 |

Tytuł artykułu

Study of harmonic detection methods under non-ideal conditions in ship power network

Warianty tytułu

Języki publikacji

EN

Abstrakty

EN
An improved harmonic detection method based on average arithmetic is proposed. According to the research results, the designed solution uses an LPF (low-pass-filter) and a mean value module connected in series instead of the conventional mean value module, and simultaneously, a three-phase voltage phase-locked module instead of commonly used PLL (phase lock loop) module is applied in order to reduce the influence caused by three-phase distorted voltage and rapid variation of load. The experimental results show that the application of this solution leads to increase in the accuracy of harmonics detection for distorted three-phase voltage and rapid variation of load

Słowa kluczowe

Wydawca

-

Rocznik

Tom

22

Numer

3

Opis fizyczny

p.82-89,fig.,ref.

Twórcy

autor
  • Logistics Engineering Faculty, Shanghai Maritime University, Shanghai 201306, China
  • Marine Electrical Engineering Faculty, Gdynia Maritime University, Morska 81-87, 81-225 Gdynia, Poland
autor
  • Marine Electrical Engineering Faculty, Gdynia Maritime University, Morska 81-87, 81-225 Gdynia, Poland
autor
  • Logistics Engineering Faculty, Shanghai Maritime University, Shanghai 201306, China

Bibliografia

  • 1. Akagi H., Kanazawa Y., Nabae A., Instantaneous reactive power compensators comprising switching devices without energy storage components, IEEE Transactions on Industry Application 20 (3) (1984) 625-630
  • 2. Ding Ju-Xia, Zhang Xiu-Feng. A harmonics-detection method without PLL and based on average theory in single-phase circuit [J]. Power System Protection and Control, 2010, 38(13): 26-30
  • 3. Dong Tian-Bing, Cheng Han-Xiang, He Man-run. Time delay analyzing and the setting about the frequency compensation of active power Filter [J]. Electric Drive, 2011, 41(2): 24-27
  • 4. EN Standard 50160. Voltage characteristics of electricity supplied by public distribution systems
  • 5. IEC 61000-4-7:2007 General Guide on Harmonics and Interharmonics Measurements for Power Supply Systems and Equipment Connected Thereto
  • 6. Jiang You-Hua, Cao Yi-long, Tang Zhong. Design and application of active power filter based on average arithmetic [J]. Power Electronics, 2010, 44(2): 42-43
  • 7. Lu Zhen, Liang Guo-Lu, Lu Yu. Improved ip-iq harmonic detection method and simulation [J]. Power Electronics, 2012, 46(5): 81-83
  • 8. Meng Jun-Xia, Zhou Zi-Guan, Li Guang-Hui. Detection of Distorted Current Based on ip-iq Method and Its Physical Realization [J]. Power System Technology, 2012, 36(5): 125-131
  • 9. Mindykowski J., Xu X., Tarasiuk T., A new concept of harmonic current detection for shunt active power filters control, Measurement 46 (2013) 4334-4341
  • 10. Report of the investigation of the catastrophic failure of a capacitor in the aft harmonic filter room on board RMS Queen Mary 2 while approaching Barcelona on 23 September 2010, Marine Accident Investigation Branch, December, 2011
  • 11. Tarasiuk T., Mindykowski J., An extended interpretation of THD concept in the wake of ship electric power system research, Measurement 45 (2012), 207-212
  • 12. Tu Yong-Chang, Liu Jian-Gong, Wang Wei. Research on improved algorithm for harmonic current detection based on instantaneous reactive power theory [J]. Modern Electronics Technique, 2013, 36(3): 145-147
  • 13. Wang Yi-Fei, Li Yun-Wei. Three-Phase Cascaded Delayed Signal Cancellation PLL for Fast Selective Harmonic Detection [J]. IEEE Transactions on industrial electronics, 2013, 60(4): 1452-1463
  • 14. Xie Dong, Hui Jing. Application and research on modified ip-iq harmonic detection method [J]. Power Electronics, 2013, 47(1): 95-97
  • 15. Xu X, Mindykowski J., Chen P., Study on Hybrid Filtering Solution for Marine Electric Network, Polish Maritime Research 2 (65) 2010. vol.17, pp.72-78
  • 16. Yang Sheng-Yue, Wu Min, Huang Shen-Xi. A harmonic current detection method considering frequency shift [J]. Automation of Electric Power Systems, 2012, 36(7): 57-61
  • 17. Yuan Xu-Feng, Cheng Shi-Jie, Wen Jin-Wu. An improved method of instantaneous symmetrical components and its detection for positive and negative sequence current [J]. Proceedings of the CSEE, 2008, 28(1): 52-58
  • 18. Zhou Qing, Mao Ya-Hui, Zhao Yong-Bin. Improved harmonic detection method without PLL and LPF [J]. Electrical Measurement & Instrumentation, 2012, 49(554): 27-31